- 150-F251NBDD
The Rockwell Allen-Bradley 150-F251NBDD is an SMC Flex soft starter with a 251 A controller rating (100–200 HP at 460 V AC). It operates on 200–480 V AC input, with control voltage of 100–240 V AC and 50/60 Hz power-circuit operating frequency. The unit includes a display and supports brake control. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Overload current is 84 A for line-connected devices and 145 A for delta-connected devices. The transformer control module is rated 75 VA at 100–240 V AC (-15%, +10%). Maximum line-connected motor power is 75 kW at 230 V AC, 50 Hz, 3-phase.
- 150-F251NBR
The Rockwell 150-F251NBR is an SMC Flex smart motor controller configured as a soft starter with integral bypass and single-direction function. It is rated 251 A, 100–200 HP at 460 V AC, three-phase, with a rated operational voltage of 200–480 V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit. Control voltage is 24 V AC/DC. Line-connected motor current is 84–251 A at 600/Y/690 V AC, three-phase; delta-connected motor current is 145–435 A at 500/575 V AC, three-phase. Overload current is 84 A line-connected and 145 A delta-connected. Trip classes are 10, 15, 20, and 30. The controller includes a display, integrated motor overload protection, and status indication for stopped, starting, stopping, at speed, alarm, and fault.
- 150-F251NCD
The Rockwell 150-F251NCD is a SMC Flex soft starter with a 251 A controller rating for 100–200 HP motors at 460V AC. It has a rated operational voltage of 200...600V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit, control voltage of 100...240V AC, and operates at 50/60 Hz. Line-connected motor current is 84...251 A at 600/Y/690V AC, 3-phase; delta-connected current is 145...435 A at 500/575V AC, 3-phase. It includes a display, integrated motor overload protection, internal bypass, and trip classes 10, 15, 20, and 30. Enclosure is open type, three poles, dimensions 225 mm width, 253.8 mm depth, 560 mm height.
- 150-F251NCDB
The Rockwell 150-F251NCDB is an SMC Flex smart motor controller configured as a soft starter with pump control and an integrated display. It is rated 251 A, 100–200 Hp at 460V AC, with a rated operational voltage of 200...600V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit, and 50/60 Hz operating frequency. Line-connected motor current is 84...251 A at 600/Y/690V AC, 3-phase; delta-connected motor current is 145...435 A at 500/575V AC, 3-phase. Control voltage is 100...240V AC. Integrated motor overload protection is included, with trip classes 10, 15, 20 and 30. The open-type enclosure measures 225 mm wide, 253.8 mm deep and 560 mm high.
- 150-F251NCR
The Rockwell 150-F251NCR is a SMC Flex soft starter with an open-type enclosure, rated 251 A and 100–200 Hp at 460V AC. It operates on 200–600V AC (-15%, +10%) per UL/CSA/NEMA, 50/60 Hz, 3-phase, with 24V AC/DC control voltage. Line-connected motor current is 84–251 A at 600/Y/690V AC; delta-connected current is 145–435 A at 500/575V AC. It includes an integrated bypass, integrated motor overload protection, and a display. Trip classes are 10, 15, 20, and 30, with trip current at 117% of motor FLC. Dimensions are 225 mm wide, 253.8 mm deep, and 560 mm high. Operating temperature is -5 to 50 °C (23 to 122 °F).
- 150-F251NCRD
The Rockwell 150-F251NCRD is an SMC Flex smart motor controller configured as a soft starter with a rated current of 251 A and a controller rating of 251 A, 100–200 Hp at 460 V AC. It operates on a rated operational voltage of 200–600 V AC (-15%, +10%) per UL/CSA/NEMA for the power circuit, with a control voltage of 24 V AC/DC. The controller includes an LCD display and keypad, integrated motor overload protection, and internal bypass. Trip classes are 10, 15, 20, and 30, with a trip current rating of 117% of motor FLC. It supports line-connected motor current of 84–251 A at 600/Y/690 V AC, 3-phase, and delta-connected motor current of 145–435 A at 500/575 V AC, 3-phase. The open-type enclosure has dimensions of 225 mm width, 253.8 mm depth, and 560 mm height.
- 150-F251NZD
The Rockwell 150-F251NZD is an SMC Flex soft starter with an integrated display. Its controller rating is 251 A and 100–200 Hp at 460V AC. The power circuit operates at 50/60 Hz, and the control voltage is 100...240V AC. The rated operating voltage Ue is 230 V, with rated control supply voltage of 100 at both AC 50 Hz and AC 60 Hz. Overload current is 84 A for line-connected devices and 145 A for delta-connected devices. Trip classes are 10, 15, 20 and 30, with trip current rating 117% of motor FLC. Maximum line-connected motor power is 75 kW at 230V AC, 50Hz, 3-phase; maximum delta-connected motor power is 400Hp at 575V AC, 60 Hz, 3-phase.
- 150-F25FCDB-20E-HC3
The Rockwell 150-F25FCDB-20E-HC3 is a smart motor controller. Its stated voltage rating is 600 V AC. A second parameter lists a current value of 100 V AC; because the unit is volts rather than amperes, this value is omitted as inconsistent. The controller is supplied in a NEMA Type 4/12 (IP65) enclosure. It is classified as not repairable. Dimensions are listed as 0.0 for height, width, and length, and weight is 0.999 KG. Stock status is non-stocked, preferred availability is false, quick turnaround is false, and lead time is 29. No manufacturer part number or order code is supplied.