- XLP00-4P
The ABB XLP00-4P is a 4-pole fuse type isolating switch, manufacturer ID 1SEP600115R0001. It accepts NH00 and NH000 fuses in a DIN fuse system and mounts on a baseplate. The rated current is 160 A, with a rated operational voltage of 500 V AC and a rated frequency of 50/60 Hz in the main circuit. Rated operational current AC-22B is 160 A at 500 V. Rated conditional short-circuit current is 50 kA rms at 690 V, and rated impulse withstand voltage is 8 kV. Power loss is 3.5 W at rated load. Degree of protection is IP30. Dimensions are 145 mm wide, 88 mm high, and 185 mm deep; net weight is 0.83 kg. The handle type is a front cover for 4-pole units. Electronic fuse monitoring is not included.
- XLP00-4P-8BC
ABB XLP00-4P-8BC is a four-pole fuse type isolating switch, manufacturer ID 1SEP600115R0002. It is rated 160 A at 500 V AC, with a main circuit frequency of 50/60 Hz and a rated impulse withstand voltage of 8 kV. Rated conditional short-circuit current is 50 kA rms at 690 V. It accepts NH00 and NH000 fuses in the DIN system and uses a front cover 4P handle with baseplate mounting. Power loss at rated load is 3.5 W. Dimensions are 145 mm wide, 88 mm high, and 185 mm deep; net weight is 0.99 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP00-4P-8M8
The ABB XLP00-4P-8M8 is a four-pole fuse type isolating switch with manufacturer ID 1SEP600115R0003. It accepts NH00 and NH000 fuses in the DIN fuse system and is rated 160 A at 500 V AC, 50/60 Hz. Rated impulse withstand voltage for the main circuit is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Rated operational current AC-22B is 160 A at 500 V. Power loss at rated load is 3.5 W. The unit measures 145 mm wide, 88 mm high, and 185 mm deep, weighs 0.91 kg, and has IP30 degree of protection. Mounting is by baseplate with a front cover 4P handle. Electronic fuse monitoring is not included.
- XLP00-6BC
ABB XLP00-6BC fuse type isolating switch, manufacturer ID 1SEP101890R0002. Three-pole (3P) fuse switch disconnector for NH00/NH000 DIN fuses, baseplate mounting, front cover 3P handle. Rated current 160 A; rated frequency 50/60 Hz; rated impulse withstand voltage 8 kV; rated conditional short-circuit current 50 kA rms at 690 V. Rated operational current AC-21B is 125 A at 690 V; AC-22B is 160 A at 500 V, 63 A at 800 V, and 125 A at 1000 V. Power loss at rated load is 3.5 W. Degree of protection IP30. Dimensions: 105 mm width, 187 mm height, 90 mm depth; net weight 0.57 kg. Electronic fuse monitoring: no.
- XLP00-6BC-3M8
The ABB XLP00-6BC-3M8 is a 3-pole fuse type isolating switch for baseplate mounting, with a front cover 3P handle and cable clamp bolt terminals. It accepts NH00 and NH000 DIN fuses and is rated 160 A, 50/60 Hz, with a rated impulse withstand voltage of 8 kV. Rated operational currents are 125 A at 690 V AC-21B, 160 A at 500 V, 63 A at 800 V and 125 A at 1000 V AC-22B, and 125 A at 400 V AC-23B. Conditional short-circuit current is 50 kA rms at 690 V. Power loss is 3.5 W at rated load. Protection is IP30. Standards: IEC60947-3 and GB/T14048.3. Dimensions are 105 mm wide, 187 mm high and 90 mm deep; net weight 0.65 kg.
- XLP00-6M8
The ABB XLP00-6M8 is a 3-pole fuse type isolating switch with a rated current of 160 A. It accepts NH00 and NH000 fuses in a DIN fuse system and uses lug terminals, with baseplate mounting and a 3P fuse holder handle. The main circuit is rated 50/60 Hz, with a rated impulse withstand voltage of 8 kV and a rated conditional short-circuit current of 50 kA rms at 690 V. Rated operational currents include 125 A at 690 V AC-21B, 160 A at 500 V and 63 A at 800 V AC-22B, and 125 A at 400 V AC-23B. Power loss is 3.5 W at rated load. Dimensions are 105 mm wide, 187 mm high, and 90 mm deep; net weight is 0.63 kg. Degree of protection is IP30. Standards: IEC60947-3, GB/T14048.3. Electronic fuse monitoring is not included.
- XLP00-A40/120-B-3BC-below
ABB XLP00-A40/120-B-3BC-below fuse type isolating switch, manufacturer ID 1SEP101899R0002. Three-pole fuse switch disconnector for NH00/NH000 DIN fuses, rated current 160 A, rated frequency 50/60 Hz. Rated operational current AC-21B is 125 A at 690 V; AC-22B is 160 A at 500 V. Rated conditional short-circuit current is 50 kA rms at 690 V, with rated impulse withstand voltage 8 kV. Mounting is on a 40 mm busbar system; handle type is front cover 3P. Power loss at rated load is 3.5 W. Dimensions are 105 mm wide, 187 mm high, and 195 mm deep; net weight 1.2 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP00-A40/120-B-3M8-below
ABB fuse type isolating switch, display model XLP00-A40/120-B-3M8-below, manufacturer ID 1SEP101899R0004. Three-pole fuse switch disconnector for 40 mm busbar system mounting, with front cover 3P handle. Rated current 160 A; rated operational current AC-21B 125 A at 690 V and AC-22B 160 A at 500 V. Main circuit rated frequency 50/60 Hz, rated impulse withstand voltage 8 kV, rated conditional short-circuit current 50 kA rms at 690 V. Power loss 3.5 W at rated load. Fuse system DIN, fuse sizes NH00 and NH000. Degree of protection IP30. Dimensions 105 mm wide, 187 mm high, 195 mm deep; net weight 1.2 kg. Electronic fuse monitoring: no.