- AFC26-22-00-34
ABB AFC26-22-00-34 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a frequency of 50/60 Hz. The conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C. The contactor measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC26-22-00-51
ABB AC contactor AFC26-22-00-51, manufacturer ID 1SBL231501R5100. It has two main contacts NO and two main contacts NC, with no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz; rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated control circuit voltage is 400 to 415 V at 50 Hz and 480 V at 60 Hz. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. Dimensions are 45 mm width, 101 mm depth/length, 86 mm height; net weight 0.393 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC26-22-00-80
The ABB AFC26-22-00-80 is a 4-pole AC contactor with screw terminals, 2 main contacts NO and 2 main contacts NC, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. Rated operational voltage for the main circuit is 690 V, with rated insulation voltage 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Rated operational current AC-1 is 45 A at 690 V and 40 °C. The control circuit coil is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC26-22-00-81
The ABB AFC26-22-00-81 is a 4-pole AC contactor with screw terminals. It has 2 normally open and 2 normally closed main contacts, with no auxiliary contacts. The rated operational voltage of the main circuit is 690 V at 50/60 Hz, and the rated control circuit voltage is 24 V at 50 Hz and 60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.402 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC26-22-00-84
The ABB AFC26-22-00-84 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.399 kg. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both control and main circuits. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 5.5 kW at 220/230/240 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC26-22-00-85
ABB AFC26-22-00-85 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, weighing 0.393 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. AC-1 ratings are 45 A at 40 °C, 40 A at 60 °C, and 32 A at 70 °C, all at 690 V. AC-3 ratings include 22 A at 380/400 V and 10.5 A at 690 V, both at 60 °C. Control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AFC26-22-00-86
The ABB AFC26-22-00-86 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated frequency is 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Rated operational current AC-1 is 45 A at 690 V and 40 degrees C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC26-22-00-88
ABB AFC26-22-00-88 AC contactor, manufacturer ID 1SBL231501R8800. It has two normally open and two normally closed main contacts, with no auxiliary contacts. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high; net weight 0.394 kg. The main circuit is rated 690 V, and the control and main circuits operate at 50/60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.