Industrial Automation Parts. Prompt replies from real people.

ABB AF265-30-22-42 3-Pole Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB AF265-30-22-42?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AF265-30-22-42 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AF265-30-22-42
Material Number
1SFL547002R4222
Manufacturer
ABB
Product ID
87731

Get a Free Quote

Request pricing and availability for AF265-30-22-42.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
3.9 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 350 A (1000 V) 60 °C 300 A (1000 V) 70 °C 240 A (690 V) 40 °C 400 A (690 V) 60 °C 350 A (690 V) 70 °C 290 A
Rated Operational Power AC-3 (Pe)
(415 V) 132 kW (440 V) 160 kW (500 V) 160 kW (690 V) 200 kW (1000 V) 160 kW (380 / 400 V) 132 kW (220 / 230 / 240 V) 75 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
See all specifications

Product Highlights

  1. Coil and Contacts: 110 to 120 V AC control coil at 50/60 Hz, three normally open main contacts, and two normally open plus two normally closed auxiliary contacts
  2. Switching Ratings: AC-3 rated operational current of 265 A at 380 to 440 V and 250 A at 500 to 690 V, with AC-3 rated operational power up to 200 kW at 690 V
  3. Current Capability: Conventional free-air thermal current of 400 A and AC-1 rated operational current of 350 A at 1000 V and 40 °C, derating to 240 A at 70 °C
  4. Durability and Switching Frequency: 5 million mechanical operations and maximum switching frequency of 300 cycles per hour in AC-1 and AC-3
  5. Coil and Response: pull-in consumption of 340 V·A, holding consumption of 17 V·A and 3 W, and operate time of 20 to 35 ms for NO contact closing and 20 to 30 ms for NO contact opening
  6. Terminations and Protection: main circuit bar terminals with IP00 protection, auxiliary and control circuit terminals with IP20 protection, and auxiliary/control wire stripping length of 9 mm
  7. Operating Conditions: ambient air temperature range of -40 to 70 °C without thermal overload relay and maximum operating altitude of 3000 m without derating
AF265-30-22-42

Product Information

Technical Specifications

Specifications for AF265-30-22-42

ParameterValue
Product Net Width160 mm
Product Net Depth / Length180 mm
Product Net Height225 mm
Product Net Weight3.9 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 350 A (1000 V) 60 °C 300 A (1000 V) 70 °C 240 A (690 V) 40 °C 400 A (690 V) 60 °C 350 A (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 265 A (440 V) 60 °C 265 A (500 V) 60 °C 250 A (690 V) 60 °C 250 A (1000 V) 60 °C 113 A (380400 V) 60 °C 265 A (220230240 V) 60 °C 265 A
Rated Operational Power AC-3 (Pe)(415 V) 132 kW (440 V) 160 kW (500 V) 160 kW (690 V) 200 kW (1000 V) 160 kW (380400 V) 132 kW (220230240 V) 75 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3300 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
ParameterValue
Rated Control Circuit Voltage (Uc)50 Hz 110 ... 120 V 60 Hz 110 ... 120 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 17 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W Holding at Max. Rated Control Circuit Voltage 60 Hz 17 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 340 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 340 V·A
Operate TimeBetween Coil De-energization and NO Contact Opening 20 ... 30 ms Between Coil Energization and NO Contact Closing 20 ... 35 ms
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 1x 0.75 ... 2.5 mm² Flexible 2x 0.75 ... 2.5 mm² Solid 1x 1 ... 4 mm² Solid 2x 1 ... 4 mm² Stranded 1x 1 ... 4 mm² Stranded 2x 1 ... 4 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm Control Circuit 9 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars
NEMA Size5
Continuous Current Rating NEMA270 A
Horsepower Rating NEMA(200 V AC) Three Phase 75 Hp (230 V AC) Three Phase 100 Hp (460 V AC) Three Phase 200 Hp (575 V AC) Three Phase 200 Hp
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(600 V AC) 350 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 75 hp (220 ... 240 V AC) Three Phase 100 hp (440 ... 480 V AC) Three Phase 200 hp (550 ... 600 V AC) Three Phase 250 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb Control Circuit 9 in·lb Main Circuit 372 in·lb
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
Manufacturer ID1SFL547002R4222

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
ABB AF265-30-22-42 3-Pole Contactor for Motor Control and Power Switching