Industrial Automation Parts. Prompt replies from real people.

ROCKWELL 150-F251NCD Smart Motor Controller

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ROCKWELL 150-F251NCD?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ROCKWELL 150-F251NCD cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
150-F251NCD
Material Number
—
Manufacturer
ROCKWELL
Product ID
107512

Get a Free Quote

Request pricing and availability for 150-F251NCD.

More parts to source? Send your whole list in one enquiry

Key specifications

Control Voltage
100...240V AC
Rated operating voltage Ue
200
DV/DT protection
RC snubber network for power circuit
Operating frequency
50/60 Hz for power circuit
Rated operational current
3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Weight
30.8
See all specifications

Product Highlights

  1. Current and Power Ratings: 251 A controller rating with 100-200 Hp at 460V AC, line-connected motor current 84...251 A at 600/Y/690V AC, and delta-connected motor current 145...435 A at 500/575V AC
  2. Control Voltage and Frequency: 100...240V AC control voltage and 50/60 Hz operating frequency for the power circuit
  3. Soft Starter Design: SMC Flex soft starter with internal bypass, single-direction function, and 3 poles
  4. Overload and Trip Protection: Integrated motor overload protection with trip classes 10, 15, 20 and 30 and trip current rating 117% of motor FLC
  5. Short-Circuit Protection: Standard fuse, circuit breaker and high capacity time delay class CC/J/L devices, with maximum available fault current 70kA at 600V or 690V
  6. Display and Status Indication: Integrated display with status indication for stopped, starting, stopping, at speed, alarm and fault
  7. Operating Conditions: Open-type enclosure with operating temperature -5 to 50 °C, storage and transportation temperature -20 °C, and humidity 5...95% noncondensing
150-F251NCD

Product Information

Technical Specifications

Specifications for 150-F251NCD

ParameterValue
Control Voltage100...240V AC
Controller Rating251 A 100-200Hp @ 460V AC
Product FamilySMC Flex
With displayYes
Voltage type for actuatingAC
Rated operating voltage Ue200
Rated control supply voltage at AC 50 Hz100
Rated control supply voltage at AC 60 Hz100
Overload current for line connected devices84 A
Overload current for delta connected devices145 A
Controller typeSoft starter
Control optionsNone
Trip classes10, 15, 20 and 30
Trip current rating117% of motor FLC
Transformer control module75VA @ 100...240V AC (-15%, +10%)
Heatsink fan rating40VA @ 110/120V AC or 220/240V AC
DV/DT protectionRC snubber network for power circuit
Repetitive peak inverse voltage rating1600V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz for power circuit
Line connected motor power, max75 kW @ 230V AC @ 50Hz, 3-phase
Delta connected motor power, max400Hp @ 575V AC, 60 Hz, 3-phase
Rated impulse voltage6000V per IEC for power circuit
Dielectric withstand2500V per IEC for power circuit
Line connected motor current84...251 A @ 600/Y/690V AC, 3-phase
Delta connected motor current145...435A @ 500/575V AC, 3-phase
Ampere tested european style, max6,9 gRB 73xxx630 6,6URD33xxx700 @ 690V for maximum FLC
Ampere tested north american style, maxA070URD33xxx700 @ 690V for maximum FLC
Transient protectionMetal oxide varistors: 220 J (optional) for power circuit
Insulation voltageRated 500V per IEC for power circuit
Rated operational voltage200...600V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current<10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device listStandard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts1 for auxiliary contacts
High capacity available fault current, max70kA @ 600V, maximum current 800 A time delay Class J or Class L fuse for inside delta connected motors
Type of currentAC for auxiliary contacts
Conventional thermal current (Ith)AC/DC: 5 A for auxiliary contacts
Type of control circuitElectromagnetic relay for auxiliary contacts
Type of contactsProgmable NO/NC for auxiliary contacts
Utilization categoryMG 1 per UL/CSA/NEMA for power circuit
Standard controller featureStatus indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max70kA @ 690V for maximum FLC
Optional controller featureSMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motor’s full-load current rating
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
Number of sensors, max6 for PTC input ratings
Inrush current control module5A @ 24V DC (-15%, +10%)
ParameterValue
Voltage at PTC terminals (RPTC = open), max30V for PTC input ratings
Transient watts control module60 W @ 24V DC (-15%, +10%)
Steady state watts control module24 W @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = 4 kΩ), max<7.5 for PTC input ratings
Response time800 ms for PTC input ratings
Inrush time control module250 ms @ 24V DC (-15%, +10%)
Transient time control module500 ms @ 24V DC (-15%, +10%)
Cold resistance of PTC sensor chain, max1500 ? for PTC input ratings
Tachometer input0...5V DC @ 4.5V DC = 100% Speed
Allen bradley power supply control module, min1606-XLP50E @ 24V DC (-15%, +10%)
Short circuit trip resistance25 ? ± 10 ? for PTC input ratings
Response resistance3400 ? ± 150 ? for PTC input ratings
Reset resistance1600 ? ± 100 ? for PTC input ratings
Input OFF-state voltage, max50V AC @ 10V DC/12V AC for control circuit
Input ON-state voltage, min85V AC @ 19.2V DC/20.4V AC for control circuit
Rated operational current3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts
Input ON-state current20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit
Contact typeAuxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)
Steady state heat dissipation with control and fan power198 W
Storage and transportation temperature-20
Humidity5...95% (noncondensing)
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
Protection against electrical shockIP2X (with terminal covers) per IEC for power circuit
EMC emission levelsRadiated emission: Class A
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2
Altitude2000 m
Pollution degree2
Weight30.8
ShockOpsal: 5.5 G
Width225 mm (8.86 in)
Depth253.8 mm (9.99 in)
Height560 mm (22.05 in)
Power pole constructionHeatsink hockey puck thyristor modular design
VibrationOpsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make3600VA for auxiliary contacts
Break360VA for auxiliary contacts
Internal bypassYes
FunctionSingle direction
Power terminal markingsNEMA, CENELEC EN50 012
Control terminalsClAing yoke connection, M3 screw clA
Line/load side power terminalsTwo M10 x 1.5 diam holes per power pole
Number of poles3
EnclosureOpen type
Control modules constructionThermoset and thermoplastic moldings
Metal parts constructionPlated brass, copper or painted steel
RepairableREPAIRABLE
Preferred Availabilityfalse
Quick Turnaroundfalse
Dimension Height38.1
Lead Time21
Dimension Width30.988
Dimension Length35.992
Stock StatusSTOCKED
Weight UnitKG
Dimension UnitCM

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
Allen-Bradley 150-F251NCD Smart Motor Controller