- AFC25-30-10-85
The ABB AFC25-30-10-85 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high, with a net weight of 0.298 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C for open contactors, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Coil consumption averages 8 V·A holding at 50/60 Hz, 70 V·A pull-in at 50 Hz, and 66 V·A pull-in at 60 Hz.
- AFC25-30-10-86
ABB AFC25-30-10-86 AC contactor, manufacturer ID 1SBL211001R8610. It has three normally open main contacts, no normally closed main contacts, and one normally open auxiliary contact. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C open contactors, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, each at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg.
- AFC25-30-10-88
ABB AC contactor, display model AFC25-30-10-88, manufacturer ID 1SBL211001R8810. It has three main contacts (NO) and one auxiliary contact (NO), with no NC contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.303 kg. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 25 A at 415 V, 380/400 V, and 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 415 V and 380/400 V, and 5.5 kW at 220/230/240 V. Maximum operating voltage UL/CSA for the main circuit is 600 V.
- AFC26-22-00-34
ABB AFC26-22-00-34 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a frequency of 50/60 Hz. The conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C. The contactor measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC26-22-00-51
ABB AC contactor AFC26-22-00-51, manufacturer ID 1SBL231501R5100. It has two main contacts NO and two main contacts NC, with no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz; rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated control circuit voltage is 400 to 415 V at 50 Hz and 480 V at 60 Hz. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. Dimensions are 45 mm width, 101 mm depth/length, 86 mm height; net weight 0.393 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC26-22-00-80
The ABB AFC26-22-00-80 is a 4-pole AC contactor with screw terminals, 2 main contacts NO and 2 main contacts NC, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.393 kg. Rated operational voltage for the main circuit is 690 V, with rated insulation voltage 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Rated operational current AC-1 is 45 A at 690 V and 40 °C. The control circuit coil is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC26-22-00-81
The ABB AFC26-22-00-81 is a 4-pole AC contactor with screw terminals. It has 2 normally open and 2 normally closed main contacts, with no auxiliary contacts. The rated operational voltage of the main circuit is 690 V at 50/60 Hz, and the rated control circuit voltage is 24 V at 50 Hz and 60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.402 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AFC26-22-00-84
The ABB AFC26-22-00-84 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.399 kg. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both control and main circuits. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 5.5 kW at 220/230/240 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.