- AF40-40-00-14LU
The ABB AF40-40-00-14LU is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 113.5 mm deep, and 125.5 mm high, weighing 1.21 kg. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V to IEC 60947-4-1 and 600 V to UL/CSA. Rated operational current AC-3 is 40 A at 415 V, 440 V, and 380/400 V, and 25 A at 690 V, at 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF400-30-00-68
The ABB AF400-30-00-68 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V, with AC-1 ratings of 600 A at 40 °C, 500 A at 55 °C, and 400 A at 70 °C at both 690 V and 1000 V. AC-3 ratings include 400 A at 415, 440, 500, and 380/400 V at 55 °C, 350 A at 690 V, and 155 A at 1000 V. AC-3 power ratings include 200 kW at 380/400 V, 220 kW at 415, 440, and 1000 V, 250 kW at 500 V, and 315 kW at 690 V. The control circuit is rated 24 to 60 V at 50 Hz. Mechanical durability is 3 million cycles. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; weight is 10.6 kg.
- AF400-30-00-69
The ABB AF400-30-00-69 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V, with AC-1 rated operational current of 600 A at 40 °C and 400 A at 70 °C at 1000 V. AC-3 ratings include 400 A at 415 V and 155 A at 1000 V, both at 55 °C. Rated control circuit voltage is 48 to 130 V at 50 Hz. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg. Main circuit terminals are bars. Mechanical durability is 3 million operations. Manufacturer ID: 1SFL577001R6900.
- AF400-30-00-70
The ABB AF400-30-00-70 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It has a rated operational voltage of 1000 V for the main circuit. Rated operational current is 600 A at 40 °C and 400 A at 70 °C for AC-1, and 400 A at 55 °C for AC-3 at 415 V. Rated operational power for AC-3 is 220 kW at 415 V and 200 kW at 380/400 V. The control circuit voltage is 100 to 250 V at 50 Hz. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. Main circuit terminals are bars.
- AF400-30-00-71
The ABB AF400-30-00-71 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 1000 V. Rated operational current AC-1 is 600 A at 40 °C, 500 A at 55 °C, and 400 A at 70 °C at both 690 V and 1000 V. Rated operational current AC-3 is 400 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, 350 A at 690 V, and 155 A at 1000 V. Rated control circuit voltage is 250 to 500 V at 50 Hz. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg. Main circuit terminals are bars. Mechanical durability is 3 million operating cycles.
- AF400-30-11
The ABB AF400-30-11 is a three-pole AC contactor with three main contacts NO and no main or auxiliary contacts NC. The main circuit is rated 1000 V, with AC-1 ratings of 600 A at 40 °C, 500 A at 55 °C, and 400 A at 70 °C at both 690 V and 1000 V. AC-3 ratings include 400 A at 415 V, 440 V, 500 V, and 380/400 V, and 350 A at 690 V, all at 55 °C. AC-3 rated power includes 200 kW at 380/400 V and 315 kW at 690 V. The control circuit accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; weight is 10.6 kg. Mechanical durability is 3 million operations. Main circuit terminals are bars.
- AF400-30-11-68
The ABB AF400-30-11-68 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with conventional free-air thermal current of 600 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 400 A at 415 V and 55 °C, and rated operational power AC-3 is 220 kW at 415 V. The DC control circuit voltage range is 24 to 60 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. Main terminals are bars; main terminal protection is IP00 and coil terminals IP20 per IEC 60529.
- AF400-30-11-70
The ABB AF400-30-11-70 is a three-phase AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Rated operational current AC-3 is 400 A at 415 V, 440 V, 500 V, 380/400 V, and 220/230/240 V, all at 55 °C; 350 A at 690 V and 155 A at 1000 V at 55 °C. Rated operational power AC-3 includes 200 kW at 380/400 V, 220 kW at 415 V and 440 V, 250 kW at 500 V, and 315 kW at 690 V. The control circuit voltage is 100 to 250 V for 50 Hz, 60 Hz, and DC operation. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg.