- AF2650-30-00-70
The ABB AF2650-30-00-70 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V, and the rated operational current AC-1 (Ie) is 2650 A at 40 °C, 2350 A at 55 °C, and 2120 A at 70 °C, at both 690 V and 1000 V. Rated insulation voltage (Ui) is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 1000 V according to UL/CSA. Rated control circuit voltage (Uc) is 100 Hz 100 to 250 V. Main circuit terminals are bars. Net dimensions are 438 mm wide, 244 mm deep, and 422 mm high; net weight is 43 kg. Manufacturer ID: 1SFL667001R7000.
- AF2650-30-11-70
The ABB AF2650-30-11-70 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 2650 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 2650 A at 1000 V and 40 °C, derating to 2350 A at 55 °C and 2120 A at 70 °C. The control circuit voltage range is 100 to 250 V AC/DC. Mechanical durability is 0.3 million operations, with a maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 438 mm wide, 244 mm deep, and 422 mm high; net weight is 43 kg.
- AF2650-30-11-70 CT19001
The ABB AF2650-30-11-70 CT19001 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 1140 V in the main circuit at 50/60 Hz, with a conventional free-air thermal current of 2650 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 2650 A at 1000 V and 40 °C, 2350 A at 55 °C, and 2120 A at 70 °C. Rated insulation voltage is 1140 V to IEC 60947-4-1 and VDE 0110 Group C, and 1000 V to UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 0.3 million operations, with maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 438 mm wide, 244 mm deep, and 422 mm high; net weight is 43 kg.
- AF2650-30-22-70
The ABB AF2650-30-22-70 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with a conventional free-air thermal current of 2650 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 2650 A at 40 °C and 2350 A at 55 °C at both 690 V and 1000 V. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 8 kV, and mechanical durability is 0.3 million operations. Dimensions are 438 mm wide, 244 mm deep, and 422 mm high; weight is 43 kg.
- AF2650-30-22-70 CT19001
ABB AF2650-30-22-70 CT19001 is a 3-pole AC contactor, manufacturer ID 1SFL667033R7022. It has 3 NO main contacts, 2 NO and 2 NC auxiliary contacts. The main circuit is rated 1140 V at 50/60 Hz, with conventional free-air thermal current 2650 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 2650 A at 1000 V, 690 V, and 1140 V at 40 °C, 2350 A at 55 °C, and 2120 A at 70 °C. Rated insulation voltage is 1140 V per IEC 60947-4-1 and VDE 0110 Gr. C, 1000 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Dimensions are 438 mm wide, 244 mm deep, and 422 mm high; net weight 43 kg.
- AF2650B-30-22-70
The ABB AF2650B-30-22-70 is a 3-pole AC contactor, manufacturer ID 1SFL667063R7022, classified under ETIM EC000066 as a power contactor for AC switching. It measures 438 mm wide, 244 mm deep, and 422 mm high, with a net weight of 43 kg. Coil consumption is 2450 V·A pull-in and 48 V·A holding at the maximum rated control circuit voltage at 50 Hz. Ambient air temperature limits are -25 to 50 °C close to the contactor fitted with a thermal overload relay at 0.85 to 1.1 Uc, and -40 to 70 °C without a thermal overload relay at 0.85 to 1.1 Uc.
- AF2650T-30-11 230-240V 50/60Hz
ABB AF2650T-30-11 230-240V 50/60Hz is a three-pole AC contactor with three normally open main contacts, two normally open auxiliary contacts, and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 2650 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 2650 A at 1000 V and 40 °C, 2350 A at 55 °C, and 2120 A at 70 °C. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and per UL/CSA. Rated impulse withstand voltage for the main circuit is 8 kV. Mechanical durability is 0.3 million operations. Net weight is 43 kg.
- AF265B-30-22-11
The ABB AF265B-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V. Rated operational current AC-1 is 400 A at 690 V and 40 °C, 350 A at 690 V and 60 °C, and 290 A at 690 V and 70 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 132 kW at 380/400 V. Control circuit voltage is 24 to 60 V at 50/60 Hz and 20 to 60 V DC. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.