- 150-F251NZD
The Rockwell 150-F251NZD is an SMC Flex soft starter with an integrated display. Its controller rating is 251 A and 100–200 Hp at 460V AC. The power circuit operates at 50/60 Hz, and the control voltage is 100...240V AC. The rated operating voltage Ue is 230 V, with rated control supply voltage of 100 at both AC 50 Hz and AC 60 Hz. Overload current is 84 A for line-connected devices and 145 A for delta-connected devices. Trip classes are 10, 15, 20 and 30, with trip current rating 117% of motor FLC. Maximum line-connected motor power is 75 kW at 230V AC, 50Hz, 3-phase; maximum delta-connected motor power is 400Hp at 575V AC, 60 Hz, 3-phase.
- 150-F25FCDB-20E-HC3
The Rockwell 150-F25FCDB-20E-HC3 is a smart motor controller. Its stated voltage rating is 600 V AC. A second parameter lists a current value of 100 V AC; because the unit is volts rather than amperes, this value is omitted as inconsistent. The controller is supplied in a NEMA Type 4/12 (IP65) enclosure. It is classified as not repairable. Dimensions are listed as 0.0 for height, width, and length, and weight is 0.999 KG. Stock status is non-stocked, preferred availability is false, quick turnaround is false, and lead time is 29. No manufacturer part number or order code is supplied.
- 150-F25NBD
The Rockwell Allen-Bradley 150-F25NBD is a SMC Flex soft starter with an integrated display. It is rated 25 A and 5–15 Hp at 460V AC, with a maximum line-connected motor power of 7.5Hp at 230V AC, 60 Hz, three-phase. Control voltage is 100...240V AC; the transformer control module draws 75VA at 100...240V AC (-15%, +10%). The power circuit operates at 50/60 Hz, with a repetitive peak inverse voltage rating of 1400V per UL/CSA/NEMA and RC snubber DV/DT protection. Trip classes are 10, 15, 20 and 30, with trip current at 117% of motor FLC. Overload current is 5 A for line-connected and 8.6 A for delta-connected devices. Control options: none.
- 150-F25NBDB
The Rockwell 150-F25NBDB is a 25 A soft starter in the SMC Flex product family, rated 5–15 Hp at 460 V AC. It operates on 200–480 V AC, 3-phase, 50/60 Hz power, with a control voltage of 100–240 V AC. The controller includes a display and supports pump control. Trip classes are 10, 15, 20, and 30, with a trip current rating of 117% of motor FLC. Overload current is 5 A for line-connected devices and 8.6 A for delta-connected devices. Maximum line-connected motor power is 7.5 Hp at 230 V AC, 60 Hz, 3-phase. The power circuit includes an RC snubber network for DV/DT protection and a repetitive peak inverse voltage rating of 1400 V per UL/CSA/NEMA.
- 150-F25NBR
The Rockwell Allen-Bradley 150-F25NBR is a SMC Flex soft starter with an integrated display. It is rated 25 A and 5-15 Hp at 460 V AC, with a line-connected motor power maximum of 7.5 Hp at 230 V AC, 60 Hz, three-phase. Control voltage is 24 V AC/DC; rated control supply voltage is 24 V at both 50 Hz and 60 Hz. The power circuit operates at 50/60 Hz with a rated operating voltage Ue of 200 V. Overload current is 5 A for line-connected devices and 8.6 A for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current rating 117% of motor FLC. Control options are none.
- 150-F25NBRB
The Rockwell 150-F25NBRB is an SMC Flex soft starter with a 25 A controller rating and 5–15 Hp at 460 V AC. It uses 24 V AC/DC control voltage, with rated control supply voltage of 24 V at both 50 Hz and 60 Hz. The power circuit operates at 50/60 Hz, and the rated operating voltage Ue is 200. Line-connected motor power is 7.5 Hp at 230 V AC, 60 Hz, three-phase. Overload current is 5 for line-connected devices and 8.6 for delta-connected devices. Trip classes are 10, 15, 20, and 30, with trip current rating 117% of motor FLC. Control options include pump control, and a display is included.
- 150-F25NBRD
The Rockwell 150-F25NBRD is a SMC Flex soft starter with an integrated display. It is rated 25 A and 5–15 Hp at 460 V AC, with a maximum line-connected motor power of 7.5 Hp at 230 V AC, 60 Hz, three-phase. Control voltage is 24 V AC/DC; rated control supply voltage is 24 V at both 50 Hz and 60 Hz. The controller provides selectable trip classes 10, 15, 20, and 30, and a trip current rating of 117% of motor full load current. Overload current is 5 A for line-connected devices and 8.6 A for delta-connected devices. Power-circuit operating frequency is 50/60 Hz. The power circuit includes an RC snubber network for DV/DT protection and a repetitive peak inverse voltage rating of 1400 V per UL/CSA/NEMA.
- 150-F25NCD
The ROCKWELL 150-F25NCD is an SMC Flex soft starter for three-phase motor control, rated 25 A and 5-15 Hp at 460V AC. Control voltage is 100...240V AC. The controller includes an LCD display and keypad. Power circuit operating frequency is 50/60 Hz, with rated operational voltage 200...600V AC (-15%, +10%) per UL/CSA/NEMA. Line connected motor current is 5...25A at 500/575V AC, three-phase; delta connected motor current is 8.7...43A at 500/575V AC, three-phase. Integrated motor overload protection is included, with trip classes 10, 15, 20 and 30. Enclosure is open type, IP20 per IEC for the power circuit. Operating temperature is -5 to 50 degrees C (23 to 122 degrees F).