- AF265-40-00-11
The ABB AF265-40-00-11 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 at 40 °C. AC-1 ratings include 350 A at 1000 V and 40 °C, and 400 A at 690 V and 40 °C. AC-3 ratings include 265 A at 415 V and 55 °C, with rated operational power of 132 kW at 415 V. Short-circuit protection is provided by gG type fuses rated 630 A. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.
- AF265-40-00-12
The ABB AF265-40-00-12 is a non-reversing AC contactor with four normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V at 60 Hz, with a conventional free-air thermal current of 400 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, and 250 A at 500 V and 690 V, all at 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, and 160 kW at 440 V. The control circuit voltage range is 48 to 130 V at 50 Hz, 60 Hz, and DC. Mechanical durability is 5 million operating cycles. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high, weighing 5.7 kg.
- AF265-40-00-14
The ABB AF265-40-00-14 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a main circuit frequency of 60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 350 A at 1000 V and 40 °C, 300 A at 1000 V and 60 °C, and 400 A at 690 V and 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high, with a net weight of 5.7 kg.
- AF265-40-11-11
The ABB AF265-40-11-11 is a 4-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V and at 380/400 V. Main circuit terminals are bars; dimensions are 184.4 mm wide, 180 mm deep, and 225 mm high, with a net weight of 5.7 kg.
- AF265-40-11-12
The ABB AF265-40-11-12 is a 4-pole AC contactor with four main contacts NO and no main contacts NC, plus one auxiliary contact NO and one auxiliary contact NC. Main circuit rated operational voltage is 1000 V at 60 Hz. Rated operational current AC-3 is 265 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 55 °C, and 250 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 is 132 kW at 380/400 V and 415 V, 160 kW at 440 V, and 75 kW at 220/230/240 V. Coil control voltage range is 48 to 130 V at 50 Hz, 60 Hz, and DC. Dimensions are 184.4 mm wide, 180 mm deep, and 225 mm high, weighing 5.7 kg.
- AF265-40-11-13
ABB AF265-40-11-13 AC contactor, manufacturer ID 1SFL547102R1311. Four main contacts NO and no main contacts NC, with one auxiliary contact NO and one auxiliary contact NC. Main circuit rated operational voltage 1000 V at 50 Hz. Conventional free-air thermal current per IEC 60947-4-1 is 400 A at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V. Control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 184.4 mm wide, 180 mm deep, and 225 mm high; net weight 5.7 kg. Mechanical durability is 5 million operating cycles.
- AF265-40-11-14
ABB AF265-40-11-14 is a 4-pole AC contactor with 4 NO main contacts and no NC main contacts, plus 1 NO and 1 NC auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V and at 380/400 V. Coil voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. Dimensions are 225 mm H x 184.4 mm W x 180 mm D; net weight 5.7 kg. Main terminals are bars; main terminals IP00, coil terminals IP20.
- AF265-40-22-11
The ABB AF265-40-22-11 is a 4-pole AC contactor with four normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a main circuit frequency of 60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 55 °C, and 250 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 is 132 kW at 380/400 V and 415 V, 160 kW at 440 V, and 75 kW at 220/230/240 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.