S120 Combi Type A Is Cancelled — and Its Replacement Is Not a Drop-In
| Date | Milestone | What it means for FTA owners |
|---|---|---|
| 1 October 2025 | P.M400 — phase-out announced | The SINAMICS S120 Combi Frame Type A (FTA) modules entered phase-out; the original announcement is Siemens Industry Support entry 109994613, referenced in the cancellation notice [1] |
| 30 September 2026 | Last factory orders as a “new part” | The final date by which a new-part order had to reach the factory [1] |
| 1 October 2026 | P.M410 — product cancellation | FTA production is cancelled; responsibility passes to Customer Services, and repair services and spare-parts delivery continue from this point [1] |
| 1 October 2035 | P.M490 — product discontinuation (anticipated) | The date Siemens currently expects repair and spare-parts support for FTA to end [1] |
Four dates, and the second one has already passed. That is what makes the S120 Combi FTA announcement different from most phase-out notices we cover: by the time the cancellation milestone arrived on 1 October 2026, the window for ordering an FTA module as a new part had already closed the day before [1]. If you run a compact lathe or milling machine built around one of these combined drive modules, you cannot order your way back to safety. What you can still do — for almost nine more years, on Siemens' current schedule — is repair, source spares, and plan. This article sets out exactly which modules are affected, why the newer Frame Type B is not a simple swap, and where we think the sensible money goes.
![SINAMICS S120 Combi Power Module. Siemens product image (image code P_NC01_XX_01674, via a dealer-hosted copy); the Combi integrates the line infeed, spindle and feed power units in a single module [3].](https://api.indprt.com/static/images/article_images/admin_c3c5789bad1ec743e254f1cdfe005b40.jpg)
SINAMICS S120 Combi Power Module. Siemens product image (image code P_NC01_XX_01674, via a dealer-hosted copy); the Combi integrates the line infeed, spindle and feed power units in a single module [3].
A drive built for compact machine tools
The S120 Combi was never a general-purpose drive. Siemens describes it as a very compact and rugged drive concept tailored for compact turning and milling machines: it integrates a line infeed with regenerative feedback capability, the power units for the spindle and feed motors, and a TTL encoder interface into a single Power Module [3]. The range is optimised as a drive for three to six axes in machine tools, and a Combi module can be expanded with SINAMICS S120/S220 Motor Modules in booksize format when a machine needs more axes [3].
That integration is precisely why the FTA cancellation matters more than the module's modest power ratings suggest. In a conventional S120 line-up, a failed infeed and a failed motor module are separate spares on separate shelves. In a Combi machine, the infeed, the spindle output and the feed outputs live in one housing with one article number. When that housing fails, the whole machine stops — and the replacement question is never “which module”, it is “this exact Combi, a repair, or a redesign”. Thousands of compact CNC lathes and mills were built around that one-box idea, which is why so many of them are still cutting metal long after the machine builder moved on to newer controls.
Exactly what was cancelled: seven modules and four FTA-only accessories
The cancellation covers the seven FTA power modules and the four accessories made only for FTA [1]:
| Product | Article number | Specification in the announcement |
|---|---|---|
| S120 Combi FTA A01 | 6SL3111-3VE21-6FA2 | 16 kW, 18 A, 9 A, 9 A |
| S120 Combi FTA A02 | 6SL3111-3VE21-6EA1 | 16 kW, 24 A, 9 A, 9 A |
| S120 Combi FTA A03 | 6SL3111-3VE22-0HA1 | 20 kW, 30 A, 9 A, 9 A |
| S120 Combi FTA A04 | 6SL3111-4VE21-6FA2 | 16 kW, 18 A, 9 A, 9 A, 9 A |
| S120 Combi FTA A05 | 6SL3111-4VE21-6EA1 | 16 kW, 24 A, 9 A, 9 A, 9 A |
| S120 Combi FTA A06 | 6SL3111-4VE22-0HA1 | 20 kW, 30 A, 12 A, 9 A, 9 A |
| S120 Combi FTA A07 | 6SL3111-4VE21-0EA1 | 10 kW, 24 A, 12 A, 12 A, 12 A |
| FTA external fan unit | 6SL3161-0EP00-0AA0 | External fan unit for FTA only |
| FTA reinforcement plate | 6SL3161-1LP00-0AA0 | Reinforcement plate for FTA only |
| FTA terminal kit | 6SL3161-8AP00-0AA1 | Terminal kit for FTA only |
| FTA drip protection grid | 6SL3161-3DP00-0AA0 | Drip protection grid for FTA only |
Source: article numbers and specifications as listed in [1]. The A01–A03 units are the three-axis versions (spindle plus two feed outputs); A04–A07 add a third feed output. Read the current columns carefully before assuming two machines in the same shop run the same Combi: an A01 and an A02 share the 16 kW infeed rating but differ on the spindle output (18 A against 24 A) [1].
The accessories deserve a second look. The external fan unit, reinforcement plate, terminal kit and drip protection grid are FTA-only parts, and they are cancelled with the modules [1]. A spare FTA module on the shelf without its fan unit and terminal kit is a partial spare. If your spares audit counts power modules only, it is undercounting what a field swap actually consumes.

A SINAMICS S120 Combi FTA module (6SL3111-4VE22-0HA1, the A06 variant) photographed from the side, rating label at lower right. Dealer listing photograph; the label, not the housing colour, is what identifies an FTA unit.
Frame Type B stays on sale — and Siemens says plainly that it is not a hard substitution
Siemens is explicit about the way forward, and equally explicit about its limit. The S120 Combi FTB products will remain available, but “due to the improved performance, optimized dimensions and the design differences, hard substitution is not available between FTA and FTB”, and users are asked to select and migrate to FTB modules according to their specific requirements [1]. The cancellation notice points readers to the SINAMICS S120 Combi manual, to the FTB product note and to a dedicated FTA/FTB differences document for the detail [1].
The current FTB new-module release lists six power modules [2]:
| FTB module | Article number | Rating in the release |
|---|---|---|
| B11 | 6SL3111-3VE21-6FC1 | 16 kW / 18 / 9 / 9 A |
| B12 | 6SL3111-3VE21-6EC1 | 16 kW / 24 / 9 / 9 A |
| B13 | 6SL3111-3VE22-0HC1 | 20 kW / 30 / 9 / 9 A |
| B14 | 6SL3111-4VE21-6FC1 | 16 kW / 18 / 9 / 9 / 9 A |
| B16 | 6SL3111-4VE22-0HC1 | 20 kW / 30 / 12 / 9 / 9 A |
| B17 | 6SL3111-4VE21-6ED2 | 16 kW / 24 / 12 / 9 / 9 A |
Source: sales and delivery release for the FTB new modules [2], which also releases a 16 kW line reactor (6SL3100-0EE21-6AB0) and an extension axis adapter (6SL3161-3XP00-0AA0) as option parts. Put the two tables side by side and the temptation is obvious: B11 reads like A01, B12 like A02, B13 like A03. Resist reading them as equivalents. Siemens' own wording rules out a hard substitution, and the stated reasons — performance, dimensions and design — are exactly the three things that decide whether a drive fits an existing machine cabinet, cooling concept and parameter set [1]. Treat the FTB table as a shortlist for an engineering assessment, never as a cross-reference.
This is also where the FTA story diverges from the larger S120 phase-out we covered yesterday in the Chassis-2 and Cabinet Modules-2 announcement. There, Siemens set only the first milestone and gave no cancellation or discontinuation dates at all. Here, the full staircase is published — phase-out, cancellation and an anticipated discontinuation nine years later — which makes FTA one of the more plannable S120 retirements, provided the planning actually happens. The wider platform context is in our coverage of Siemens completing its next-generation SINAMICS G platform.
What P.M410 changes in practice — and what it does not
Three things changed on 1 October 2026. First, FTA left active sale as a new part: the last new-part orders had to be placed at the factory by 30 September 2026 [1]. Second, responsibility for the range passed to Customer Services [1]. Third, from that date Siemens continues to provide repair services and spare-parts delivery for the FTA modules until the anticipated P.M490 discontinuation on 1 October 2035 [1].
Just as important is what did not change. Nothing in the notice shortens the working life of an installed FTA module, withdraws repair support, or sets an earlier end date for spares: the support horizon in the document runs to 2035 [1]. Nor does the notice claim that an FTB module can be parameterised and dropped into an FTA machine without engineering work — it says the opposite [1]. Any claim you hear that “FTA support ends next year” or that “the B-type is a plug-in replacement” goes beyond what Siemens has published, in one direction or the other.
The cost of getting this wrong is concentrated in a single failure. ITIC's 2024 survey of more than 1,000 enterprises found over 90 percent estimating hourly downtime costs above $300,000, with 41 percent putting the figure between $1 million and $5 million or more — self-reported enterprise figures that exclude litigation and fines, and a ceiling rather than a typical small machine shop's number [4]. A compact machining centre earns its keep by the spindle hour, and a Combi failure is a whole-machine stop, not a single-axis stop. The arithmetic that matters is not the enterprise ceiling; it is your own machine's hourly contribution against the price of one shelf spare bought while FTA units are still circulating.
Our judgement: repair and spares first, redesign only on evidence
Our position, stated as judgement: for most installed FTA machines, the rational order is spares first, repair second, FTB migration third — and the nine-year support window is a reason to sequence that work calmly, not to postpone it indefinitely. A shelf spare in the exact FTA article number your machine runs removes the only scenario that truly hurts: a mid-job Combi failure with no unit to fit. Repair through the Customer Services channel Siemens describes [1] covers the failures a spare does not. An FTB migration, by contrast, is a small redesign project — dimensions, performance and design all differ [1] — and it earns its engineering hours when a machine is being rebuilt anyway, when its FTA spare has been consumed, or when a second failure makes the pattern undeniable.
Start with the rating plate. Record the full article number of every Combi in service, check it against the eleven cancelled numbers above, and count the FTA-only accessories alongside the modules. INDPRT sources Siemens parts across the SINAMICS and SIMATIC ranges — see the Siemens brand page — and a quote request quoting the full article number from the plate is the fastest way to check current sourcing options for a specific FTA unit. The cancellation is already in force; the support clock, on Siemens' own dates, runs to 2035. Use it deliberately, and the FTA retirement stays a managed expense instead of becoming an emergency.
Sources
[1] Siemens Industry Support, entry 110005001: Product cancellation (P.M410) announcement of SINAMICS S120 Combi Frame Type A — phase-out timeline, affected article numbers, phase-out process and the statement that hard substitution between FTA and FTB is not available. https://support.industry.siemens.com/cs/document/110005001/product-cancellation-(p-m410)-announcement-of-sinamics-s120-combi-frame-type-a?dti=0&lc=en-US [2] Siemens Industry Support, entry 109976001: Sales and delivery release for SINAMICS S120 Combi FTB New Modules — the six released FTB power modules and two option parts. https://support.industry.siemens.com/cs/document/109976001/sales-and-delivery-release-for-sinamics-s120-combi-ftb-new-modules?dti=0&lc=en-US [3] Siemens SiePortal: SINAMICS S120 Combi Power Modules — product positioning, integrated infeed and axis concept, three-to-six-axis optimisation and expansion with booksize Motor Modules. https://sieportal.siemens.com/en-ww/products-services/10231162 [4] ITIC 2024 Hourly Cost of Downtime Report. https://itic-corp.com/itic-2024-hourly-cost-of-downtime-report/
Need help finding a part?
Send your model and quantity. Our team aims to reply promptly during office hours.