Industrial Automation Parts. Prompt replies from real people.

SIEMENS 6AG2138-6BA01-2BA0 SIMATIC 6ES7 Controllers

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the SIEMENS 6AG2138-6BA01-2BA0?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the SIEMENS 6AG2138-6BA01-2BA0 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
6AG2138-6BA01-2BA0
Material Number
6ag21386ba012ba0
Manufacturer
SIEMENS
Product ID
1242771

Get a Free Quote

Request pricing and availability for 6AG2138-6BA01-2BA0.

More parts to source? Send your whole list in one enquiry

Key specifications

General information > Product type designation
TM PosInput 1
Supply voltage > Rated value (DC)
24 V
Supply voltage > Load voltage L+ > Rated value (DC)
24 V
Encoder supply > 5 V encoder supply > Output current, max.
300 mA; Total current of all encoders
Digital outputs > Switching frequency > with resistive load, max.
10 kHz
Weights > Weight, approx.
45 g
See all specifications
6AG2138-6BA01-2BA0

Product Information

Technical Specifications

Specifications for 6AG2138-6BA01-2BA0

ParameterValue
General information > Product type designationTM PosInput 1
General information > Firmware version > FW update possibleYes
General information > based on6ES7138-6BA01-0BA0
General information > usable BaseUnitsBU type A0
General information > Color code for module-specific color-coded labelCC00
General information > Product function > I&M dataYes; I&M0 to I&M3
General information > Product function > Isochronous modeYes
General information > Engineering with > STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Supply voltage > Rated value (DC)24 V
Supply voltage > Load voltage L+ > Rated value (DC)24 V
Supply voltage > Load voltage L+ > permissible range, lower limit (DC)19.2 V
Supply voltage > Load voltage L+ > permissible range, upper limit (DC)28.8 V
Supply voltage > Load voltage L+ > Reverse polarity protectionYes
Input current > Current consumption, max.75 mA; without load
Encoder supply > Number of outputs2
Encoder supply > 5 V encoder supply > 5 VYes
Encoder supply > 5 V encoder supply > Short-circuit protectionYes; electronic/thermal
Encoder supply > 5 V encoder supply > Output current, max.300 mA; Total current of all encoders
Encoder supply > 24 V encoder supply > 24 VYes; L+ (-0.8 V)
Encoder supply > 24 V encoder supply > Short-circuit protectionYes; electronic/thermal
Encoder supply > 24 V encoder supply > Output current, max.300 mA; Total current of all encoders
Power loss > Power loss, typ.1.5 W
Address area > Address space per module > Inputs16 byte; 4 bytes in Fast mode
Address area > Address space per module > Outputs12 byte; 4 bytes for Motion Control, 0 bytes for Fast mode
Hardware configuration > Automatic encodingYes
Hardware configuration > Mechanical coding elementYes
Hardware configuration > Type of mechanical coding elementtype B
Digital inputs > Number of digital inputs2
Digital inputs > Digital inputs, parameterizableYes
Digital inputs > Input characteristic curve in accordance with IEC 61131, type 3Yes
Digital inputs > Digital input functions, parameterizable > Gate start/stopYes; only for pulse and incremental encoders
Digital inputs > Digital input functions, parameterizable > CaptureYes
Digital inputs > Digital input functions, parameterizable > SynchronizationYes; only for pulse and incremental encoders
Digital inputs > Digital input functions, parameterizable > Freely usable digital inputYes
Digital inputs > Input voltage > Rated value (DC)24 V
Digital inputs > Input voltage > for signal "0"-5 ... +5 V
Digital inputs > Input voltage > for signal "1"+11 to +30V
Digital inputs > Input voltage > permissible voltage at input, min.-30 V; -5 V continuous, -30 V brief reverse polarity protection
Digital inputs > Input voltage > permissible voltage at input, max.30 V
Digital inputs > Input current > for signal "1", typ.2.5 mA
Digital inputs > Input delay (for rated value of input voltage) > for standard inputs > parameterizableYes; none0.050.10.40.81.63.212.820 ms
Digital inputs > Input delay (for rated value of input voltage) > for technological functions > parameterizableYes
Digital inputs > Cable length > shielded, max.1 000 m
Digital inputs > Cable length > unshielded, max.600 m
Digital outputs > Type of digital outputTransistor
Digital outputs > Number of digital outputs2
Digital outputs > Digital outputs, parameterizableYes
Digital outputs > Short-circuit protectionYes; electronic/thermal
Digital outputs > Response threshold, typ.1 A
Digital outputs > Limitation of inductive shutdown voltage toL+ (-53 V)
Digital outputs > Controlling a digital inputYes
Digital outputs > Digital output functions, parameterizable > Switching tripped by comparison valuesYes
Digital outputs > Digital output functions, parameterizable > Freely usable digital outputYes
Digital outputs > Switching capacity of the outputs > with resistive load, max.0.5 A; Per digital output
Digital outputs > Switching capacity of the outputs > on lamp load, max.5 W
Digital outputs > Load resistance range > lower limit48 Ω
Digital outputs > Load resistance range > upper limit12 kΩ
Digital outputs > Output voltage > for signal "1", min.23.2 V; L+ (-0.8 V)
Digital outputs > Output current > for signal "1" rated value0.5 A; Per digital output
Digital outputs > Output current > for signal "1" permissible range, max.0.6 A; Per digital output
Digital outputs > Output current > for signal "1" minimum load current2 mA
Digital outputs > Output current > for signal "0" residual current, max.0.5 mA
Digital outputs > Output delay with resistive load > "0" to "1", max.50 µs
Digital outputs > Output delay with resistive load > "1" to "0", max.50 µs
Digital outputs > Switching frequency > with resistive load, max.10 kHz
Digital outputs > Switching frequency > with inductive load, max.0.5 Hz; Acc. to IEC 60947-5-1, DC-13; observe derating curve
Digital outputs > Switching frequency > on lamp load, max.10 Hz
Digital outputs > Total current of the outputs > Current per module, max.1 A
Digital outputs > Cable length > shielded, max.1 000 m
Digital outputs > Cable length > unshielded, max.600 m
Encoder > Encoder signals, incremental encoder (symmetrical) > Input voltageRS 422
Encoder > Encoder signals, incremental encoder (symmetrical) > Input frequency, max.1 MHz
Encoder > Encoder signals, incremental encoder (symmetrical) > Counting frequency, max.4 MHz; with quadruple evaluation
Encoder > Encoder signals, incremental encoder (symmetrical) > Cable length, shielded, max.32 m; at 1 MHz
Encoder > Encoder signals, incremental encoder (symmetrical) > Signal filter, parameterizableYes
Encoder > Encoder signals, incremental encoder (symmetrical) > Incremental encoder with A/B tracks, 90° phase offsetYes
Encoder > Encoder signals, incremental encoder (symmetrical) > Incremental encoder with A/B tracks, 90° phase offset and zero trackYes
Encoder > Encoder signals, incremental encoder (symmetrical) > pulse encoderYes
Encoder > Encoder signals, incremental encoder (symmetrical) > Pulse encoder with directionYes
Encoder > Encoder signals, incremental encoder (symmetrical) > pulse encoder with one impulse signal per count directionYes
Encoder > Encoder signals, incremental encoder (asymmetrical) > Input voltage5 V TTL (push-pull encoders only)
Encoder > Encoder signals, incremental encoder (asymmetrical) > Input frequency, max.1 MHz
Encoder > Encoder signals, incremental encoder (asymmetrical) > Counting frequency, max.4 MHz; with quadruple evaluation
Encoder > Encoder signals, incremental encoder (asymmetrical) > Signal filter, parameterizableYes
Encoder > Encoder signals, incremental encoder (asymmetrical) > Incremental encoder with A/B tracks, 90° phase offsetYes
Encoder > Encoder signals, incremental encoder (asymmetrical) > Incremental encoder with A/B tracks, 90° phase offset and zero trackYes
Encoder > Encoder signals, incremental encoder (asymmetrical) > pulse encoderYes
Encoder > Encoder signals, incremental encoder (asymmetrical) > pulse encoder with directionYes
Encoder > Encoder signals, incremental encoder (asymmetrical) > pulse encoder with one impulse signal per count directionYes
Encoder > Encoder signals, absolute encoder (SSI) > Input signalto RS-422
Encoder > Encoder signals, absolute encoder (SSI) > Telegram length, parameterizable10 ... 40 bit
Encoder > Encoder signals, absolute encoder (SSI) > Clock frequency, max.2 MHz; 125 kHz, 250 kHz, 500 kHz, 1 MHz, 1.5 MHz or 2 MHz
Encoder > Encoder signals, absolute encoder (SSI) > Binary codeYes
Encoder > Encoder signals, absolute encoder (SSI) > Gray codeYes
Encoder > Encoder signals, absolute encoder (SSI) > Cable length, shielded, max.320 m; Cable length, RS-422 SSI absolute encoders, Siemens type 6FX2001-5, 24 V supply: 125 kHz, 320 meters shielded, max.; 250 kHz, 160 meters shielded, max.; 500 kHz, 60 meters shielded, max.; 1 MHz, 20 meters shielded, max. 1.5 MHz, 10 meters shielded, max.; 2 MHz, 8 meters shielded, max.
Encoder > Encoder signals, absolute encoder (SSI) > Parity bit, parameterizableYes
Encoder > Encoder signals, absolute encoder (SSI) > Monoflop time16, 32, 48, 64 µs & automatic
ParameterValue
Encoder > Encoder signals, absolute encoder (SSI) > MultiturnYes
Encoder > Encoder signals, absolute encoder (SSI) > SingleturnYes
Encoder > Interface types > TTL 5 VYes; push-pull encoders only
Encoder > Interface types > RS 422Yes
Interfaces > Number of RS 485 interfaces0
Interrupts/diagnostics/status information > Substitute values connectableYes; Parameterizable
Interrupts/diagnostics/status information > Alarms > Diagnostic alarmYes
Interrupts/diagnostics/status information > Alarms > Hardware interruptYes
Interrupts/diagnostics/status information > Diagnoses > Monitoring the supply voltageYes
Interrupts/diagnostics/status information > Diagnoses > Wire breakYes
Interrupts/diagnostics/status information > Diagnoses > Short-circuitYes
Interrupts/diagnostics/status information > Diagnoses > A/B transition error at incremental encoderYes
Interrupts/diagnostics/status information > Diagnoses > Telegram error at SSI encoderYes
Interrupts/diagnostics/status information > Diagnoses > Group errorYes
Interrupts/diagnostics/status information > Diagnostics indication LED > Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Interrupts/diagnostics/status information > Diagnostics indication LED > Channel status displayYes; green LED
Interrupts/diagnostics/status information > Diagnostics indication LED > for module diagnosticsYes; green/red DIAG LED
Interrupts/diagnostics/status information > Diagnostics indication LED > Status indicator forward counting (green)Yes
Interrupts/diagnostics/status information > Diagnostics indication LED > Status indicator backward counting (green)Yes
Integrated Functions > CounterYes
Integrated Functions > Number of counters1
Integrated Functions > Counting frequency, max.4 MHz; with quadruple evaluation
Integrated Functions > Fast modeYes
Integrated Functions > Counting functions > Can be used with TO High_Speed_CounterYes; only for pulse and incremental encoders
Integrated Functions > Counting functions > Continuous countingYes
Integrated Functions > Counting functions > Counter response parameterizableYes
Integrated Functions > Counting functions > Hardware gate via digital inputYes
Integrated Functions > Counting functions > Software gateYes
Integrated Functions > Counting functions > Event-controlled stopYes
Integrated Functions > Counting functions > Synchronization via digital inputYes
Integrated Functions > Counting functions > Counting range, parameterizableYes
Integrated Functions > Counting functions > Comparator > Number of comparators2
Integrated Functions > Counting functions > Comparator > Direction dependencyYes
Integrated Functions > Counting functions > Comparator > Can be changed from user programYes
Integrated Functions > Position detection > Incremental acquisitionYes
Integrated Functions > Position detection > Absolute acquisitionYes
Integrated Functions > Position detection > Suitable for S7-1500 Motion ControlYes
Integrated Functions > Measuring functions > Measuring time, parameterizableYes
Integrated Functions > Measuring functions > Dynamic measurement period adjustmentYes
Integrated Functions > Measuring functions > Number of thresholds, parameterizable2
Integrated Functions > Measuring functions > Measuring range > Frequency measurement, min.0.04 Hz
Integrated Functions > Measuring functions > Measuring range > Frequency measurement, max.4 MHz
Integrated Functions > Measuring functions > Measuring range > Cycle duration measurement, min.0.25 µs
Integrated Functions > Measuring functions > Measuring range > Cycle duration measurement, max.25 s
Integrated Functions > Measuring functions > Accuracy > Frequency measurement100 ppm; depending on measuring interval and signal evaluation
Integrated Functions > Measuring functions > Accuracy > Cycle duration measurement100 ppm; depending on measuring interval and signal evaluation
Integrated Functions > Measuring functions > Accuracy > Velocity measurement100 ppm; depending on measuring interval and signal evaluation
Potential separation > Potential separation channels > between the channels and backplane busYes
Isolation > Isolation tested with750 V DC (type test) and according to EN 50155 (routine test)
Standards, approvals, certificates > Suitable for safety functionsNo
Standards, approvals, certificates > Railway application > EN 50121-3-2Yes; EMC for rail vehicles
Standards, approvals, certificates > Railway application > EN 50121-4Yes; EMC for signal and telecommunications systems
Standards, approvals, certificates > Railway application > EN 50121-5Yes; EMC for fixed installations and railway power supply equipment (shielded cables required)
Standards, approvals, certificates > Railway application > EN 50124-1Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC
Standards, approvals, certificates > Railway application > EN 50125-1Yes; Rail vehicles - see ambient conditions
Standards, approvals, certificates > Railway application > EN 50125-2Yes; Stationary electrical equipment - see ambient conditions
Standards, approvals, certificates > Railway application > EN 50125-3Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)
Standards, approvals, certificates > Railway application > EN 50155Yes; Rail vehicles - temperature class OT2, ST1/ST2, horizontal mounting position
Standards, approvals, certificates > Railway application > EN 61373Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B
Standards, approvals, certificates > Railway application > Fire protection acc. to EN 45545-2Yes; For proof of conformity, see Service & Support
Ambient conditions > Ambient temperature during operation > horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
Ambient conditions > Ambient temperature during operation > horizontal installation, max.60 °C; = Tmax; +70 °C for 10 min (OT2, ST1/ST2 acc. to EN 50155); +70 °C continuously with configured slots to the left and right of the module (OT4, ST1/ST2 acc. to EN 50155)
Ambient conditions > Ambient temperature during operation > vertical installation, min.-40 °C; = Tmin
Ambient conditions > Ambient temperature during operation > vertical installation, max.50 °C; = Tmax; see Derating BasedOn (e.g. manual)
Ambient conditions > Ambient temperature during operation > ceiling installation, min.-40 °C; = Tmin
Ambient conditions > Ambient temperature during operation > ceiling installation, max.50 °C; = Tmax
Ambient conditions > Ambient temperature during operation > floor installation, min.-40 °C; = Tmin
Ambient conditions > Ambient temperature during operation > floor installation, max.50 °C; = Tmax
Ambient conditions > Altitude during operation relating to sea level > Installation altitude above sea level, max.2 000 m
Ambient conditions > Altitude during operation relating to sea level > Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Ambient conditions > Relative humidity > With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Ambient conditions > Resistance > Coolants and lubricants > Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Ambient conditions > Resistance > Use in stationary industrial systems > to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
Ambient conditions > Resistance > Use in stationary industrial systems > to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Ambient conditions > Resistance > Use in stationary industrial systems > to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Ambient conditions > Resistance > Use in stationary industrial systems > Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0//6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to biologically active substances according to EN 60721-3-5Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to chemically active substances according to EN 60721-3-5Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > to mechanically active substances according to EN 60721-3-5Yes; Class 5S3 incl. sand, dust; *
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > Against mechanical environmental conditions acc. to EN 60721-3-5Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Use on land craft, rail vehicles and special-purpose vehicles > against mechanical environmental conditions in agriculture acc. to ISO 15003Yes; Level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0)
Ambient conditions > Resistance > Usage in industrial process technology > Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Ambient conditions > Resistance > Usage in industrial process technology > Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Ambient conditions > Resistance > Remark > Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Ambient conditions > Conformal coating > Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Ambient conditions > Conformal coating > Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Ambient conditions > Conformal coating > Electronic equipment on rolling stock acc. to EN 50155Yes; class PC2 protective coating acc. to EN 50155
Ambient conditions > Conformal coating > Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Ambient conditions > Conformal coating > Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Decentralized operation > to SIMATIC S7-300Yes
Decentralized operation > to SIMATIC S7-400Yes
Decentralized operation > to SIMATIC S7-1200Yes
Decentralized operation > to SIMATIC S7-1500Yes
Decentralized operation > to standard PROFIBUS masterYes
Decentralized operation > to standard PROFINET controllerYes
Dimensions > Width15 mm
Dimensions > Height73 mm
Dimensions > Depth58 mm
Weights > Weight, approx.45 g
Other > Note:for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp