- 140G-K6F3-D30-CJ-MU
The ROCKWELL 140G-K6F3-D30-CJ-MU is a three-pole motor protection circuit breaker with a toggle control element and a 400 A frame size. It is a complete device with protection unit, rated permanent current Iu 300 A, thermal trip current Ir 210 A, and magnetic trip current Im 1500 A. Thermal trip rating is 300 A at ambient temperature 40 °C. It has no integrated undervoltage release and no integrated earth fault protection. Rated impulse withstand voltage is 8 kV; insulation voltage is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity is IEC 60947-2: 70 kA at 400...415 V AC, 50/60 Hz.
- 140G-K6F3-D30-SA-AA
The Rockwell 140G-K6F3-D30-SA-AA is a 3-pole motor protection circuit breaker with a toggle control element and one change-over auxiliary contact. It is a complete device with a protection unit, without integrated undervoltage release or earth fault protection. Rated permanent current Iu is 300 A, with a 400 A frame size and 80% MCCB current range. Thermal trip current Ir is 210 A and magnetic trip current Im is 1500 A. Rated impulse withstand voltage Uimp is 8 kV; insulation voltage Ui is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. IEC 60947-2 Icu is 70 kA at 400 to 415 V AC, 50/60 Hz.
- 140G-K6F3-D30-Z1-CA
The Rockwell 140G-K6F3-D30-Z1-CA is a 3-pole motor protection circuit breaker with a toggle control element and an integrated protection unit. It has a rated permanent current Iu of 300 A, a thermal trip current Ir of 210 A, and a magnetic trip current Im of 1500 A. The thermal trip rating is 300 A at an ambient temperature of 40 °C. It provides a rated impulse withstand voltage Uimp of 8 kV, a rated insulation voltage Ui of 1000 V per IEC, and a maximum reverse-fed voltage of 690 V AC per IEC. Interrupting ratings include 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA, and an Icu of 70 kA at 400 to 415 V AC, 50/60 Hz per IEC 60947-2. It has three change-over auxiliary contacts, no integrated undervoltage release, and no integrated earth fault protection.
- 140G-K6F3-D40-Z1-SJ-AA
Rockwell motor protection circuit breaker, model 140G-K6F3-D40-Z1-SJ-AA. Three-pole device with toggle control and one change-over auxiliary contact. Rated permanent current Iu is 400 A; thermal trip current Ir is 280 A and magnetic trip current Im is 2000 A. Thermal trip rating is 400 A at 40 °C ambient. Rated impulse withstand voltage Uimp is 8 kV; insulation voltage Ui is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity Icu is 70 kA at 400 to 415 V AC, 50/60 Hz per IEC 60947-2. No integrated undervoltage release or earth fault protection. Watt loss for the thermal-magnetic type is 58.5 W.
- 140G-K6H3-D30-AA
The ROCKWELL 140G-K6H3-D30-AA is a motor protection circuit breaker rated 400 A. It is not repairable. Dimensions are 26.2 cm height, 24.4 cm width, and 28.6 cm length, with a weight of 5.348 kg.
- 140G-K6H3-D40-SD-AA
The Rockwell 140G-K6H3-D40-SD-AA is a 3-pole motor protection circuit breaker with a rated permanent current Iu of 400 A and a 400 frame size. It uses a toggle control element and includes one auxiliary change-over contact. It does not have an integrated under voltage release or integrated earth fault protection. The complete device includes a protection unit. Rated impulse withstand voltage Uimp is 8 kV, and insulation voltage Ui is rated 1000 V per IEC. Interrupting rating is 65 kA at 480 V AC, 50/60 Hz per NEMA, UL, and CSA. Rated ultimate short-circuit breaking capacity Icu is 70 kA at 400 to 415 V AC, 50/60 Hz per IEC 60947-2.
- 140G-K6I3-D30-SD-CA
The Rockwell 140G-K6I3-D30-SD-CA is a motor protection circuit breaker rated 400 A. It is not repairable. The unit weighs 0.999 kg. This device is intended for motor protection applications within industrial electrical systems.
- 140G-K6K3-D40-UC-CJ
The Rockwell 140G-K6K3-D40-UC-CJ is a motor protection circuit breaker. Its rated current is 400 A. The unit is classified as not repairable. It is not marked for preferred availability or quick turnaround, and its stock status is non-stocked. The stated lead time is 15. The recorded weight is 0.999 KG. Recorded dimensions are 0.0 height, 0.0 width, and 0.0 length, in CM. No further electrical, mechanical, or performance ratings, standards, certifications, applications, or accessories are supplied for this item. The model designation is given as 140G-K6K3-D40-UC-CJ under the Rockwell brand.