- AF265-40-00-12
The ABB AF265-40-00-12 is a non-reversing AC contactor with four normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V at 60 Hz, with a conventional free-air thermal current of 400 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, and 250 A at 500 V and 690 V, all at 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, and 160 kW at 440 V. The control circuit voltage range is 48 to 130 V at 50 Hz, 60 Hz, and DC. Mechanical durability is 5 million operating cycles. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high, weighing 5.7 kg.
- AF265-40-00-14
The ABB AF265-40-00-14 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a main circuit frequency of 60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 350 A at 1000 V and 40 °C, 300 A at 1000 V and 60 °C, and 400 A at 690 V and 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high, with a net weight of 5.7 kg.
- AF265-40-11-11
The ABB AF265-40-11-11 is a 4-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V and at 380/400 V. Main circuit terminals are bars; dimensions are 184.4 mm wide, 180 mm deep, and 225 mm high, with a net weight of 5.7 kg.
- AF265-40-11-12
The ABB AF265-40-11-12 is a 4-pole AC contactor with four main contacts NO and no main contacts NC, plus one auxiliary contact NO and one auxiliary contact NC. Main circuit rated operational voltage is 1000 V at 60 Hz. Rated operational current AC-3 is 265 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 55 °C, and 250 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 is 132 kW at 380/400 V and 415 V, 160 kW at 440 V, and 75 kW at 220/230/240 V. Coil control voltage range is 48 to 130 V at 50 Hz, 60 Hz, and DC. Dimensions are 184.4 mm wide, 180 mm deep, and 225 mm high, weighing 5.7 kg.
- AF265-40-11-13
ABB AF265-40-11-13 AC contactor, manufacturer ID 1SFL547102R1311. Four main contacts NO and no main contacts NC, with one auxiliary contact NO and one auxiliary contact NC. Main circuit rated operational voltage 1000 V at 50 Hz. Conventional free-air thermal current per IEC 60947-4-1 is 400 A at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V. Control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 184.4 mm wide, 180 mm deep, and 225 mm high; net weight 5.7 kg. Mechanical durability is 5 million operating cycles.
- AF265-40-11-14
ABB AF265-40-11-14 is a 4-pole AC contactor with 4 NO main contacts and no NC main contacts, plus 1 NO and 1 NC auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V and at 380/400 V. Coil voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. Dimensions are 225 mm H x 184.4 mm W x 180 mm D; net weight 5.7 kg. Main terminals are bars; main terminals IP00, coil terminals IP20.
- AF265-40-22-11
The ABB AF265-40-22-11 is a 4-pole AC contactor with four normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a main circuit frequency of 60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 55 °C, and 250 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 is 132 kW at 380/400 V and 415 V, 160 kW at 440 V, and 75 kW at 220/230/240 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.
- AF265-40-22-12
The ABB AF265-40-22-12 is a four-pole AC contactor with four normally open main contacts and no normally closed main contacts, plus two normally open and two normally closed auxiliary contacts. Main circuit rated operational voltage is 1000 V at 60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V and at 380/400 V. Coil control voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.