- XLP00-1P-2M8
ABB XLP00-1P-2M8 fuse type isolating switch, manufacturer ID 1SEP600113R0003. Single-pole (1P) fuse switch disconnector for DIN fuse systems, accepting NH00 and NH000 fuse sizes. Rated current 160 A; rated operational current AC-21B is 125 A at 690 V and AC-22B is 160 A at 500 V. Main circuit rated frequency 50/60 Hz, rated impulse withstand voltage 8 kV, rated conditional short-circuit current 50 kA rms at 690 V. Power loss at rated load 3.5 W. Front cover 1P handle, baseplate mounting. Dimensions: 40 mm width, 88 mm height, 185 mm depth; net weight 0.26 kg. Degree of protection IP30. Electronic fuse monitoring: no.
- XLP00-2P
ABB XLP00-2P fuse type isolating switch, manufacturer ID 1SEP600114R0001. Two-pole (2P) fuse switch disconnector for DIN fuse system, accepting NH00 and NH000 fuse sizes. Rated current 160 A; rated operational current AC-21B 125 A at 690 V and AC-22B 160 A at 500 V. Main circuit rated frequency 50/60 Hz, rated impulse withstand voltage 8 kV, rated conditional short-circuit current 50 kA rms at 690 V. Power loss 3.5 W at rated load. Degree of protection IP30. Front cover 2P handle, baseplate mounting. Dimensions: 80 mm width, 88 mm height, 185 mm depth; net weight 0.53 kg. Electronic fuse monitoring: no.
- XLP00-2P-4BC
The ABB XLP00-2P-4BC is a 2-pole fuse type isolating switch, manufacturer ID 1SEP600114R0002. It is rated 160 A and accepts NH00 and NH000 fuses in the DIN fuse system. The main circuit is rated 50/60 Hz, with a rated impulse withstand voltage of 8 kV and a rated conditional short-circuit current of 50 kA rms at 690 V. Rated operational current is 125 A at 690 V in AC-21B and 160 A at 500 V in AC-22B. Power loss is 3.5 W at rated load. The unit has a front cover 2P handle and baseplate mounting, with IP30 protection. Dimensions are 80 mm wide, 88 mm high, and 185 mm deep; net weight is 0.61 kg. Electronic fuse monitoring is not included.
- XLP00-2P-4M8
The ABB XLP00-2P-4M8 is a 2-pole fuse type isolating switch for baseplate mounting, using NH00 or NH000 DIN fuses. It is rated 160 A at 50/60 Hz, with rated operational voltages of 220 V DC, 500 V AC, and 690 V AC. Rated operational current is 125 A at 690 V AC in AC-21B and 160 A at 500 V AC in AC-22B and at 220 V DC in DC-22B. Rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Power loss is 3.5 W at rated load. Protection is IP30. Dimensions are 80 mm wide, 88 mm high, and 185 mm deep; weight is 0.57 kg. Standards: IEC60947-3 and GB/T14048.3.
- XLP00-4P
The ABB XLP00-4P is a 4-pole fuse type isolating switch, manufacturer ID 1SEP600115R0001. It accepts NH00 and NH000 fuses in a DIN fuse system and mounts on a baseplate. The rated current is 160 A, with a rated operational voltage of 500 V AC and a rated frequency of 50/60 Hz in the main circuit. Rated operational current AC-22B is 160 A at 500 V. Rated conditional short-circuit current is 50 kA rms at 690 V, and rated impulse withstand voltage is 8 kV. Power loss is 3.5 W at rated load. Degree of protection is IP30. Dimensions are 145 mm wide, 88 mm high, and 185 mm deep; net weight is 0.83 kg. The handle type is a front cover for 4-pole units. Electronic fuse monitoring is not included.
- XLP00-4P-8BC
ABB XLP00-4P-8BC is a four-pole fuse type isolating switch, manufacturer ID 1SEP600115R0002. It is rated 160 A at 500 V AC, with a main circuit frequency of 50/60 Hz and a rated impulse withstand voltage of 8 kV. Rated conditional short-circuit current is 50 kA rms at 690 V. It accepts NH00 and NH000 fuses in the DIN system and uses a front cover 4P handle with baseplate mounting. Power loss at rated load is 3.5 W. Dimensions are 145 mm wide, 88 mm high, and 185 mm deep; net weight is 0.99 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP00-4P-8M8
The ABB XLP00-4P-8M8 is a four-pole fuse type isolating switch with manufacturer ID 1SEP600115R0003. It accepts NH00 and NH000 fuses in the DIN fuse system and is rated 160 A at 500 V AC, 50/60 Hz. Rated impulse withstand voltage for the main circuit is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Rated operational current AC-22B is 160 A at 500 V. Power loss at rated load is 3.5 W. The unit measures 145 mm wide, 88 mm high, and 185 mm deep, weighs 0.91 kg, and has IP30 degree of protection. Mounting is by baseplate with a front cover 4P handle. Electronic fuse monitoring is not included.
- XLP00-6BC
ABB XLP00-6BC fuse type isolating switch, manufacturer ID 1SEP101890R0002. Three-pole (3P) fuse switch disconnector for NH00/NH000 DIN fuses, baseplate mounting, front cover 3P handle. Rated current 160 A; rated frequency 50/60 Hz; rated impulse withstand voltage 8 kV; rated conditional short-circuit current 50 kA rms at 690 V. Rated operational current AC-21B is 125 A at 690 V; AC-22B is 160 A at 500 V, 63 A at 800 V, and 125 A at 1000 V. Power loss at rated load is 3.5 W. Degree of protection IP30. Dimensions: 105 mm width, 187 mm height, 90 mm depth; net weight 0.57 kg. Electronic fuse monitoring: no.