- XLBM800A/1250A Cable shroud down
ABB XLBM800A/1250A Cable shroud down is an industrial catalog item. Key specifications include Environmental Information: 1SEP501008P0001, Product Net Weight: 0.1 kg, Object Classification Code: Q, and ETIM 8: EC001040 - Fuse switch disconnector. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- XLP00
ABB XLP00 fuse type isolating switch, manufacturer ID 1SEP101890R0001. Three-pole (3P) device for NH00 and NH000 fuses in DIN fuse systems, front cover 3P handle, baseplate mounting. Rated current 160 A; rated frequency 50/60 Hz main circuit. Rated operational current AC-21B is 125 A at 690 V; AC-22B is 160 A at 500 V, 63 A at 800 V, and 125 A at 1000 V. Rated impulse withstand voltage 8 kV; rated conditional short-circuit current 50 kA rms at 690 V. Power loss 3.5 W at rated load. Dimensions 105 mm wide, 187 mm high, 90 mm deep; net weight 0.49 kg. Degree of protection IP30. Electronic fuse monitoring: No.
- XLP00-1P
ABB XLP00-1P fuse type isolating switch, one pole, baseplate mounting with lug terminals and a front cover 1P handle. It accepts NH00 and NH000 DIN fuses. Rated current is 160 A, with rated operational voltage 220 V DC, 500 V AC, and 690 V AC, and main circuit rated frequency 50/60 Hz. Rated operational currents are 125 A at 690 V AC (AC-21B), 160 A at 500 V AC (AC-22B), and 160 A at 220 V DC (DC-22B). Rated impulse withstand voltage is 8 kV, rated conditional short-circuit current is 50 kA rms at 690 V, and power loss at rated load is 3.5 W. Degree of protection is IP30. Dimensions are 40 mm wide, 88 mm high, and 185 mm deep; net weight is 0.24 kg. Standards: IEC60947-3 and GB/T14048.3. Electronic fuse monitoring is not included.
- XLP00-1P-2BC
The ABB XLP00-1P-2BC is a single-pole fuse type isolating switch with a baseplate mounting and front cover 1P handle. It accepts NH00 and NH000 DIN fuses and uses cable clamp terminals. Rated current is 160 A at 50/60 Hz, with rated operational voltages of 220 V DC, 500 V AC, and 690 V AC. Rated operational currents are 160 A at 500 V AC (AC-22B), 125 A at 690 V AC (AC-21B), and 160 A at 220 V DC (DC-22B). Rated impulse withstand voltage is 8 kV, rated conditional short-circuit current is 50 kA rms at 690 V, and power loss at rated load is 3.5 W. Dimensions are 40 mm wide, 88 mm high, and 185 mm deep; net weight is 0.28 kg. Protection degree is IP30. Standards: IEC60947-3 and GB/T14048.3.
- XLP00-1P-2M8
ABB XLP00-1P-2M8 fuse type isolating switch, manufacturer ID 1SEP600113R0003. Single-pole (1P) fuse switch disconnector for DIN fuse systems, accepting NH00 and NH000 fuse sizes. Rated current 160 A; rated operational current AC-21B is 125 A at 690 V and AC-22B is 160 A at 500 V. Main circuit rated frequency 50/60 Hz, rated impulse withstand voltage 8 kV, rated conditional short-circuit current 50 kA rms at 690 V. Power loss at rated load 3.5 W. Front cover 1P handle, baseplate mounting. Dimensions: 40 mm width, 88 mm height, 185 mm depth; net weight 0.26 kg. Degree of protection IP30. Electronic fuse monitoring: no.
- XLP00-2P
ABB XLP00-2P fuse type isolating switch, manufacturer ID 1SEP600114R0001. Two-pole (2P) fuse switch disconnector for DIN fuse system, accepting NH00 and NH000 fuse sizes. Rated current 160 A; rated operational current AC-21B 125 A at 690 V and AC-22B 160 A at 500 V. Main circuit rated frequency 50/60 Hz, rated impulse withstand voltage 8 kV, rated conditional short-circuit current 50 kA rms at 690 V. Power loss 3.5 W at rated load. Degree of protection IP30. Front cover 2P handle, baseplate mounting. Dimensions: 80 mm width, 88 mm height, 185 mm depth; net weight 0.53 kg. Electronic fuse monitoring: no.
- XLP00-2P-4BC
The ABB XLP00-2P-4BC is a 2-pole fuse type isolating switch, manufacturer ID 1SEP600114R0002. It is rated 160 A and accepts NH00 and NH000 fuses in the DIN fuse system. The main circuit is rated 50/60 Hz, with a rated impulse withstand voltage of 8 kV and a rated conditional short-circuit current of 50 kA rms at 690 V. Rated operational current is 125 A at 690 V in AC-21B and 160 A at 500 V in AC-22B. Power loss is 3.5 W at rated load. The unit has a front cover 2P handle and baseplate mounting, with IP30 protection. Dimensions are 80 mm wide, 88 mm high, and 185 mm deep; net weight is 0.61 kg. Electronic fuse monitoring is not included.
- XLP00-2P-4M8
The ABB XLP00-2P-4M8 is a 2-pole fuse type isolating switch for baseplate mounting, using NH00 or NH000 DIN fuses. It is rated 160 A at 50/60 Hz, with rated operational voltages of 220 V DC, 500 V AC, and 690 V AC. Rated operational current is 125 A at 690 V AC in AC-21B and 160 A at 500 V AC in AC-22B and at 220 V DC in DC-22B. Rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Power loss is 3.5 W at rated load. Protection is IP30. Dimensions are 80 mm wide, 88 mm high, and 185 mm deep; weight is 0.57 kg. Standards: IEC60947-3 and GB/T14048.3.