- AF265-40-22-11
The ABB AF265-40-22-11 is a 4-pole AC contactor with four normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a main circuit frequency of 60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 55 °C, and 250 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 is 132 kW at 380/400 V and 415 V, 160 kW at 440 V, and 75 kW at 220/230/240 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.
- AF265-40-22-12
The ABB AF265-40-22-12 is a four-pole AC contactor with four normally open main contacts and no normally closed main contacts, plus two normally open and two normally closed auxiliary contacts. Main circuit rated operational voltage is 1000 V at 60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V and at 380/400 V. Coil control voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.
- AF265-40-22-14
The ABB AF265-40-22-14 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It includes two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high, with a net weight of 5.7 kg. Short-circuit protection uses gG type fuses rated 630 A.
- AF265-G
ABB AF265-G contactor. Manufacturer ID: 2TCZ102015R2240. The supplied data lists no electrical ratings, standards, certifications, or application information. Dimensions are 86 mm net width, 40 mm net height, and 86 mm net depth or length, with a net weight of 165 g. No other performance, compatibility, or compliance details are provided.
- AF2650-30-00-70
The ABB AF2650-30-00-70 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V, and the rated operational current AC-1 (Ie) is 2650 A at 40 °C, 2350 A at 55 °C, and 2120 A at 70 °C, at both 690 V and 1000 V. Rated insulation voltage (Ui) is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 1000 V according to UL/CSA. Rated control circuit voltage (Uc) is 100 Hz 100 to 250 V. Main circuit terminals are bars. Net dimensions are 438 mm wide, 244 mm deep, and 422 mm high; net weight is 43 kg. Manufacturer ID: 1SFL667001R7000.
- AF2650-30-11-70
The ABB AF2650-30-11-70 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 2650 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 2650 A at 1000 V and 40 °C, derating to 2350 A at 55 °C and 2120 A at 70 °C. The control circuit voltage range is 100 to 250 V AC/DC. Mechanical durability is 0.3 million operations, with a maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 438 mm wide, 244 mm deep, and 422 mm high; net weight is 43 kg.
- AF2650-30-11-70 CT19001
The ABB AF2650-30-11-70 CT19001 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 1140 V in the main circuit at 50/60 Hz, with a conventional free-air thermal current of 2650 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 2650 A at 1000 V and 40 °C, 2350 A at 55 °C, and 2120 A at 70 °C. Rated insulation voltage is 1140 V to IEC 60947-4-1 and VDE 0110 Group C, and 1000 V to UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 0.3 million operations, with maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 438 mm wide, 244 mm deep, and 422 mm high; net weight is 43 kg.
- AF2650-30-22-70
The ABB AF2650-30-22-70 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with a conventional free-air thermal current of 2650 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 2650 A at 40 °C and 2350 A at 55 °C at both 690 V and 1000 V. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 8 kV, and mechanical durability is 0.3 million operations. Dimensions are 438 mm wide, 244 mm deep, and 422 mm high; weight is 43 kg.