- 140G-KC0H3-D40
The Rockwell 140G-KC0H3-D40 is a 3-pole motor protection circuit breaker with a 400 A rated permanent current (Iu) and a 400 A frame size. It is a complete device with an electronic protection unit and a toggle control element. Rated short-circuit breaking capacity (Icu) is 120 kA at 400 V, 50 Hz, and rated impulse withstand voltage (Uimp) is 8 kV. Electronic long-time protection is adjustable from I1 = 0.4 to 1 x In (160 to 400 A) with t1 = 3, 6, 12, or 18 s; instantaneous protection is I3 = 1 to 10 x In (600 to 4800 A). Electrical life is 7000 operations at 400 A or 5000 at 600 A at 415 V AC. No integrated undervoltage release or earth fault protection is included.
- 140G-KC0X3
The Rockwell 140G-KC0X3 is a 400 A, K-Frame motor protection circuit breaker. It is a 3-pole molded case circuit breaker frame with a UL interrupting rating of 100kA at 480V. The device is not repairable. It is not preferred availability and not quick turnaround, and stock status is non-stocked. Dimensions are 24.0 cm height, 24.8 cm width, and 28.5 cm length; weight is 3.81 kg. Standards compliance is UL489, CSA22.2 No. 5, and IEC 60947-2. Lead time is 47.
- 140G-KC6X3
The Rockwell 140G-KC6X3 is a 400 A K-frame molded case circuit breaker. It is rated 65 kA at 480 V per UL and carries UL489, CSA22.2 No. 5, and IEC 60947-2 designations. Dimensions are 24.0 cm height, 24.8 cm width, and 28.5 cm length, with a weight of 3.81 kg. The unit is classified as not repairable and is non-stocked. No interrupting rating is stated for voltages other than 480 V, and no accessories, operating mechanisms, or current-limiting function are specified in the supplied data.
- 140G-KTF3-D30
Rockwell motor protection circuit breaker, model 140G-KTF3-D30. Adjustment type: adjustable thermal and adjustable magnetic. Current rating: 400 A. Certifications: UL Listed, CSA Certified, CE. The unit is not repairable. Dimensions: 12.29 cm height, 16.41 cm width, 19.51 cm length. Weight: 1.107 kg. Stock status: non-stocked; preferred availability and quick turnaround are both false. Lead time: 5.
- 140G-KTF3-D40
The Rockwell 140G-KTF3-D40 is a thermal magnetic trip unit rated 400 A for molded case circuit breakers. It provides adjustable thermal and adjustable magnetic protection. The unit is listed to UL489, CSA22.2 No. 5, and IEC 60947-2. It is designated NOT_REPAIRABLE. Dimensions are 16.21 cm height, 12.7 cm width, and 19.2 cm length; weight is 1.098 kg. The trip unit is categorized as a motor protection circuit breaker. Stock status is STOCKED, with a stated lead time of 41. Preferred availability and quick turnaround are both false.
- 140G-KTF4-D30
The Rockwell 140G-KTF4-D30 is a 4-pole molded case circuit breaker trip unit with a 400 A K-frame rating and 300 A thermal magnetic protection. It uses adjustable thermal and adjustable magnetic adjustment. Certifications include UL Listed, CSA Certified, CE, and CCC. Standards compliance includes UL489, CSA22.2 No. 5, and IEC 60947-2. The unit is not repairable. Dimensions are 22.499 cm length, 18.001 cm width, and 11.999 cm height; weight is 1.438 kg. Stock status is non-stocked, preferred availability is false, and quick turnaround is false. Listed lead time is 42.
- 140G-KTH3-D30
The Rockwell 140G-KTH3-D30 is a three-pole molded case circuit breaker with a 400 A K-Frame rating and a 300 A trip unit. It uses electronic LSI protection and is rated for an impulse withstand voltage of 8 kV, with an operating frequency range of 50 to 60 Hz. The unit is UL Listed, CSA Certified, CE, and CCC, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 19.507 cm width, 16.205 cm length, and 11.913 cm height, with a weight of 1.4 kg. It is not repairable.
- 140G-KTH3-D40
The Rockwell 140G-KTH3-D40 is an electronic motor protection circuit breaker with a 400 A trip unit rating in the K-Frame size. It is listed to UL489, CSA22.2 No. 5, and IEC 60947-2, and carries UL Listed, CSA Certified, and CE certifications. Dimensions are 13.208 cm height, 16.002 cm width, and 19.558 cm length, with a weight of 1.41 KG. The unit is not repairable. It is non-stocked, not preferred availability, and not quick turnaround, with a lead time of 5.