Product Model
6AG2155-6AA02-4BN0
Material Number
6ag21556aa024bn0
Manufacturer
SIEMENS
Product ID
1242773

Get a Free Quote

Request pricing and availability for 6AG2155-6AA02-4BN0.

More parts to source? Send your whole list in one enquiry

Key specifications

General information > Product type designation
IM 155-6 PN ST incl. BA 2x RJ45 and server module
Supply voltage > Rated value (DC)
24 V
Supply voltage > permissible range, lower limit (DC)
19.2 V
Supply voltage > Reverse polarity protection
Yes
Ambient conditions > Ambient temperature during operation > horizontal installation, min.
-40 °C; = Tmin (incl. condensation/frost)
Weights > Weight, approx.
125 g; without BusAdapter
See all specifications
6AG2155-6AA02-4BN0

Product Information

Technical Specifications

Specifications for 6AG2155-6AA02-4BN0

ParameterValue
General information > Product type designationIM 155-6 PN ST incl. BA 2x RJ45 and server module
General information > Firmware version > FW update possibleYes
General information > Vendor identification (VendorID)002AH
General information > Device identifier (DeviceID)0313H
General information > Manufacturer ID according to ODVA (VendorID)04E3H
General information > Device ID according to ODVA (Product code)0FA2H
General information > based on6ES7155-6AA02-0BN0
General information > Product function > I&M dataYes; I&M0 to I&M4
General information > Product function > Module swapping during operation (hot swapping)Yes; Multi-hot swapping
General information > Product function > Isochronous modeNo
General information > Product function > IRTYes
General information > Product function > Local coupling, IO data > Number of coupling modules6; 1x output + max. 5x input
General information > Engineering with > STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Configuration control > via datasetYes
Supply voltage > Rated value (DC)24 V
Supply voltage > permissible range, lower limit (DC)19.2 V
Supply voltage > permissible range, upper limit (DC)28.8 V
Supply voltage > Reverse polarity protectionYes
Supply voltage > Short-circuit protectionYes
Supply voltage > Mains buffering > Mains/voltage failure stored energy time10 ms
Input current > Current consumption (rated value)350 mA
Input current > Current consumption, max.450 mA
Input current > Inrush current, max.1 A
Input current > I²t0.05 A²·s
Power loss > Power loss, typ.1.8 W
Address area > Address space per module > Address space per module, max.288 byte; For input and output data respectively
Address area > Address space per station > Address space per station, max.1 440 byte
Hardware configuration > Rack > Quantity of operable ET 200SP modules, max.32
Hardware configuration > Rack > Quantity of operable ET 200AL modules, max.16
Hardware configuration > Submodules > Number of submodules per station, max.256
Interfaces > Number of PROFINET interfaces1; 2 ports (switch)
1. Interface > Interface types > RJ 45 (Ethernet)Yes; with BusAdapter
1. Interface > Interface types > Number of ports2; with BusAdapter
1. Interface > Interface types > integrated switchYes
1. Interface > Interface types > BusAdapter (PROFINET)Yes
1. Interface > Protocols > PROFINET IO DeviceYes
1. Interface > Protocols > Open IE communicationYes
1. Interface > Protocols > Media redundancyYes; PROFINET MRP client
1. Interface > PROFINET IO Device > Services > IRTYes; 1 ms to 4 ms at an interval of 125 µs
1. Interface > PROFINET IO Device > Services > Dynamic Frame Packing (DFP)Yes
1. Interface > PROFINET IO Device > Services > Fast ForwardingYes
1. Interface > PROFINET IO Device > Services > FragmentationYes
1. Interface > PROFINET IO Device > Services > PROFIenergyYes
1. Interface > PROFINET IO Device > Services > Prioritized startupYes
1. Interface > PROFINET IO Device > Services > Shared deviceYes
1. Interface > PROFINET IO Device > Services > Number of IO Controllers with shared device, max.4
Interface types > RJ 45 (Ethernet) > Transmission procedurePROFINET with 100 Mbit/s full duplex (100BASE-TX)
Interface types > RJ 45 (Ethernet) > 100 MbpsYes
Interface types > RJ 45 (Ethernet) > AutonegotiationYes
Interface types > RJ 45 (Ethernet) > AutocrossingYes
Protocols > Supports protocol for PROFINET IOYes
Protocols > PROFIsafeYes
Protocols > PROFIBUSNo
Protocols > EtherNet/IPNo
Protocols > Modbus TCPNo
Protocols > Redundancy mode > PROFINET system redundancy (S2)No
Protocols > Redundancy mode > Media redundancy > MRPYes
Protocols > Redundancy mode > Media redundancy > MRPDNo
Protocols > Open IE communication > TCP/IPYes
Protocols > Open IE communication > UDPYes
Protocols > Open IE communication > SNMPYes
Protocols > Open IE communication > LLDPYes
Protocols > Open IE communication > ARPYes
Protocols > Open IE communication > IGMPYes
Protocols > Open IE communication > MulticastYes
Protocols > Open IE communication > BroadcastYes
Protocols > Open IE communication > IPv4Yes
ParameterValue
Protocols > Open IE communication > IPv6No
Interrupts/diagnostics/status information > Status indicatorYes
Interrupts/diagnostics/status information > AlarmsYes
Interrupts/diagnostics/status information > Diagnostics functionYes
Interrupts/diagnostics/status information > Diagnostics indication LED > RUN LEDYes; green LED
Interrupts/diagnostics/status information > Diagnostics indication LED > ERROR LEDYes; red LED
Interrupts/diagnostics/status information > Diagnostics indication LED > MAINT LEDYes; Yellow LED
Interrupts/diagnostics/status information > Diagnostics indication LED > Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Interrupts/diagnostics/status information > Diagnostics indication LED > Connection display LINK TX/RXYes; 2x green link LEDs on BusAdapter
Potential separation > between backplane bus and electronicsNo
Potential separation > between PROFINET and all other circuitsYes; 1500 V AC (type test)
Potential separation > between supply and all other circuitsNo
Permissible potential difference > between different circuitsSafety extra low voltage SELV
Isolation > Isolation tested with750 V DC (type test) and according to EN 50155 (routine test)
Standards, approvals, certificates > Network loading class3
Standards, approvals, certificates > Railway application > EN 50121-3-2Yes; EMC for rail vehicles
Standards, approvals, certificates > Railway application > EN 50121-4Yes; EMC for signal and telecommunications systems
Standards, approvals, certificates > Railway application > EN 50121-5Yes; EMC for fixed installations and railway power supply equipment
Standards, approvals, certificates > Railway application > EN 50124-1Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV
Standards, approvals, certificates > Railway application > EN 50125-1Yes; Rail vehicles - see ambient conditions
Standards, approvals, certificates > Railway application > EN 50125-2Yes; Stationary electrical equipment - see ambient conditions
Standards, approvals, certificates > Railway application > EN 50125-3Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)
Standards, approvals, certificates > Railway application > EN 50155Yes; Rail vehicles - temperature class OT4, ST1/ST2, horizontal mounting position
Standards, approvals, certificates > Railway application > EN 61373Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B
Standards, approvals, certificates > Railway application > Fire protection acc. to EN 45545-2Yes; For proof of conformity, see Service & Support
Security > PROFINET Security Class1
Security > signed firmware updateYes
Security > safely removing dataYes
Security > data integrityYes
Ambient conditions > Ambient temperature during operation > horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
Ambient conditions > Ambient temperature during operation > horizontal installation, max.70 °C; = Tmax; +85 °C for 10 min (OT4, ST1/ST2 acc. to EN 50155)
Ambient conditions > Ambient temperature during operation > vertical installation, min.-40 °C; = Tmin
Ambient conditions > Ambient temperature during operation > vertical installation, max.50 °C; = Tmax
Ambient conditions > Altitude during operation relating to sea level > Installation altitude above sea level, max.2 000 m
Ambient conditions > Altitude during operation relating to sea level > Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Ambient conditions > Relative humidity > With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Ambient conditions > Resistance > Coolants and lubricants > Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Ambient conditions > Resistance > Use in stationary industrial systems > to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
Ambient conditions > Resistance > Use in stationary industrial systems > to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Ambient conditions > Resistance > Use in stationary industrial systems > to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Ambient conditions > Resistance > Use in stationary industrial systems > Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0//6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to biologically active substances according to EN 60721-3-5Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to chemically active substances according to EN 60721-3-5Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to mechanically active substances according to EN 60721-3-5Yes; Class 5S3 incl. sand, dust; *
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > Against mechanical environmental conditions acc. to EN 60721-3-5Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > against mechanical environmental conditions in agriculture acc. to ISO 15003Yes; Level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Use on ships/at sea > to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna)
Ambient conditions > Resistance > Use on ships/at sea > to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Ambient conditions > Resistance > Use on ships/at sea > to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Ambient conditions > Resistance > Use on ships/at sea > Against mechanical environmental conditions acc. to EN 60721-3-6Yes; class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Usage in industrial process technology > Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Ambient conditions > Resistance > Usage in industrial process technology > Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Ambient conditions > Resistance > Remark > Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Ambient conditions > Conformal coating > Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Ambient conditions > Conformal coating > Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Ambient conditions > Conformal coating > Electronic equipment on rolling stock acc. to EN 50155Yes; class PC2 protective coating acc. to EN 50155
Ambient conditions > Conformal coating > Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Ambient conditions > Conformal coating > Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Connection method > ET-Connection > via BU/BA SendYes; + 16 ET 200AL modules
Mechanics/material > Strain reliefYes; Optional
Dimensions > Width50 mm
Dimensions > Height117 mm
Dimensions > Depth74 mm
Weights > Weight, approx.125 g; without BusAdapter