Product Model
AF265B-30-22-13
Material Number
1SFL547063R1322
Manufacturer
ABB
Product ID
70571

Get a Free Quote

Request pricing and availability for AF265B-30-22-13.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
3.9 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 350 A (1000 V) 60 °C 300 A (1000 V) 70 °C 240 A (690 V) 40 °C 400 A (690 V) 60 °C 350 A (690 V) 70 °C 290 A
Rated Operational Power AC-3 (Pe)
(415 V) 132 kW (440 V) 160 kW (500 V) 200 kW (690 V) 200 kW (1000 V) 160 kW (380 / 400 V) 132 kW (220 / 230 / 240 V) 75 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Maximum Mechanical Switching Frequency
300 cycles per hour
See all specifications

Product Highlights

  1. Contact Configuration: 3 main contacts normally open and no main contacts normally closed, plus 2 auxiliary contacts normally open and 2 auxiliary contacts normally closed
  2. Power Ratings: AC-3 rated operational power of 132 kW at 415 V and 380/400 V, 160 kW at 440 V and 1000 V, 200 kW at 500 V and 690 V, and 75 kW at 220/230/240 V
  3. Current Ratings: AC-1 rated operational current of 400 A at 690 V and 350 A at 1000 V at 40 °C, and AC-3 rated operational current of 265 A at 415 V, 440 V, and 380/400 V at 55 °C
  4. Coil and Control: Rated control circuit voltage of 100 to 250 V DC, with pull-in consumption of 385 V·A at 50/60 Hz and 410 W DC, and holding consumption of 17.5 V·A at 50/60 Hz
  5. Durability and Switching: Mechanical durability of 5 million operations and maximum mechanical switching frequency of 300 cycles per hour
  6. Terminals and Standards: Main circuit bar terminals, NEMA size 5, and compliance with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, EN 50155, TR CU 001/2011, and IEC 61373
AF265B-30-22-13

Product Information

Technical Specifications

Specifications for AF265B-30-22-13

ParameterValue
Product Net Width140 mm
Product Net Depth / Length180 mm
Product Net Height225 mm
Product Net Weight3.9 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational VoltageMain Circuit 1000 V
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 350 A (1000 V) 60 °C 300 A (1000 V) 70 °C 240 A (690 V) 40 °C 400 A (690 V) 60 °C 350 A (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 265 A (440 V) 55 °C 265 A (500 V) 55 °C 250 A (690 V) 55 °C 250 A (1000 V) 55 °C 100 A (380400 V) 55 °C 265 A (220230240 V) 55 °C 265 A
Rated Operational Power AC-3 (Pe)(415 V) 132 kW (440 V) 160 kW (500 V) 200 kW (690 V) 200 kW (1000 V) 160 kW (380400 V) 132 kW (220230240 V) 75 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Rated Operational Current DC-1 (Ie)(100 V) 1 Pole, 40 °C 400 A (100 V) 1 Pole, 60 °C 350 A (100 V) 1 Pole, 70 °C 290 A (110 V) 1-Pole, 40 °C 400 A (110 V) 1-Pole, 60 °C 350 A (110 V) 1-Pole, 70 °C 290 A (110 V) 2 Poles in Series, 40 °C 400 A (110 V) 2 Poles in Series, 60 °C 350 A (110 V) 2 Poles in Series, 70 °C 290 A (110 V) 3 Poles in Series, 40 °C 400 A (110 V) 3 Poles in Series, 60 °C 350 A (110 V) 3 Poles in Series, 70 °C 290 A (175 V) 2 Poles in Series, 40 °C 400 A (175 V) 2 Poles in Series, 60 °C 350 A (175 V) 2 Poles in Series, 70 °C 290 A (200 V) 2 Poles in Series, 40 °C 400 A (200 V) 2 Poles in Series, 60 °C 350 A (200 V) 2 Poles in Series, 70 °C 290 A (220 V) 2 Poles in Series, 40 °C 400 A (220 V) 2 Poles in Series, 60 °C 350 A (220 V) 2 Poles in Series, 70 °C 290 A (220 V) 3 Poles in Series, 40 °C 400 A (220 V) 3 Poles in Series, 60 °C 350 A (220 V) 3 Poles in Series, 70 °C 290 A (260 V) 3 Poles in Series, 40 °C 400 A (260 V) 3 Poles in Series, 60 °C 350 A (260 V) 3 Poles in Series, 70 °C 290 A (300 V) 3 Poles in Series, 40 °C 400 A (300 V) 3 Poles in Series, 60 °C 350 A (300 V) 3 Poles in Series, 70 °C 290 A (340 V) 3 Poles in Series, 40 °C 400 A (340 V) 3 Poles in Series, 60 °C 350 A (340 V) 3 Poles in Series, 70 °C 290 A (72 V) 1-Pole, 40 °C 400 A (72 V) 1-Pole, 60 °C 350 A (72 V) 1-Pole, 70 °C 290 A (72 V) 2 Poles in Series, 40 °C 400 A (72 V) 2 Poles in Series, 60 °C 350 A (72 V) 2 Poles in Series, 70 °C 290 A (72 V) 3 Poles in Series, 40 °C 400 A (72 V) 3 Poles in Series, 60 °C 350 A (72 V) 3 Poles in Series, 70 °C 290 A (90 V) 1 Pole, 40 °C 400 A (90 V) 1 Pole, 60 °C 350 A (90 V) 1 Pole, 70 °C 290 A
ParameterValue
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 350 A (110 V) 2 Poles in Series, 60 °C 350 A (110 V) 2 Poles in Series, 70 °C 290 A (110 V) 3 Poles in Series, 40 °C 350 A (110 V) 3 Poles in Series, 60 °C 350 A (110 V) 3 Poles in Series, 70 °C 290 A (220 V) 3 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 60 °C 350 A (220 V) 3 Poles in Series, 70 °C 290 A (72 V) 2 Poles in Series, 40 °C 350 A (72 V) 2 Poles in Series, 60 °C 350 A (72 V) 2 Poles in Series, 70 °C 290 A (72 V) 3 Poles in Series, 40 °C 350 A (72 V) 3 Poles in Series, 60 °C 350 A (72 V) 3 Poles in Series, 70 °C 290 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 350 A (110 V) 2 Poles in Series, 60 °C 350 A (110 V) 2 Poles in Series, 70 °C 290 A (110 V) 3 Poles in Series, 40 °C 350 A (110 V) 3 Poles in Series, 60 °C 350 A (110 V) 3 Poles in Series, 70 °C 290 A (220 V) 3 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 60 °C 350 A (220 V) 3 Poles in Series, 70 °C 290 A (72 V) 2 Poles in Series, 40 °C 350 A (72 V) 2 Poles in Series, 60 °C 350 A (72 V) 2 Poles in Series, 70 °C 290 A (72 V) 3 Poles in Series, 40 °C 350 A (72 V) 3 Poles in Series, 60 °C 350 A (72 V) 3 Poles in Series, 70 °C 290 A
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz / 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A Pull-in at Max. Rated Control Circuit Voltage DC 410 W
Terminal TypeMain Circuit: Bars
NEMA Size5
Continuous Current Rating NEMA270 A
Horsepower Rating NEMA(200 V AC) Three Phase 75 Hp (230 V AC) Three Phase 100 Hp (460 V AC) Three Phase 200 Hp (575 V AC) Three Phase 200 Hp
General Use Rating UL/CSA(600 V AC) 350 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 75 hp (220 ... 240 V AC) Three Phase 100 hp (440 ... 480 V AC) Three Phase 200 hp (550 ... 600 V AC) Three Phase 250 hp
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
E-Number (Sweden)3210450
Manufacturer ID1SFL547063R1322

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.