- AF265-30-22-31
The ABB AF265-30-22-31 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with AC-3 ratings of 265 A at 415 V and 132 kW at 415 V. Coil voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Mechanical durability is 5 million operations. Dimensions are 160 mm wide, 191 mm deep, and 225 mm high, weighing 3.9 kg. Main terminals are bars; main terminals are IP00 and coil terminals IP20. Maximum operating altitude without derating is 3000 m.
- AF265-30-22-32
ABB AF265-30-22-32 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, both at 60 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, and 160 kW at 440 V, 500 V, and 1000 V. Dimensions are 160 mm wide, 191 mm deep, and 225 mm high; net weight is 3.9 kg.
- AF265-30-22-33
The ABB AF265-30-22-33 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V at 55 °C, and 250 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, and 160 kW at 440 V, 500 V, and 1000 V. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high; net weight is 3.9 kg.
- AF265-30-22-34
The ABB AF265-30-22-34 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 265 A at 415 V and 55 °C, and AC-3 rated operational power is 132 kW at 415 V. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high, with a net weight of 3.9 kg. Short-circuit protection requires gG type fuses rated 500 A.
- AF265-30-22-42
The ABB AF265-30-22-42 is a 3-pole AC contactor with main circuit bars, identified by manufacturer ID 1SFL547002R4222. It has 3 normally open main contacts, 2 normally open auxiliary contacts, and 2 normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 400 A at 40 °C. Rated operational current AC-3 is 265 A at 380/400 V and 415 V at 60 °C, with rated operational power AC-3 of 132 kW at 380/400 V and 415 V. Dimensions are 160 mm wide, 180 mm deep, and 225 mm high; net weight is 3.9 kg.
- AF265-30-22-43
The ABB AF265-30-22-43 is a 3-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 160 mm wide, 180 mm deep, and 225 mm high, weighing 3.9 kg. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, 250 A at 500 V and 690 V, and 113 A at 1000 V, all at 60 °C. Rated operational power AC-3 includes 132 kW at 415 V and 200 kW at 690 V. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C).
- AF265-40-00-11
The ABB AF265-40-00-11 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 at 40 °C. AC-1 ratings include 350 A at 1000 V and 40 °C, and 400 A at 690 V and 40 °C. AC-3 ratings include 265 A at 415 V and 55 °C, with rated operational power of 132 kW at 415 V. Short-circuit protection is provided by gG type fuses rated 630 A. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.
- AF265-40-00-12
The ABB AF265-40-00-12 is a non-reversing AC contactor with four normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V at 60 Hz, with a conventional free-air thermal current of 400 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, and 250 A at 500 V and 690 V, all at 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, and 160 kW at 440 V. The control circuit voltage range is 48 to 130 V at 50 Hz, 60 Hz, and DC. Mechanical durability is 5 million operating cycles. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high, weighing 5.7 kg.