- AFC25-30-10-80
ABB AC contactor, display model AFC25-30-10-80. Manufacturer ID 1SBL211001R8010. It has 3 normally open main contacts and 1 normally open auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, each at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Maximum operating voltage UL/CSA main circuit is 600 V. Coil consumption average holding value at 50/60 Hz is 8 V·A.
- AFC25-30-10-81
ABB AC contactor, display model AFC25-30-10-81, manufacturer ID 1SBL211001R8110. It has 3 main contacts NO, 0 main contacts NC, 1 auxiliary contact NO, and 0 auxiliary contacts NC. Dimensions are 45 mm width, 77 mm depth/length, 86 mm height, and 0.309 kg net weight. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Maximum operating voltage UL/CSA is 600 V for the main circuit.
- AFC25-30-10-84
ABB AC contactor, display model AFC25-30-10-84, manufacturer ID 1SBL211001R8410. It has 3 main contacts NO, 0 main contacts NC, 1 auxiliary contact NO, and 0 auxiliary contacts NC. Dimensions are 45 mm width, 77 mm depth/length, and 86 mm height; net weight is 0.306 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V.
- AFC25-30-10-85
The ABB AFC25-30-10-85 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C for open contactors, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Coil consumption averages 8 V·A holding at 50/60 Hz, 70 V·A pull-in at 50 Hz, and 66 V·A pull-in at 60 Hz.
- AFC25-30-10-86
ABB AFC25-30-10-86 AC contactor, manufacturer ID 1SBL211001R8610. It has three normally open main contacts, no normally closed main contacts, and one normally open auxiliary contact. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C open contactors, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, each at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg.
- AFC25-30-10-88
ABB AC contactor, display model AFC25-30-10-88, manufacturer ID 1SBL211001R8810. It has three main contacts (NO) and one auxiliary contact (NO), with no NC contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.303 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Maximum operating voltage UL/CSA for the main circuit is 600 V.
- AFC26-22-00-34
ABB AFC26-22-00-34 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a frequency of 50/60 Hz. The conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C. The contactor measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC26-22-00-51
ABB AC contactor AFC26-22-00-51, manufacturer ID 1SBL231501R5100. It has two main contacts NO and two main contacts NC, with no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz; rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated control circuit voltage is 400 to 415 V at 50 Hz and 480 V at 60 Hz. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. Dimensions are 45 mm width, 101 mm depth/length, 86 mm height; net weight 0.393 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.