- 140G-K6F3-D30-Z1-CA
The Rockwell 140G-K6F3-D30-Z1-CA is a 3-pole motor protection circuit breaker with a toggle control element and an integrated protection unit. It has a rated permanent current Iu of 300 A, a thermal trip current Ir of 210 A, and a magnetic trip current Im of 1500 A. The thermal trip rating is 300 A at an ambient temperature of 40 °C. It provides a rated impulse withstand voltage Uimp of 8 kV, a rated insulation voltage Ui of 1000 V per IEC, and a maximum reverse-fed voltage of 690 V AC per IEC. Interrupting ratings include 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA, and an Icu of 70 kA at 400 to 415 V AC, 50/60 Hz per IEC 60947-2. It has three change-over auxiliary contacts, no integrated undervoltage release, and no integrated earth fault protection.
- 140G-K6F3-D40-Z1-SJ-AA
Rockwell motor protection circuit breaker, model 140G-K6F3-D40-Z1-SJ-AA. Three-pole device with toggle control and one change-over auxiliary contact. Rated permanent current Iu is 400 A; thermal trip current Ir is 280 A and magnetic trip current Im is 2000 A. Thermal trip rating is 400 A at 40 °C ambient. Rated impulse withstand voltage Uimp is 8 kV; insulation voltage Ui is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity Icu is 70 kA at 400 to 415 V AC, 50/60 Hz per IEC 60947-2. No integrated undervoltage release or earth fault protection. Watt loss for the thermal-magnetic type is 58.5 W.
- 140G-K6H3-D30-AA
The ROCKWELL 140G-K6H3-D30-AA is a motor protection circuit breaker rated 400 A. It is not repairable. Dimensions are 26.2 cm height, 24.4 cm width, and 28.6 cm length, with a weight of 5.348 kg.
- 140G-K6H3-D40-SD-AA
The Rockwell 140G-K6H3-D40-SD-AA is a 3-pole motor protection circuit breaker with a rated permanent current Iu of 400 A and a 400 frame size. It uses a toggle control element and includes one auxiliary change-over contact. It does not have an integrated under voltage release or integrated earth fault protection. The complete device includes a protection unit. Rated impulse withstand voltage Uimp is 8 kV, and insulation voltage Ui is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity Icu is 70 kA at 400 to 415 V AC, 50/60 Hz per IEC 60947-2.
- 140G-K6I3-D30-SD-CA
The Rockwell 140G-K6I3-D30-SD-CA is a motor protection circuit breaker rated 400 A. It is not repairable. The unit weighs 0.999 kg. This device is intended for motor protection applications within industrial electrical systems.
- 140G-K6K3-D40-UC-CJ
The Rockwell 140G-K6K3-D40-UC-CJ is a motor protection circuit breaker. Its rated current is 400 A. The unit is classified as not repairable. It is not marked for preferred availability or quick turnaround, and its stock status is non-stocked. The stated lead time is 15. The recorded weight is 0.999 KG. Recorded dimensions are 0.0 height, 0.0 width, and 0.0 length, in CM. No further electrical, mechanical, or performance ratings, standards, certifications, applications, or accessories are supplied for this item. The model designation is given as 140G-K6K3-D40-UC-CJ under the Rockwell brand.
- 140G-K6X3-Z1
The Rockwell 140G-K6X3-Z1 is a 3-pole motor protection circuit breaker in the K-frame with a 400 A rating and 100% rated frame-only adjustment. It is UL Listed, CSA Certified, and CE marked, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Interrupting ratings are 65 kA at 480 V (UL) and 70 kA at 415 V (IEC). Dimensions are 24.638 cm high, 25.146 cm wide, and 29.337 cm long; weight is 3.71 kg. The device is not repairable and is non-stocked, with a lead time of 42. Preferred availability and quick turnaround are false.
- 140G-KC0F3-D40
The Rockwell 140G-KC0F3-D40 is a 3-pole motor protection circuit breaker with a rated permanent current Iu of 400 A and a 400 A frame size. It uses a T/M-adjustable thermal/adjustable magnetic (TMA) protection unit, with thermal trip current Ir of 280 A and magnetic trip current Im of 2000 A. Rated impulse withstand voltage Uimp is 8 kV, and insulation voltage is rated 1000 V per IEC. Rated short-circuit breaking capacity Icu at 400 V, 50 Hz is 120 kA; rated ultimate short-circuit breaking capacity per IEC 60947-2 is 85 kA at 500 V AC, 50/60 Hz. The device has a toggle control element, front-side screw connections, IP40 protection, and dimensions 205 mm high, 140 mm wide, 108.5 mm deep.