- 140G-K3F3-D30-AA-MU
The Rockwell 140G-K3F3-D30-AA-MU is a 3-pole motor protection circuit breaker with a rated permanent current Iu of 300 A and a 400 A frame size. It uses T/M-adjustable thermal and magnetic protection, with thermal trip current Ir of 210 A and magnetic trip current Im of 1500 A. Rated impulse withstand voltage Uimp is 8 kV, insulation voltage Ui is rated 1000 V per IEC, and rated ultimate short-circuit breaking capacity Icu is 85 kA at 220...230 V AC, 50/60 Hz per IEC 60947-2. The toggle-operated device has one change-over auxiliary contact, screw front connections, IP40 protection, and dimensions of 205 mm height, 140 mm width, and 108.5 mm depth. The legacy 400 A rating is omitted because it conflicts with the 300 A structured parameter.
- 140G-K3F3-D30-SC
Rockwell motor protection circuit breaker, model 140G-K3F3-D30-SC. Rated current is 400 A. The unit is designated NOT_REPAIRABLE and is NON_STOCKED, with a stated lead time of 15. Weight is 0.999 KG. No pole count, interrupting capacity, voltage rating, or adjustable trip settings are supplied in the authoritative parameters, so those legacy claims are omitted. Dimensions are listed as 0.0 CM for height, width, and length and are therefore not stated. Preferred availability and quick turnaround are both false.
- 140G-K3X3
The Rockwell 140G-K3X3 is a 3-pole molded case circuit breaker rated 400 A. It carries a UL interrupting rating of 35 kA at 480 V and an IEC breaking capacity of 50 kA at 415 V. The device is not repairable. It complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 24.79 cm high, 25.908 cm wide, and 29.794 cm long; weight is 3.794 kg. The breaker is non-stocked and not preferred-available, with a listed lead time of 5. It is intended for circuit protection in panel configurations. No operating mechanism, accessory, or application compatibility is specified in the supplied data.
- 140G-K3X4
Product identification: ROCKWELL 140G-K3X4. The Allen-Bradley 140G-K3X4 is a K-frame motor protection circuit breaker rated 400 A with thermal magnetic or electronic protection. It provides 50 kA breaking capacity at 415 V and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Adjustment type is frame only. The unit is not repairable. Dimensions are 25.001 mm high, 24.501 mm wide, and 28.999 mm long.
- 140G-K6F3-D30-CJ-MU
The ROCKWELL 140G-K6F3-D30-CJ-MU is a three-pole motor protection circuit breaker with a toggle control element and a 400 A frame size. It is a complete device with protection unit, rated permanent current Iu 300 A, thermal trip current Ir 210 A, and magnetic trip current Im 1500 A. Thermal trip rating is 300 A at ambient temperature 40 °C. It has no integrated undervoltage release and no integrated earth fault protection. Rated impulse withstand voltage is 8 kV; insulation voltage is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity is IEC 60947-2: 70 kA at 400...415 V AC, 50/60 Hz.
- 140G-K6F3-D30-SA-AA
The Rockwell 140G-K6F3-D30-SA-AA is a 3-pole motor protection circuit breaker with a toggle control element and one change-over auxiliary contact. It is a complete device with a protection unit, without integrated undervoltage release or earth fault protection. Rated permanent current Iu is 300 A, with a 400 A frame size and 80% MCCB current range. Thermal trip current Ir is 210 A and magnetic trip current Im is 1500 A. Rated impulse withstand voltage Uimp is 8 kV; insulation voltage Ui is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. IEC 60947-2 Icu is 70 kA at 400 to 415 V AC, 50/60 Hz.
- 140G-K6F3-D30-Z1-CA
The Rockwell 140G-K6F3-D30-Z1-CA is a 3-pole motor protection circuit breaker with a toggle control element and an integrated protection unit. It has a rated permanent current Iu of 300 A, a thermal trip current Ir of 210 A, and a magnetic trip current Im of 1500 A. The thermal trip rating is 300 A at an ambient temperature of 40 °C. It provides a rated impulse withstand voltage Uimp of 8 kV, a rated insulation voltage Ui of 1000 V per IEC, and a maximum reverse-fed voltage of 690 V AC per IEC. Interrupting ratings include 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA, and an Icu of 70 kA at 400 to 415 V AC, 50/60 Hz per IEC 60947-2. It has three change-over auxiliary contacts, no integrated undervoltage release, and no integrated earth fault protection.
- 140G-K6F3-D40-Z1-SJ-AA
Rockwell motor protection circuit breaker, model 140G-K6F3-D40-Z1-SJ-AA. Three-pole device with toggle control and one change-over auxiliary contact. Rated permanent current Iu is 400 A; thermal trip current Ir is 280 A and magnetic trip current Im is 2000 A. Thermal trip rating is 400 A at 40 °C ambient. Rated impulse withstand voltage Uimp is 8 kV; insulation voltage Ui is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity Icu is 70 kA at 400 to 415 V AC, 50/60 Hz per IEC 60947-2. No integrated undervoltage release or earth fault protection. Watt loss for the thermal-magnetic type is 58.5 W.