Q1Can you supply the SIEMENS 6AG2136-6CB00-1CA0?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the SIEMENS 6AG2136-6CB00-1CA0 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
6AG2136-6CB00-1CA0
Material Number
6ag21366cb001ca0
Manufacturer
SIEMENS
Product ID
1242768

Get a Free Quote

Request pricing and availability for 6AG2136-6CB00-1CA0.

More parts to source? Send your whole list in one enquiry

Key specifications

General information > Product type designation
F-TM Count 1x1Vpp sin/cos HF
Supply voltage > Rated value (DC)
24 V
Supply voltage > power supply according to NEC Class 2 required
No
Encoder supply > 5 V encoder supply > Output current, max.
300 mA
Encoder > Encoder signals, incremental encoder (symmetrical) > Input frequency, max.
200 kHz
Weights > Weight, approx.
42 g
See all specifications
6AG2136-6CB00-1CA0

Product Information

Technical Specifications

Specifications for 6AG2136-6CB00-1CA0

ParameterValue
General information > Product type designationF-TM Count 1x1Vpp sin/cos HF
General information > Firmware version > FW update possibleYes
General information > based on6ES7136-6CB00-0CA0
General information > usable BaseUnitsBU type A0
General information > Color code for module-specific color-coded labelCC01
General information > Product function > I&M dataYes; I&M0 to I&M3
General information > Engineering with > STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Supply voltage > Rated value (DC)24 V
Supply voltage > power supply according to NEC Class 2 requiredNo
Supply voltage > Load voltage L+ > Rated value (DC)24 V
Supply voltage > Load voltage L+ > permissible range, lower limit (DC)20.4 V
Supply voltage > Load voltage L+ > permissible range, upper limit (DC)28.8 V
Supply voltage > Load voltage L+ > Reverse polarity protectionYes
Input current > Current consumption, max.50 mA; without load, 150 mA with 300 mA encoder load
Encoder supply > 5 V encoder supply > 5 VYes; 5.1 V ±3.5 %
Encoder supply > 5 V encoder supply > Short-circuit protectionYes; Electronic overload protection; no protection on applying a normal or counter voltage.
Encoder supply > 5 V encoder supply > Output current, max.300 mA
Power loss > Power loss, typ.1.25 W
Address area > Address space per module > Inputs14 byte; S7-300/400F CPU, 13 byte
Address area > Address space per module > Outputs5 byte; S7-300/400F CPU, 4 byte
Hardware configuration > Automatic encodingYes
Hardware configuration > Electronic coding element type HYes
Digital inputs > Number of digital inputs1; (counter input)
Digital inputs > Digital inputs, parameterizableYes
Digital inputs > Digital input functions, parameterizable > Gate start/stopYes
Digital inputs > Digital input functions, parameterizable > Counter for incremental encoderYes
Digital inputs > Digital input functions, parameterizable > Number, max.1
Digital inputs > Input voltage > Type of input voltagesin/cos 1 Vpp
Digital inputs > Input delay (for rated value of input voltage) > Minimum pulse width for program reactions2.5 µs
Digital inputs > Input delay (for rated value of input voltage) > for technological functions > parameterizableYes
Digital inputs > Cable length > shielded, max.150 m
Encoder > Connectable encoders > Incremental encoder (symmetrical)Yes; up to 200 kHz depending on cable type and length
Encoder > Encoder signals, incremental encoder (symmetrical) > Input voltage1 Vpp, centered at 2.5 V offset
Encoder > Encoder signals, incremental encoder (symmetrical) > Input frequency, max.200 kHz
Encoder > Encoder signals, incremental encoder (symmetrical) > Counting frequency, max.800 kHz; with quadruple evaluation
Encoder > Encoder signals, incremental encoder (symmetrical) > Cable length, shielded, max.150 m
Encoder > Encoder signals, incremental encoder (symmetrical) > Incremental encoder with A/B tracks, 90° phase offsetYes; sin/cos
Encoder > Encoder signals, incremental encoder (symmetrical) > Incremental encoder with A/B tracks, 90° phase offset and zero trackYes; sin/cos/zero
Interfaces > Number of RS 485 interfaces0
Interrupts/diagnostics/status information > Diagnostics functionYes; see chapter "Diagnostic Messages" in the manual
Interrupts/diagnostics/status information > Alarms > Diagnostic alarmYes
Interrupts/diagnostics/status information > Alarms > Hardware interruptNo
Interrupts/diagnostics/status information > Diagnoses > Monitoring the supply voltageYes
Interrupts/diagnostics/status information > Diagnoses > Wire breakYes
Interrupts/diagnostics/status information > Diagnoses > Short-circuitYes
Interrupts/diagnostics/status information > Diagnoses > A/B transition error at incremental encoderYes
Interrupts/diagnostics/status information > Diagnostics indication LED > RUN LEDYes; green LED
Interrupts/diagnostics/status information > Diagnostics indication LED > ERROR LEDYes; red LED
Interrupts/diagnostics/status information > Diagnostics indication LED > Monitoring of the supply voltage (PWR-LED)Yes; green LED
Interrupts/diagnostics/status information > Diagnostics indication LED > Channel status displayYes; green LED
Interrupts/diagnostics/status information > Diagnostics indication LED > for channel diagnosticsYes; red LED
Interrupts/diagnostics/status information > Diagnostics indication LED > for module diagnosticsYes; green/red DIAG LED
Integrated Functions > CounterYes
Integrated Functions > Number of counters1
Integrated Functions > Counting frequency, max.800 kHz; with quadruple evaluation
Integrated Functions > Safety monitoring functions > Safe Operating Stop (SOS)Yes
Integrated Functions > Safety monitoring functions > Safely-Limited Speed (SLS)Yes
Integrated Functions > Safety monitoring functions > Safe Direction (SDI)Yes
Integrated Functions > Safety monitoring functions > Safe Speed Monitor (SSM)Yes
Integrated Functions > Counting functions > Continuous countingYes
Integrated Functions > Counting functions > Counter response parameterizableYes
Integrated Functions > Counting functions > Software gateYes
Integrated Functions > Counting functions > Counting range, parameterizableYes
Integrated Functions > Measuring functions > Measuring range > Frequency measurement, min.0.04 Hz
Integrated Functions > Measuring functions > Measuring range > Frequency measurement, max.800 kHz; with quadruple evaluation
Integrated Functions > Measuring functions > Measuring range > Cycle duration measurement, min.1 µs
Integrated Functions > Measuring functions > Measuring range > Cycle duration measurement, max.25 s
ParameterValue
Integrated Functions > Measuring functions > Measuring range > Velocity measurement, min.0 (speed in configured units per selected time basis - speed*1 000)
Integrated Functions > Measuring functions > Measuring range > Velocity measurement, max.2 147 483 (speed in configured units per selected time basis - speed*1 000)
Integrated Functions > Measuring functions > Accuracy > Frequency measurementup to 100 ppm; depending on measuring interval and signal evaluation; at low frequency external noise may have an effect on accuracy (reference the graph in 2.2.3)
Integrated Functions > Measuring functions > Accuracy > Cycle duration measurementup to 100 ppm; depending on measuring interval and signal evaluation; at low frequency external noise may have an effect on accuracy (reference the graph in 2.2.3)
Integrated Functions > Measuring functions > Accuracy > Velocity measurementup to 100 ppm; depending on measuring interval and signal evaluation; at low frequency external noise may have an effect on accuracy (reference the graph in 2.2.3)
Potential separation > Potential separation channels > between the channelsNo; Only one channel is available
Potential separation > Potential separation channels > between the channels and backplane busYes
Potential separation > Potential separation channels > Between the channels and load voltage L+No
Potential separation > Potential separation channels > between the channels and the power supply of the electronicsNo
Isolation > Isolation tested with750 V DC (type test) and according to EN 50155 (routine test)
Standards, approvals, certificates > Suitable for safety functionsYes
Standards, approvals, certificates > Ecological footprint > environmental product declarationYes
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (total) [CO2 eq]88.3 kg
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (during production) [CO2 eq]13.1 kg
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (during operation) [CO2 eq]76.6 kg
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (after end of life cycle) [CO2 eq]-1.37 kg
Standards, approvals, certificates > Highest safety class achievable in safety mode > Performance level according to ISO 13849-1Cat. 4, PLe
Standards, approvals, certificates > Highest safety class achievable in safety mode > SIL acc. to IEC 61508SIL 3
Standards, approvals, certificates > Highest safety class achievable in safety mode > SIL in accordance with EN 50126-1, 50129, 50159, 50716SIL 2; a higher safety integrity level is possible if tested and approved for the specific application under consideration of all local regulations.
Standards, approvals, certificates > Highest safety class achievable in safety mode > Probability of failure (for service life of 20 years and repair time of 100 hours) > low demand mode: PFDavg in accordance with SIL1< 2.00E-03 signal monitoring disabled
Standards, approvals, certificates > Highest safety class achievable in safety mode > Probability of failure (for service life of 20 years and repair time of 100 hours) > Low demand mode: PFDavg in accordance with SIL3< 3.00E-05
Standards, approvals, certificates > Highest safety class achievable in safety mode > Probability of failure (for service life of 20 years and repair time of 100 hours) > high demand/continuous mode: PFH in accordance with SIL1< 3.00E-08 1/h signal monitoring disabled
Standards, approvals, certificates > Highest safety class achievable in safety mode > Probability of failure (for service life of 20 years and repair time of 100 hours) > High demand/continuous mode: PFH in accordance with SIL3< 1.00E-09 1/h
Standards, approvals, certificates > Railway application > EN 50121-3-2Yes; EMC for rail vehicles
Standards, approvals, certificates > Railway application > EN 50121-4Yes; EMC for signal and telecommunications systems
Standards, approvals, certificates > Railway application > EN 50121-5Yes; EMC for fixed installations and railway power supply equipment
Standards, approvals, certificates > Railway application > EN 50124-1Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC
Standards, approvals, certificates > Railway application > EN 50125-1Yes; Rail vehicles - see ambient conditions
Standards, approvals, certificates > Railway application > EN 50125-2Yes; Stationary electrical equipment - see ambient conditions
Standards, approvals, certificates > Railway application > EN 50125-3Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)
Standards, approvals, certificates > Railway application > EN 50155Yes; Rail vehicles - temperature class OT1, ST1/ST2, horizontal mounting position
Standards, approvals, certificates > Railway application > EN 61373Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B
Standards, approvals, certificates > Railway application > Fire protection acc. to EN 45545-2Yes; For proof of conformity, see Service & Support
Ambient conditions > Ambient temperature during operation > horizontal installation, min.-25 °C; = Tmin (incl. condensation/frost)
Ambient conditions > Ambient temperature during operation > horizontal installation, max.60 °C; = Tmax; +70 °C for 10 min (OT1, ST1/ST2 acc. to EN 50155); +70 °C continuously with spacing modules (6AG2193-6BN00-4BA0) or configured empty slots to the left and right of the module (OT3, ST1/ST2 acc. to EN 50155)
Ambient conditions > Ambient temperature during operation > vertical installation, min.-25 °C; = Tmin
Ambient conditions > Ambient temperature during operation > vertical installation, max.55 °C; = Tmax
Ambient conditions > Altitude during operation relating to sea level > Installation altitude above sea level, max.2 000 m
Ambient conditions > Altitude during operation relating to sea level > Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Ambient conditions > Relative humidity > With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Ambient conditions > Resistance > Coolants and lubricants > Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Ambient conditions > Resistance > Use in stationary industrial systems > to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
Ambient conditions > Resistance > Use in stationary industrial systems > to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Ambient conditions > Resistance > Use in stationary industrial systems > to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Ambient conditions > Resistance > Use in stationary industrial systems > Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0//6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to biologically active substances according to EN 60721-3-5Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to chemically active substances according to EN 60721-3-5Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to mechanically active substances according to EN 60721-3-5Yes; Class 5S3 incl. sand, dust; *
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > Against mechanical environmental conditions acc. to EN 60721-3-5Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > against mechanical environmental conditions in agriculture acc. to ISO 15003Yes; Level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Usage in industrial process technology > Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Ambient conditions > Resistance > Usage in industrial process technology > Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Ambient conditions > Resistance > Remark > Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Ambient conditions > Conformal coating > Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Ambient conditions > Conformal coating > Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Ambient conditions > Conformal coating > Electronic equipment on rolling stock acc. to EN 50155Yes; class PC2 protective coating acc. to EN 50155
Ambient conditions > Conformal coating > Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Ambient conditions > Conformal coating > Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Dimensions > Width15 mm
Dimensions > Height73 mm
Dimensions > Depth58 mm
Weights > Weight, approx.42 g
Other > Note:for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776