- AF265B-30-22-12
ABB AF265B-30-22-12 AC contactor, manufacturer ID 1SFL547063R1222. Three main poles, 3 NO main contacts and 0 NC main contacts, with 2 NO and 2 NC auxiliary contacts. Main circuit rated operational voltage 1000 V. Rated operational current AC-3 (Ie): 265 A at 415 V and 55 °C, 250 A at 690 V and 55 °C, 100 A at 1000 V and 55 °C. Rated operational power AC-3 (Pe): 132 kW at 415 V, 200 kW at 690 V, 160 kW at 1000 V. Rated control circuit voltage (Uc): 48 to 130 V DC operation. Main circuit terminals are bars. Dimensions 140 mm width, 180 mm depth, 225 mm height; net weight 3.9 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF265B-30-22-13
The ABB AF265B-30-22-13 is a 3-pole AC contactor with 3 NO main contacts and 2 NO plus 2 NC auxiliary contacts. Main circuit rated operational voltage is 1000 V. Rated operational current AC-3 is 265 A at 415 V and 55 °C, 250 A at 500 V and 55 °C, and 100 A at 1000 V and 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, 160 kW at 440 V and 1000 V, and 200 kW at 500 V and 690 V. Control circuit voltage is 100 to 250 V DC. Dimensions are 140 mm width, 180 mm depth, 225 mm height; net weight 3.9 kg. Mechanical durability is 5 million operations. Standards include IEC/EN 60947-4-1 and UL 60947-4-1.
- AF265B-30-22-14
ABB AF265B-30-22-14 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, weighing 3.9 kg. Rated operational voltage for the main circuit is 1000 V. Rated operational current AC-3 is 265 A at 380/400 V and 55 °C, with rated operational power AC-3 of 132 kW at 380/400 V. Mechanical durability is 5 million operations, with a maximum mechanical switching frequency of 300 cycles per hour. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF265B-30-22RT-11
The ABB AF265B-30-22RT-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The rated operational voltage of the main circuit is 1000 V. Rated operational current AC-3 is 265 A at 415 V and 440 V, 250 A at 500 V and 690 V, and 100 A at 1000 V, all at 55 °C. Rated control circuit voltage is 24 to 60 V AC/DC. Mechanical durability is 5 million operations, with a maximum mechanical switching frequency of 300 cycles per hour. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF265B-30-22RT-12
ABB AF265B-30-22RT-12 is a 3-pole AC contactor, manufacturer ID 1SFL547062R1222. It has 3 main contacts NO, 0 main contacts NC, and 2 auxiliary contacts NO plus 2 auxiliary contacts NC. Rated operational voltage for the main circuit is 1000 V. Rated operational current AC-3 is 265 A at 380/400 V and 55 °C, and rated operational power AC-3 is 132 kW at 380/400 V. The rated control circuit voltage is 48 to 130 V at 50/60 Hz and 48 to 130 V DC. Mechanical durability is 5 million cycles, with a maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 3.9 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF265B-30-22RT-13
The ABB AF265B-30-22RT-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. Rated operational voltage for the main circuit is 1000 V. Rated operational current AC-3 is 265 A at 380/400 V and 55 °C, and rated operational power AC-3 is 132 kW at 380/400 V. Control circuit voltage is 100 to 250 V AC at 50/60 Hz or 100 to 250 V DC. Mechanical durability is 5 million cycles, with a maximum mechanical switching frequency of 300 cycles per hour. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF265B-30-22RT-14
The ABB AF265B-30-22RT-14 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V, with AC-3 ratings of 265 A at 380/400 V and 55 °C, and AC-3 power ratings of 132 kW at 380/400 V and 415 V, 160 kW at 440 V, and 200 kW at 500 V and 690 V. The control circuit voltage is 250 to 500 V at 50/60 Hz and 250 to 500 V DC. Mechanical durability is 5 million operations, with a maximum mechanical switching frequency of 300 cycles per hour. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF265B-40-22-11
ABB AF265B-40-22-11 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts, plus two normally open and two normally closed auxiliary contacts. It measures 184 mm wide, 180 mm deep, and 225 mm high, and weighs 5.7 kg. The main circuit is rated 1000 V. Rated operational current AC-3 is 265 A at 380/400 V and 415 V at 55 °C, and rated operational power AC-3 is 132 kW at 380/400 V and 415 V. Rated control circuit voltage is 24 to 60 V at 50/60 Hz and 20 to 60 V DC. Mechanical durability is 5 million operations, with a maximum mechanical switching frequency of 300 cycles per hour.