- 140G-K3X4
Product identification: ROCKWELL 140G-K3X4. The Allen-Bradley 140G-K3X4 is a K-frame motor protection circuit breaker rated 400 A with thermal magnetic or electronic protection. It provides 50 kA breaking capacity at 415 V and complies with UL489, CSA22.2 No. 5, and IEC 60947-2. Adjustment type is frame only. The unit is not repairable. Dimensions are 25.001 mm high, 24.501 mm wide, and 28.999 mm long.
- 140G-K6F3-D30-CJ-MU
The ROCKWELL 140G-K6F3-D30-CJ-MU is a three-pole motor protection circuit breaker with a toggle control element and a 400 A frame size. It is a complete device with protection unit, rated permanent current Iu 300 A, thermal trip current Ir 210 A, and magnetic trip current Im 1500 A. Thermal trip rating is 300 A at ambient temperature 40 °C. It has no integrated undervoltage release and no integrated earth fault protection. Rated impulse withstand voltage is 8 kV; insulation voltage is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity is IEC 60947-2: 70 kA at 400...415 V AC, 50/60 Hz.
- 140G-K6F3-D30-SA-AA
The Rockwell 140G-K6F3-D30-SA-AA is a 3-pole motor protection circuit breaker with a toggle control element and one change-over auxiliary contact. It is a complete device with a protection unit, without integrated undervoltage release or earth fault protection. Rated permanent current Iu is 300 A, with a 400 A frame size and 80% MCCB current range. Thermal trip current Ir is 210 A and magnetic trip current Im is 1500 A. Rated impulse withstand voltage Uimp is 8 kV; insulation voltage Ui is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. IEC 60947-2 Icu is 70 kA at 400 to 415 V AC, 50/60 Hz.
- 140G-K6F3-D30-Z1-CA
The Rockwell 140G-K6F3-D30-Z1-CA is a 3-pole motor protection circuit breaker with a toggle control element and an integrated protection unit. It has a rated permanent current Iu of 300 A, a thermal trip current Ir of 210 A, and a magnetic trip current Im of 1500 A. The thermal trip rating is 300 A at an ambient temperature of 40 °C. It provides a rated impulse withstand voltage Uimp of 8 kV, a rated insulation voltage Ui of 1000 V per IEC, and a maximum reverse-fed voltage of 690 V AC per IEC. Interrupting ratings include 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA, and an Icu of 70 kA at 400 to 415 V AC, 50/60 Hz per IEC 60947-2. It has three change-over auxiliary contacts, no integrated undervoltage release, and no integrated earth fault protection.
- 140G-K6F3-D40-Z1-SJ-AA
Rockwell motor protection circuit breaker, model 140G-K6F3-D40-Z1-SJ-AA. Three-pole device with toggle control and one change-over auxiliary contact. Rated permanent current Iu is 400 A; thermal trip current Ir is 280 A and magnetic trip current Im is 2000 A. Thermal trip rating is 400 A at 40 °C ambient. Rated impulse withstand voltage Uimp is 8 kV; insulation voltage Ui is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity Icu is 70 kA at 400 to 415 V AC, 50/60 Hz per IEC 60947-2. No integrated undervoltage release or earth fault protection. Watt loss for the thermal-magnetic type is 58.5 W.
- 140G-K6H3-D30-AA
The ROCKWELL 140G-K6H3-D30-AA is a motor protection circuit breaker rated 400 A. It is not repairable. Dimensions are 26.2 cm height, 24.4 cm width, and 28.6 cm length, with a weight of 5.348 kg.
- 140G-K6H3-D40-SD-AA
The Rockwell 140G-K6H3-D40-SD-AA is a 3-pole motor protection circuit breaker with a rated permanent current Iu of 400 A and a 400 frame size. It uses a toggle control element and includes one auxiliary change-over contact. It does not have an integrated under voltage release or integrated earth fault protection. The complete device includes a protection unit. Rated impulse withstand voltage Uimp is 8 kV, and insulation voltage Ui is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity Icu is 70 kA at 400 to 415 V AC, 50/60 Hz per IEC 60947-2.
- 140G-K6I3-D30-SD-CA
The Rockwell 140G-K6I3-D30-SD-CA is a motor protection circuit breaker rated 400 A. It is not repairable. The unit weighs 0.999 kg. This device is intended for motor protection applications within industrial electrical systems.