Industrial Automation Parts. Prompt replies from real people.

SIEMENS 6AG2136-6DB01-2CA0 SIMATIC 6ES7 Controllers

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the SIEMENS 6AG2136-6DB01-2CA0?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the SIEMENS 6AG2136-6DB01-2CA0 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
6AG2136-6DB01-2CA0
Material Number
6ag21366db012ca0
Manufacturer
SIEMENS
Product ID
1242769

Get a Free Quote

Request pricing and availability for 6AG2136-6DB01-2CA0.

More parts to source? Send your whole list in one enquiry

Key specifications

General information > Product type designation
F-DQ 4x 24 V DC/2 A PM HF
Supply voltage > Rated value (DC)
24 V
Supply voltage > permissible range, lower limit (DC)
19.2 V
Power > Power consumption from the backplane bus
70 mW
Digital outputs > Output current > for signal "1" rated value
2 A
Weights > Weight, approx.
30 g
See all specifications
6AG2136-6DB01-2CA0

Product Information

Technical Specifications

Specifications for 6AG2136-6DB01-2CA0

ParameterValue
General information > Product type designationF-DQ 4x 24 V DC/2 A PM HF
General information > Firmware version > FW update possibleYes
General information > based on6ES7136-6DB01-0CA0
General information > usable BaseUnitsBU type A0
General information > Color code for module-specific color-coded labelCC01
General information > Product function > I&M dataYes; I&M0 to I&M3
General information > Engineering with > STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
CiR - Configuration in RUN > Reparameterization possible in RUNNo
Supply voltage > Rated value (DC)24 V
Supply voltage > permissible range, lower limit (DC)19.2 V
Supply voltage > permissible range, upper limit (DC)28.8 V
Supply voltage > Reverse polarity protectionYes
Supply voltage > power supply according to NEC Class 2 requiredNo
Input current > Current consumption (rated value)30 mA; without load
Input current > Current consumption, max.100 mA; without load
Output voltage > Rated value (DC)24 V
Power > Power consumption from the backplane bus70 mW
Power loss > Power loss, typ.3 W
Address area > Address space per module > Inputs6 byte; S7-300/400F CPU, 6 byte
Address area > Address space per module > Outputs6 byte; S7-300/400F CPU, 4 byte
Hardware configuration > Automatic encodingYes
Hardware configuration > Electronic coding element type FYes
Digital outputs > Type of digital outputTransistor
Digital outputs > Number of digital outputs4
Digital outputs > Digital outputs, parameterizableYes
Digital outputs > output type acc. to IEC 61131, type 2Yes
Digital outputs > Short-circuit protectionYes
Digital outputs > Response threshold, typ.> 3.3 A
Digital outputs > Open-circuit detectionYes
Digital outputs > Overload protectionYes
Digital outputs > Limitation of inductive shutdown voltage tosourcing output: -39 V DC in relation to 2M, sinking output: +47 V DC in relation to 2M
Digital outputs > Controlling a digital inputYes; digital output, according to IEC 61131-2, type 2
Digital outputs > Switching capacity of the outputs > with resistive load, max.2 A
Digital outputs > Switching capacity of the outputs > with inductive load, max.2 A
Digital outputs > Switching capacity of the outputs > on lamp load, max.10 W
Digital outputs > Load resistance range > lower limit12 Ω
Digital outputs > Load resistance range > upper limit2 000 Ω
Digital outputs > Output voltage > for signal "1", min.24 V; L+ (-0.5 V)
Digital outputs > Output current > for signal "1" rated value2 A
Digital outputs > Output current > for signal "0" residual current, max.0.5 mA
Digital outputs > Switching frequency > with resistive load, max.30 Hz; Symmetrical
Digital outputs > Switching frequency > with inductive load, max.0.1 Hz; according to IEC 60947-5-1, DC-13, symmetrical
Digital outputs > Switching frequency > with capacitive load, max.30 Hz; observe chapter "Switching of capacitive loads" in the manual
Digital outputs > Switching frequency > on lamp load, max.10 Hz; Symmetrical
Digital outputs > Total current of the outputs > Current per channel, max.2 A; note derating data in the manual
Digital outputs > Total current of the outputs > Current per module, max.6 A; note derating data in the manual
Digital outputs > Cable length > shielded, max.1 000 m
Digital outputs > Cable length > unshielded, max.500 m
Interrupts/diagnostics/status information > Diagnostics functionYes; See Chapter "Alarms/diagnostic messages" in the manual
Interrupts/diagnostics/status information > Substitute values connectableNo
Interrupts/diagnostics/status information > Alarms > Diagnostic alarmYes
Interrupts/diagnostics/status information > Alarms > Hardware interruptNo
Interrupts/diagnostics/status information > Diagnostics indication LED > RUN LEDYes; green LED
Interrupts/diagnostics/status information > Diagnostics indication LED > ERROR LEDYes; red LED
Interrupts/diagnostics/status information > Diagnostics indication LED > Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Interrupts/diagnostics/status information > Diagnostics indication LED > Channel status displayYes; green LED
Interrupts/diagnostics/status information > Diagnostics indication LED > for channel diagnosticsYes; red LED
Interrupts/diagnostics/status information > Diagnostics indication LED > for module diagnosticsYes; green/red DIAG LED
Potential separation > Potential separation channels > between the channelsNo
ParameterValue
Potential separation > Potential separation channels > between the channels and backplane busYes
Potential separation > Potential separation channels > between the channels and the power supply of the electronicsNo
Isolation > Isolation tested with750 V DC (type test) and according to EN 50155 (routine test)
Standards, approvals, certificates > Siemens Eco Profile (SEP)Siemens EcoTech
Standards, approvals, certificates > Suitable for safety functionsYes
Standards, approvals, certificates > Ecological footprint > environmental product declarationYes; type II acc. to ISO 14021
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (total) [CO2 eq]52 kg
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (during production) [CO2 eq]6.8 kg
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (during operation) [CO2 eq]45.8 kg
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (after end of life cycle) [CO2 eq]-0.628 kg
Standards, approvals, certificates > Highest safety class achievable in safety mode > Performance level according to ISO 13849-1PLe
Standards, approvals, certificates > Highest safety class achievable in safety mode > Category according to ISO 13849-1Cat. 4
Standards, approvals, certificates > Highest safety class achievable in safety mode > SIL acc. to IEC 61508SIL 3
Standards, approvals, certificates > Highest safety class achievable in safety mode > SIL in accordance with EN 50126-1, 50129, 50159, 50716SIL 2; a higher safety integrity level is possible if tested and approved for the specific application under consideration of all local regulations.
Standards, approvals, certificates > Highest safety class achievable in safety mode > Probability of failure (for service life of 20 years and repair time of 100 hours) > Low demand mode: PFDavg in accordance with SIL2< 2.00E-04
Standards, approvals, certificates > Highest safety class achievable in safety mode > Probability of failure (for service life of 20 years and repair time of 100 hours) > Low demand mode: PFDavg in accordance with SIL3< 2.00E-05
Standards, approvals, certificates > Highest safety class achievable in safety mode > Probability of failure (for service life of 20 years and repair time of 100 hours) > High demand/continuous mode: PFH in accordance with SIL2< 1.00E-08 1/h
Standards, approvals, certificates > Highest safety class achievable in safety mode > Probability of failure (for service life of 20 years and repair time of 100 hours) > High demand/continuous mode: PFH in accordance with SIL3< 1.00E-09 1/h
Standards, approvals, certificates > Railway application > EN 50121-3-2Yes; EMC for rail vehicles
Standards, approvals, certificates > Railway application > EN 50121-4Yes; EMC for signal and telecommunications systems
Standards, approvals, certificates > Railway application > EN 50121-5Yes; EMC for fixed installations and railway power supply equipment (shielded cables required)
Standards, approvals, certificates > Railway application > EN 50124-1Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC
Standards, approvals, certificates > Railway application > EN 50125-1Yes; Rail vehicles - see ambient conditions
Standards, approvals, certificates > Railway application > EN 50125-2Yes; Stationary electrical equipment - see ambient conditions
Standards, approvals, certificates > Railway application > EN 50125-3Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)
Standards, approvals, certificates > Railway application > EN 50155Yes; Rail vehicles - temperature class OT2, ST1/ST2, horizontal mounting position
Standards, approvals, certificates > Railway application > EN 61373Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B
Standards, approvals, certificates > Railway application > Fire protection acc. to EN 45545-2Yes; For proof of conformity, see Service & Support
Ambient conditions > Ambient temperature during operation > horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
Ambient conditions > Ambient temperature during operation > horizontal installation, max.60 °C; = Tmax; +70 °C for 10 min (OT2, ST1/ST2 acc. to EN 50155); +70 °C continuously/+85 °C for 10 min with spacing modules (6AG2193-6BN00-4BA0) or configured slots to the left and right of the module (OT4, ST1/ST2 acc. to EN 50155)
Ambient conditions > Ambient temperature during operation > vertical installation, min.-40 °C; = Tmin
Ambient conditions > Ambient temperature during operation > vertical installation, max.50 °C; = Tmax
Ambient conditions > Altitude during operation relating to sea level > Installation altitude above sea level, max.2 000 m
Ambient conditions > Altitude during operation relating to sea level > Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Ambient conditions > Relative humidity > With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Ambient conditions > Resistance > Coolants and lubricants > Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Ambient conditions > Resistance > Use in stationary industrial systems > to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
Ambient conditions > Resistance > Use in stationary industrial systems > to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75%) incl. salt spray acc. to EN 60068-2-52 (severity degree 3)
Ambient conditions > Resistance > Use in stationary industrial systems > to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust
Ambient conditions > Resistance > Use in stationary industrial systems > Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0//6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to biologically active substances according to EN 60721-3-5Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to chemically active substances according to EN 60721-3-5Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3)
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to mechanically active substances according to EN 60721-3-5Yes; Class 5S3 incl. sand, dust
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > Against mechanical environmental conditions acc. to EN 60721-3-5Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > against mechanical environmental conditions in agriculture acc. to ISO 15003Yes; Level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Usage in industrial process technology > Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Ambient conditions > Resistance > Usage in industrial process technology > Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Ambient conditions > Conformal coating > Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Ambient conditions > Conformal coating > Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Ambient conditions > Conformal coating > Electronic equipment on rolling stock acc. to EN 50155Yes; class PC2 protective coating acc. to EN 50155
Ambient conditions > Conformal coating > Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Ambient conditions > Conformal coating > Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Dimensions > Width15 mm
Dimensions > Height73 mm
Dimensions > Depth58 mm
Weights > Weight, approx.30 g
Other > Note:for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?