- 140G-KTF4-D30
The Rockwell 140G-KTF4-D30 is a 4-pole molded case circuit breaker trip unit with a 400 A K-frame rating and 300 A thermal magnetic protection. It uses adjustable thermal and adjustable magnetic adjustment. Certifications include UL Listed, CSA Certified, CE, and CCC. Standards compliance includes UL489, CSA22.2 No. 5, and IEC 60947-2. The unit is not repairable. Dimensions are 22.499 cm length, 18.001 cm width, and 11.999 cm height; weight is 1.438 kg. Stock status is non-stocked, preferred availability is false, and quick turnaround is false. Listed lead time is 42.
- 140G-KTH3-D30
The Rockwell 140G-KTH3-D30 is a three-pole molded case circuit breaker with a 400 A K-Frame rating and a 300 A trip unit. It uses electronic LSI protection and is rated for an impulse withstand voltage of 8 kV, with an operating frequency range of 50 to 60 Hz. The unit is UL Listed, CSA Certified, CE, and CCC, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 19.507 cm width, 16.205 cm length, and 11.913 cm height, with a weight of 1.4 kg. It is not repairable.
- 140G-KTH3-D40
The Rockwell 140G-KTH3-D40 is an electronic motor protection circuit breaker with a 400 A trip unit rating in the K-Frame size. It is listed to UL489, CSA22.2 No. 5, and IEC 60947-2, and carries UL Listed, CSA Certified, and CE certifications. Dimensions are 13.208 cm height, 16.002 cm width, and 19.558 cm length, with a weight of 1.41 KG. The unit is not repairable. It is non-stocked, not preferred availability, and not quick turnaround, with a lead time of 5.
- 140G-KTI4-D30
The Rockwell 140G-KTI4-D30 is an electronic motor protection circuit breaker trip unit with LSIG adjustment. It has a 400 A K-frame rating and a 300 A trip unit rating. Certifications include UL Listed, CSA Certified, CE, and CCC. It complies with UL489, CSA22.2 No. 5, and IEC 60947-2. The unit is not repairable. Dimensions are 11.999 cm height, 18.001 cm width, and 22.499 cm length; weight is 1.858 kg. Stock status is non-stocked, with a lead time of 5. Preferred availability and quick turnaround are false.
- 140G-KTI4-D40
The Rockwell 140G-KTI4-D40 is a 400 A K-Frame electronic trip unit with LSIG adjustment. It is a 4-pole molded case circuit breaker trip unit. The trip unit rating is 400 A. It is not repairable. Dimensions are 11.684 cm height, 17.78 cm width, and 24.892 cm length; weight is 1.78 kg. Standards compliance includes UL489, CSA22.2 No. 5, and IEC 60947-2. The product is non-stocked, with a lead time of 38. Preferred availability and quick turnaround are false.
- 140G-KTK3-D30
Rockwell motor protection circuit breaker, model 140G-KTK3-D30, with a 400 A K-Frame rating and electronic protection. Adjustment type is LSIG-MM. The device is a 3-pole circuit breaker. It is UL Listed, CSA Certified, CE compliant, and CCC compliant. Standards compliance includes UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 16.129 cm height, 12.827 cm width, and 19.431 cm length; weight is 1.449 kg. The unit is not repairable. It is non-stocked, not preferred availability, and not quick turnaround. Lead time is 42. No manufacturer part number or order code is supplied.
- 140G-KTK4-D30
The Rockwell 140G-KTK4-D30 is a 4-pole electronic LSIG trip unit rated 300 A, intended for K-frame applications with a 400 A K-frame rating. It is UL Listed, CSA Certified, CE, and CCC marked, and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 18.415 cm height, 12.446 cm width, and 22.987 cm length; weight is 1.83 kg. The unit is not repairable and is non-stocked. Lead time is 49. Preferred availability and quick turnaround are false.
- 140G-M-ECM
The Rockwell 140G-M-ECM is a 3-pole end cap accessory for 140G series molded case circuit breakers. It is listed to UL489, CSA22.2 No. 5, and IEC 60947-2. Dimensions are 3.899 cm height, 17.6 cm width, and 20.399 cm length; weight is 0.14 kg. The item is not repairable, is non-stocked, and has a lead time of 5. It is not marked for preferred availability or quick turnaround. No trip unit, operating mechanism, or other configuration options are specified in the supplied data.