- AF2650-30-22-70 CT19001
ABB AF2650-30-22-70 CT19001 is a 3-pole AC contactor, manufacturer ID 1SFL667033R7022. It has 3 NO main contacts, 2 NO and 2 NC auxiliary contacts. The main circuit is rated 1140 V at 50/60 Hz, with conventional free-air thermal current 2650 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 2650 A at 1000 V, 690 V, and 1140 V at 40 °C, 2350 A at 55 °C, and 2120 A at 70 °C. Rated insulation voltage is 1140 V per IEC 60947-4-1 and VDE 0110 Gr. C, 1000 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Dimensions are 438 mm wide, 244 mm deep, and 422 mm high; net weight 43 kg.
- AF2650B-30-22-70
The ABB AF2650B-30-22-70 is a 3-pole AC contactor, manufacturer ID 1SFL667063R7022, classified under ETIM EC000066 as a power contactor for AC switching. It measures 438 mm wide, 244 mm deep, and 422 mm high, with a net weight of 43 kg. Coil consumption is 2450 V·A pull-in and 48 V·A holding at the maximum rated control circuit voltage at 50 Hz. Ambient air temperature limits are -25 to 50 °C close to the contactor fitted with a thermal overload relay at 0.85 to 1.1 Uc, and -40 to 70 °C without a thermal overload relay at 0.85 to 1.1 Uc.
- AF2650T-30-11 230-240V 50/60Hz
ABB AF2650T-30-11 230-240V 50/60Hz is a three-pole AC contactor with three normally open main contacts, two normally open auxiliary contacts, and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 2650 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 2650 A at 1000 V and 40 °C, 2350 A at 55 °C, and 2120 A at 70 °C. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and per UL/CSA. Rated impulse withstand voltage for the main circuit is 8 kV. Mechanical durability is 0.3 million operations. Net weight is 43 kg.
- AF265B-30-22-11
The ABB AF265B-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V. Rated operational current AC-1 is 400 A at 690 V and 40 °C, 350 A at 690 V and 60 °C, and 290 A at 690 V and 70 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 132 kW at 380/400 V. Control circuit voltage is 24 to 60 V at 50/60 Hz and 20 to 60 V DC. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF265B-30-22-12
ABB AF265B-30-22-12 AC contactor, manufacturer ID 1SFL547063R1222. Three main poles, 3 NO main contacts and 0 NC main contacts, with 2 NO and 2 NC auxiliary contacts. Main circuit rated operational voltage 1000 V. Rated operational current AC-3 (Ie): 265 A at 415 V and 55 °C, 250 A at 690 V and 55 °C, 100 A at 1000 V and 55 °C. Rated operational power AC-3 (Pe): 132 kW at 415 V, 200 kW at 690 V, 160 kW at 1000 V. Rated control circuit voltage (Uc): 48 to 130 V DC operation. Main circuit terminals are bars. Dimensions 140 mm width, 180 mm depth, 225 mm height; net weight 3.9 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF265B-30-22-13
The ABB AF265B-30-22-13 is a 3-pole AC contactor with 3 NO main contacts and 2 NO plus 2 NC auxiliary contacts. Main circuit rated operational voltage is 1000 V. Rated operational current AC-3 is 265 A at 415 V and 55 °C, 250 A at 500 V and 55 °C, and 100 A at 1000 V and 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, 160 kW at 440 V and 1000 V, and 200 kW at 500 V and 690 V. Control circuit voltage is 100 to 250 V DC. Dimensions are 140 mm width, 180 mm depth, 225 mm height; net weight 3.9 kg. Mechanical durability is 5 million operations. Standards include IEC/EN 60947-4-1 and UL 60947-4-1.
- AF265B-30-22-14
ABB AF265B-30-22-14 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, weighing 3.9 kg. Rated operational voltage for the main circuit is 1000 V. Rated operational current AC-3 is 265 A at 380/400 V and 55 °C, with rated operational power AC-3 of 132 kW at 380/400 V. Mechanical durability is 5 million operations, with a maximum mechanical switching frequency of 300 cycles per hour. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF265B-30-22RT-11
The ABB AF265B-30-22RT-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The rated operational voltage of the main circuit is 1000 V. Rated operational current AC-3 is 265 A at 415 V and 440 V, 250 A at 500 V and 690 V, and 100 A at 1000 V, all at 55 °C. Rated control circuit voltage is 24 to 60 V AC/DC. Mechanical durability is 5 million operations, with a maximum mechanical switching frequency of 300 cycles per hour. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.