- XLP00-A40/120-B-3BC-below
ABB XLP00-A40/120-B-3BC-below fuse type isolating switch, manufacturer ID 1SEP101899R0002. Three-pole fuse switch disconnector for NH00/NH000 DIN fuses, rated current 160 A, rated frequency 50/60 Hz. Rated operational current AC-21B is 125 A at 690 V; AC-22B is 160 A at 500 V. Rated conditional short-circuit current is 50 kA rms at 690 V, with rated impulse withstand voltage 8 kV. Mounting is on a 40 mm busbar system; handle type is front cover 3P. Power loss at rated load is 3.5 W. Dimensions are 105 mm wide, 187 mm high, and 195 mm deep; net weight 1.2 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP00-A40/120-B-3M8-below
ABB fuse type isolating switch, display model XLP00-A40/120-B-3M8-below, manufacturer ID 1SEP101899R0004. Three-pole fuse switch disconnector for 40 mm busbar system mounting, with front cover 3P handle. Rated current 160 A; rated operational current AC-21B 125 A at 690 V and AC-22B 160 A at 500 V. Main circuit rated frequency 50/60 Hz, rated impulse withstand voltage 8 kV, rated conditional short-circuit current 50 kA rms at 690 V. Power loss 3.5 W at rated load. Fuse system DIN, fuse sizes NH00 and NH000. Degree of protection IP30. Dimensions 105 mm wide, 187 mm high, 195 mm deep; net weight 1.2 kg. Electronic fuse monitoring: no.
- XLP00-A40/75-B-3BC-below
The ABB XLP00-A40/75-B-3BC-below is a 3-pole fuse type isolating switch for DIN NH00/NH000 fuses, mounted on a 40 mm busbar system with a 3P front cover handle. It is rated 160 A, 50/60 Hz, with a rated impulse withstand voltage of 8 kV and a rated conditional short-circuit current of 50 kA rms at 690 V. Rated operational current is 125 A at 690 V in AC-21B and 160 A at 500 V in AC-22B. Power loss is 3.5 W at rated load. Dimensions are 105 mm wide, 187 mm high, and 150 mm deep; net weight is 1 kg. Degree of protection is IP30. Electronic fuse monitoring is not included. Manufacturer ID: 1SEP101898R0002.
- XLP00-A40/75-B-3M8-below
ABB fuse type isolating switch, display model XLP00-A40/75-B-3M8-below, manufacturer ID 1SEP101898R0004. Three-pole (3P) fuse switch disconnector for NH00/NH000 fuses in a DIN fuse system, with front cover 3P handle and mounting in a 40 mm busbar system. Rated current 160 A; rated frequency 50/60 Hz; rated operational current AC-22B 160 A at 500 V and AC-21B 125 A at 690 V. Rated impulse withstand voltage 8 kV; rated conditional short-circuit current 50 kA rms at 690 V. Power loss 3.5 W at rated load. Degree of protection IP30. Dimensions 105 mm wide, 187 mm high, 150 mm deep; net weight 1 kg. Electronic fuse monitoring: no.
- XLP00-A40/95-B-3BC-below
ABB fuse type isolating switch, model XLP00-A40/95-B-3BC-below, manufacturer ID 1SEP101889R0002. Three-pole (3P) fuse switch disconnector for DIN fuse systems, accepting NH00 and NH000 fuse sizes, with a front cover 3P handle and mounting on a 40 mm busbar system. Rated current is 160 A; rated operational current is 125 A at 690 V AC-21B and 160 A at 500 V AC-22B. Main circuit rated frequency is 50/60 Hz, rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Power loss at rated load is 3.5 W. Degree of protection is IP30. Dimensions are 105 mm wide, 187 mm high, and 175 mm deep; net weight is 1.1 kg. Electronic fuse monitoring is not included.
- XLP00-A60/60-A-3BC-above
The ABB XLP00-A60/60-A-3BC-above is a 3-pole fuse type isolating switch, manufacturer ID 1SEP101917R0001. It accepts NH00 and NH000 fuses in a DIN fuse system and mounts in a 60 mm busbar system with a front cover 3P handle. Rated current is 160 A at 50/60 Hz, with rated operational current AC-21B of 125 A at 690 V and AC-22B of 160 A at 500 V, 63 A at 800 V, and 125 A at 1000 V. Rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Power loss is 3.5 W at rated load. Dimensions are 105 mm wide, 206 mm high, and 126 mm deep; weight is 0.95 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP00-A60/60-B-3BC-below
The ABB XLP00-A60/60-B-3BC-below is a 3-pole fuse type isolating switch for 60 mm busbar systems, using NH00/NH000 DIN fuses. It has a rated current of 160 A and a main-circuit rated frequency of 50/60 Hz. Rated operational current is 125 A at 690 V in AC-21B, and 160 A at 500 V, 63 A at 800 V, and 125 A at 1000 V in AC-22B. Rated conditional short-circuit current is 50 kA rms at 690 V, with rated impulse withstand voltage of 8 kV. Power loss is 3.5 W at rated load. Dimensions are 105 mm wide, 206 mm high, and 126 mm deep; net weight is 0.95 kg. Degree of protection is IP30. The handle type is front cover 3P. Electronic fuse monitoring is not included.
- XLP00-A60/60-B-below
The ABB XLP00-A60/60-B-below is a 3-pole fuse type isolating switch with a rated current (In) of 160 A. It accepts NH00 and NH000 fuses in a DIN fuse system and mounts on a 60 mm busbar system. Rated operational voltage covers 400 V AC, 500 V AC, 690 V AC, 800 V AC, and 1000 V AC. Rated frequency for the main circuit is 50/60 Hz, rated impulse withstand voltage (Uimp) is 8 kV, and rated conditional short-circuit current (Inc) is 50 kA rms at 690 V. Power loss is 3.5 W at rated load. The unit has lug terminals, a front cover 3P handle, IP30 protection, and dimensions of 105 mm width, 206 mm height, and 126 mm depth, weighing 0.95 kg. It is classified under IEC60947-3 and GB/T14048.3.