- AFC26-22-00-88
ABB AFC26-22-00-88 AC contactor, manufacturer ID 1SBL231501R8800. It has two normally open and two normally closed main contacts, with no auxiliary contacts. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high; net weight 0.394 kg. The main circuit is rated 690 V, and the control and main circuits operate at 50/60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC26-30-00-42
ABB AFC26-30-00-42 is a 3-pole AC contactor, manufacturer ID 1SBL231001R4200, with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.351 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V and 26 A at 380/400 V, both at 60 °C, and 17 A at 690 V at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 11 kW at 380/400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFC26-30-00-51
ABB AFC26-30-00-51 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, weighing 0.351 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 50 A at 40 °C. AC-3 ratings at 60 °C include 26 A at 380/400 V and 11 kW at 415 V. The contactor conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL231001R5100.
- AFC26-30-00-80
The ABB AFC26-30-00-80 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.351 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Rated operational current AC-3 is 26 A at 415 V and 26 A at 380/400 V, both at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 11 kW at 380/400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Screw terminals are used.
- AFC26-30-00-81
The ABB AFC26-30-00-81 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V, with a control circuit frequency of 50/60 Hz. Rated operational current AC-3 is 26 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 60 °C, and 17 A at 690 V at 60 °C. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V, and 15 kW at 440 V, 500 V, and 690 V. Dimensions are 45 mm wide, 86 mm deep, and 86 mm high, weighing 0.36 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00-84
ABB AFC26-30-00-84 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, weighing 0.357 kg. Rated operational voltage for the main circuit is 690 V, with a rated frequency of 50/60 Hz for both control and main circuits. Rated operational current AC-3 is 26 A at 415 V and 60 °C, 23 A at 500 V, and 17 A at 690 V. Rated operational power AC-3 is 11 kW at 415 V and 15 kW at 440 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL231001R8400.
- AFC26-30-00-85
ABB AFC26-30-00-85 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.351 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 50 A at 40 °C. AC-3 ratings include 26 A at 415 V and 60 °C, and 17 A at 690 V and 60 °C. AC-3 power ratings include 11 kW at 415 V and 15 kW at 440 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFC26-30-00-86
ABB AFC26-30-00-86 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, weighing 0.351 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-3 ratings include 26 A at 380/400 V and 60 °C, and 17 A at 690 V and 60 °C. AC-3 power ratings include 11 kW at 380/400 V and 15 kW at 440 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL231001R8600.