- AFC25-30-10-42
The ABB AFC25-30-10-42 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V at 60 °C, with rated operational power AC-3 of 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Maximum operating voltage UL/CSA for the main circuit is 600 V.
- AFC25-30-10-51
The ABB AFC25-30-10-51 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.298 kg. Per IEC 60947-4-1, conventional free-air thermal current is 35 A at 40 °C. AC-3 ratings include 25 A at 415 V, 380/400 V, and 220/230/240 V, all at 60 °C, with rated operational power of 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. UL/CSA horsepower ratings include 15 hp at 440–480 V AC three-phase and 15 hp at 550–600 V AC three-phase.
- AFC25-30-10-80
ABB AC contactor, display model AFC25-30-10-80. Manufacturer ID 1SBL211001R8010. It has 3 normally open main contacts and 1 normally open auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, each at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Maximum operating voltage UL/CSA main circuit is 600 V. Coil consumption average holding value at 50/60 Hz is 8 V·A.
- AFC25-30-10-81
ABB AC contactor, display model AFC25-30-10-81, manufacturer ID 1SBL211001R8110. It has 3 main contacts NO, 0 main contacts NC, 1 auxiliary contact NO, and 0 auxiliary contacts NC. Dimensions are 45 mm width, 77 mm depth/length, 86 mm height, and 0.309 kg net weight. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Maximum operating voltage UL/CSA is 600 V for the main circuit.
- AFC25-30-10-84
ABB AC contactor, display model AFC25-30-10-84, manufacturer ID 1SBL211001R8410. It has 3 main contacts NO, 0 main contacts NC, 1 auxiliary contact NO, and 0 auxiliary contacts NC. Dimensions are 45 mm width, 77 mm depth/length, and 86 mm height; net weight is 0.306 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V.
- AFC25-30-10-85
The ABB AFC25-30-10-85 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C for open contactors, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Coil consumption averages 8 V·A holding at 50/60 Hz, 70 V·A pull-in at 50 Hz, and 66 V·A pull-in at 60 Hz.
- AFC25-30-10-86
ABB AFC25-30-10-86 AC contactor, manufacturer ID 1SBL211001R8610. It has three normally open main contacts, no normally closed main contacts, and one normally open auxiliary contact. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C open contactors, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, each at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg.
- AFC25-30-10-88
ABB AC contactor, display model AFC25-30-10-88, manufacturer ID 1SBL211001R8810. It has three main contacts (NO) and one auxiliary contact (NO), with no NC contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.303 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Maximum operating voltage UL/CSA for the main circuit is 600 V.