Industrial Automation Parts. Prompt replies from real people.

SIEMENS 6AG2137-6EA00-2BA0 SIMATIC 6ES7 Controllers

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the SIEMENS 6AG2137-6EA00-2BA0?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the SIEMENS 6AG2137-6EA00-2BA0 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
6AG2137-6EA00-2BA0
Material Number
6ag21376ea002ba0
Manufacturer
SIEMENS
Product ID
1242770

Get a Free Quote

Request pricing and availability for 6AG2137-6EA00-2BA0.

More parts to source? Send your whole list in one enquiry

Key specifications

General information > Product type designation
CM 1x CAN ST
Supply voltage > Rated value (DC)
24 V
Supply voltage > permissible range, lower limit (DC)
19.2 V
Supply voltage > Reverse polarity protection
Yes
Ambient conditions > Ambient temperature during operation > horizontal installation, min.
-40 °C; = Tmin (incl. condensation/frost)
Weights > Weight, approx.
32 g
See all specifications
6AG2137-6EA00-2BA0

Product Information

Technical Specifications

Specifications for 6AG2137-6EA00-2BA0

ParameterValue
General information > Product type designationCM 1x CAN ST
General information > Firmware version > FW update possibleYes
General information > based on6ES7137-6EA00-0BA0
General information > usable BaseUnitsBU type A0
General information > Color code for module-specific color-coded labelCC00
General information > Product function > I&M dataYes; I&M0 to I&M3
General information > Product function > Module swapping during operation (hot swapping)Yes
General information > Product function > Isochronous modeNo
General information > Engineering with > STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Supply voltage > Rated value (DC)24 V
Supply voltage > permissible range, lower limit (DC)19.2 V
Supply voltage > permissible range, upper limit (DC)28.8 V
Supply voltage > Reverse polarity protectionYes
Input current > Current consumption, typ.20 mA
Input current > Current consumption, max.25 mA
Power loss > Power loss, typ.0.5 W
Address area > Address space per module > Address space per module, max.256 byte
1. Interface > Interface typeCAN according to CiA 303-1
1. Interface > IsolatedYes; 500 V AC or 707 V DC
1. Interface > Interface types > Number of ports1
1. Interface > Interface types > Design of the connectionPush-in terminal
1. Interface > CAN > CAN operating modesCAN Standard CAN 2.0A/B; CANopen Manager / Slave acc. to CiA
1. Interface > CAN > Specification acc. to CiACiA 301 & CiA 302
1. Interface > CAN > Transmission rate, min.10 kbit/s
1. Interface > CAN > Transmission rate, max.1 000 kbit/s
1. Interface > CAN > max. number of devices60
1. Interface > CAN > Number of SDOs in parallel16; Parallel
1. Interface > CAN > Number of PDOs128; Send / receive
1. Interface > CAN > Services > Node/life-guardingYes
1. Interface > CAN > Services > HeartbeatYes
1. Interface > CAN > Services > SYNCYes
Interrupts/diagnostics/status information > AlarmsYes
Interrupts/diagnostics/status information > Diagnostics functionYes
Interrupts/diagnostics/status information > Diagnostics indication LED > RUN LEDYes
Interrupts/diagnostics/status information > Diagnostics indication LED > ERROR LEDYes
Interrupts/diagnostics/status information > Diagnostics indication LED > MAINT LEDNo
Interrupts/diagnostics/status information > Diagnostics indication LED > Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Potential separation > between backplane bus and interfaceYes
Isolation > Isolation tested with750 V DC (type test) and according to EN 50155 (routine test)
Standards, approvals, certificates > Ecological footprint > environmental product declarationYes
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (total) [CO2 eq]25.2 kg
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (during production) [CO2 eq]6.15 kg
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (during operation) [CO2 eq]19.4 kg
Standards, approvals, certificates > Ecological footprint > Global warming potential > global warming potential, (after end of life cycle) [CO2 eq]-0.289 kg
Standards, approvals, certificates > Railway application > EN 50121-3-2Yes; EMC for rail vehicles
Standards, approvals, certificates > Railway application > EN 50121-4Yes; EMC for signal and telecommunications systems
Standards, approvals, certificates > Railway application > EN 50121-5Yes; EMC for fixed installations and railway power supply equipment (shielded cables required)
ParameterValue
Standards, approvals, certificates > Railway application > EN 50124-1Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC
Standards, approvals, certificates > Railway application > EN 50125-1Yes; Rail vehicles - see ambient conditions
Standards, approvals, certificates > Railway application > EN 50125-2Yes; Stationary electrical equipment - see ambient conditions
Standards, approvals, certificates > Railway application > EN 50125-3Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)
Standards, approvals, certificates > Railway application > EN 50155Yes; Rail vehicles - temperature class OT2, ST1/ST2, horizontal mounting position
Standards, approvals, certificates > Railway application > EN 61373Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B
Standards, approvals, certificates > Railway application > Fire protection acc. to EN 45545-2Yes; For proof of conformity, see Service & Support
Ambient conditions > Ambient temperature during operation > horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
Ambient conditions > Ambient temperature during operation > horizontal installation, max.60 °C; = Tmax; +70 °C for 10 min (OT2, ST1/ST2 acc. to EN 50155); +70 °C continuously with spacing modules (6AG2193-6BN00-4BA0) or configured slots to the left and right of the module (OT4, ST0 acc. to EN 50155)
Ambient conditions > Ambient temperature during operation > vertical installation, min.-40 °C; = Tmin
Ambient conditions > Ambient temperature during operation > vertical installation, max.50 °C; = Tmax
Ambient conditions > Ambient temperature during operation > ceiling installation, min.-40 °C; = Tmin
Ambient conditions > Ambient temperature during operation > ceiling installation, max.50 °C; = Tmax
Ambient conditions > Ambient temperature during operation > floor installation, min.-40 °C; = Tmin
Ambient conditions > Ambient temperature during operation > floor installation, max.50 °C; = Tmax
Ambient conditions > Altitude during operation relating to sea level > Installation altitude above sea level, max.2 000 m
Ambient conditions > Altitude during operation relating to sea level > Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Ambient conditions > Relative humidity > With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Ambient conditions > Resistance > Coolants and lubricants > Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Ambient conditions > Resistance > Use in stationary industrial systems > to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
Ambient conditions > Resistance > Use in stationary industrial systems > to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Ambient conditions > Resistance > Use in stationary industrial systems > to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Ambient conditions > Resistance > Use in stationary industrial systems > Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to biologically active substances according to EN 60721-3-5Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to chemically active substances according to EN 60721-3-5Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to mechanically active substances according to EN 60721-3-5Yes; Class 5S3 incl. sand, dust; *
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > Against mechanical environmental conditions acc. to EN 60721-3-5Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > against mechanical environmental conditions in agriculture acc. to ISO 15003Yes; level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Ambient conditions > Resistance > Usage in industrial process technology > Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Ambient conditions > Resistance > Usage in industrial process technology > Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Ambient conditions > Resistance > Remark > Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Ambient conditions > Conformal coating > Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Ambient conditions > Conformal coating > Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Ambient conditions > Conformal coating > Electronic equipment on rolling stock acc. to EN 50155Yes; Class PC2 protective coating acc. to EN 50155:2017
Ambient conditions > Conformal coating > Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Ambient conditions > Conformal coating > Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Decentralized operation > to SIMATIC S7-300No
Decentralized operation > to SIMATIC S7-400No
Decentralized operation > to SIMATIC S7-1200Yes
Decentralized operation > to SIMATIC S7-1500Yes
Dimensions > Width15 mm
Dimensions > Height73 mm
Dimensions > Depth58 mm
Weights > Weight, approx.32 g
Other > Note:for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp