- AF400-30-00-68
The ABB AF400-30-00-68 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V, with AC-1 ratings of 600 A at 40 °C, 500 A at 55 °C, and 400 A at 70 °C at both 690 V and 1000 V. AC-3 ratings include 400 A at 415, 440, 500, and 380/400 V at 55 °C, 350 A at 690 V, and 155 A at 1000 V. AC-3 power ratings include 200 kW at 380/400 V, 220 kW at 415, 440, and 1000 V, 250 kW at 500 V, and 315 kW at 690 V. The control circuit is rated 24 to 60 V at 50 Hz. Mechanical durability is 3 million cycles. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; weight is 10.6 kg.
- AF400-30-00-69
The ABB AF400-30-00-69 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V, with AC-1 rated operational current of 600 A at 40 °C and 400 A at 70 °C at 1000 V. AC-3 ratings include 400 A at 415 V and 155 A at 1000 V, both at 55 °C. Rated control circuit voltage is 48 to 130 V at 50 Hz. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg. Main circuit terminals are bars. Mechanical durability is 3 million operations. Manufacturer ID: 1SFL577001R6900.
- AF400-30-00-70
The ABB AF400-30-00-70 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It has a rated operational voltage of 1000 V for the main circuit. Rated operational current is 600 A at 40 °C and 400 A at 70 °C for AC-1, and 400 A at 55 °C for AC-3 at 415 V. Rated operational power for AC-3 is 220 kW at 415 V and 200 kW at 380/400 V. The control circuit voltage is 100 to 250 V at 50 Hz. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. Main circuit terminals are bars.
- AF400-30-00-71
The ABB AF400-30-00-71 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. Main circuit rated operational voltage is 1000 V. Rated operational current AC-1 is 600 A at 40 °C, 500 A at 55 °C, and 400 A at 70 °C at both 690 V and 1000 V. Rated operational current AC-3 is 400 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, 350 A at 690 V, and 155 A at 1000 V. Rated control circuit voltage is 250 to 500 V at 50 Hz. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg. Main circuit terminals are bars. Mechanical durability is 3 million operating cycles.
- AF400-30-11
The ABB AF400-30-11 is a three-pole AC contactor with three main contacts NO and no main or auxiliary contacts NC. The main circuit is rated 1000 V, with AC-1 ratings of 600 A at 40 °C, 500 A at 55 °C, and 400 A at 70 °C at both 690 V and 1000 V. AC-3 ratings include 400 A at 415 V, 440 V, 500 V, and 380/400 V, and 350 A at 690 V, all at 55 °C. AC-3 rated power includes 200 kW at 380/400 V and 315 kW at 690 V. The control circuit accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; weight is 10.6 kg. Mechanical durability is 3 million operations. Main circuit terminals are bars.
- AF400-30-11-68
The ABB AF400-30-11-68 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with conventional free-air thermal current of 600 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 400 A at 415 V and 55 °C, and rated operational power AC-3 is 220 kW at 415 V. The DC control circuit voltage range is 24 to 60 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. Main terminals are bars; main terminal protection is IP00 and coil terminals IP20 per IEC 60529.
- AF400-30-11-70
The ABB AF400-30-11-70 is a three-phase AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Rated operational current AC-3 is 400 A at 415 V, 440 V, 500 V, 380/400 V, and 220/230/240 V, all at 55 °C; 350 A at 690 V and 155 A at 1000 V at 55 °C. Rated operational power AC-3 includes 200 kW at 380/400 V, 220 kW at 415 V and 440 V, 250 kW at 500 V, and 315 kW at 690 V. The control circuit voltage is 100 to 250 V for 50 Hz, 60 Hz, and DC operation. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg.
- AF400-30-11-71
ABB AF400-30-11-71 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with AC-3 rated operational current of 400 A at 415 V and 55 °C, and AC-3 rated operational power of 220 kW at 415 V. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 at 40 °C. The control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. Dimensions are 186 mm width, 216 mm depth, and 278 mm height, with a net weight of 10.6 kg. Main terminals are bars; coil terminals are IP20 and main terminals IP00 according to IEC 60529. Mechanical durability is 3 million operations.