- AF400-30-11-68
The ABB AF400-30-11-68 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with conventional free-air thermal current of 600 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 400 A at 415 V and 55 °C, and rated operational power AC-3 is 220 kW at 415 V. The DC control circuit voltage range is 24 to 60 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. Main terminals are bars; main terminal protection is IP00 and coil terminals IP20 per IEC 60529.
- AF400-30-11-70
The ABB AF400-30-11-70 is a three-phase AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Rated operational current AC-3 is 400 A at 415 V, 440 V, 500 V, 380/400 V, and 220/230/240 V, all at 55 °C; 350 A at 690 V and 155 A at 1000 V at 55 °C. Rated operational power AC-3 includes 200 kW at 380/400 V, 220 kW at 415 V and 440 V, 250 kW at 500 V, and 315 kW at 690 V. The control circuit voltage is 100 to 250 V for 50 Hz, 60 Hz, and DC operation. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg.
- AF400-30-11-71
ABB AF400-30-11-71 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with AC-3 rated operational current of 400 A at 415 V and 55 °C, and AC-3 rated operational power of 220 kW at 415 V. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 at 40 °C. The control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. Dimensions are 186 mm width, 216 mm depth, and 278 mm height, with a net weight of 10.6 kg. Main terminals are bars; coil terminals are IP20 and main terminals IP00 according to IEC 60529. Mechanical durability is 3 million operations.
- AF400-30-22 100-250V
The ABB AF400-30-22 100-250V is a three-pole AC contactor with three normally open main contacts and no normally closed main contacts. It includes two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V, with AC-1 ratings of 600 A at 40 °C and 400 A at 70 °C at 1000 V. AC-3 ratings include 400 A at 415 V and 155 A at 1000 V, both at 55 °C. AC-3 rated operational power includes 200 kW at 380/400 V and 315 kW at 690 V. The control circuit voltage range is 100 to 250 V AC/DC. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg.
- AF400-30-22-68
ABB AF400-30-22-68 is a three-phase non-reversing AC contactor with a 48-130 V AC/DC coil. It has three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 400 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, and 350 A at 690 V at 55 °C. Rated operational power AC-3 is 220 kW at 415 V and 440 V, 250 kW at 500 V, and 315 kW at 690 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg.
- AF400-30-22-69
The ABB AF400-30-22-69 is a three-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Rated operational current AC-3 is 400 A at 380/400 V, 415 V, 440 V and 500 V, and 350 A at 690 V, all at 55 °C. Rated operational power AC-3 is 200 kW at 380/400 V, 220 kW at 415 V, 440 V and 1000 V, 250 kW at 500 V, and 315 kW at 690 V. Conventional free-air thermal current Ith is 600 A per IEC 60947-4-1 for open contactors at 40 °C. Dimensions are 186 mm wide, 216 mm deep and 278 mm high; net weight is 10.6 kg.
- AF400-30-22-70
The ABB AF400-30-22-70 is a 3-pole AC contactor with three normally open main contacts and four auxiliary contacts (two NO, two NC). The main circuit is rated 1000 V at 50/60 Hz, with conventional free-air thermal current of 600 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 400 A at 415 V and 55 °C; rated operational power AC-3 is 200 kW at 380/400 V and 220 kW at 415 V. The control circuit accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg. Main terminals are bars; coil terminals are IP20 and main terminals IP00 according to IEC 60529.
- AF400-30-22-71
The ABB AF400-30-22-71 is a three-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 400 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, 350 A at 690 V, and 155 A at 1000 V. Rated operational power AC-3 includes 200 kW at 380/400 V, 220 kW at 415 V, 250 kW at 500 V, and 315 kW at 690 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; weight is 10.6 kg. Short-circuit protection uses gG type fuses rated 630 A.