Product Model
AX370-30-11-81
Material Number
1SFL607074R8111
Manufacturer
ABB
Product ID
93565

Get a Free Quote

Request pricing and availability for AX370-30-11-81.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
4.7 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 600 A (690 V) 55 °C 500 A (690 V) 70 °C 400 A
Rated Operational Power AC-3 (Pe)
(415 V) 200 kW (440 V) 200 kW (500 V) 250 kW (690 V) 315 kW (380 / 400 V) 200 kW (220 / 230 / 240 V) 110 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
See all specifications

Product Highlights

  1. Contact Configuration: 3 main contacts NO and 0 main contacts NC, plus 1 auxiliary contact NO and 1 auxiliary contact NC
  2. Current Ratings: Conventional free-air thermal current 250 A at 40 °C, AC-1 operational current 600 A at 690 V and 40 °C, and AC-3 operational current 370 A at 415 V and 55 °C
  3. Power and Voltage: Rated operational voltage 1000 V for the main circuit, with AC-3 rated operational power up to 315 kW at 690 V
  4. Switching Capacity: Rated breaking capacity 8 x Ie AC-3 and rated making capacity 10 x Ie AC-3, with maximum electrical and mechanical switching frequency of 300 cycles per hour
  5. Durability and Coil: Mechanical durability 5 million cycles, rated control circuit voltage 24 V at 50 Hz and 60 Hz, and coil operating limits per IEC 60947-4-1
  6. Ambient and Installation: Ambient air temperature -40 to 70 °C without thermal overload relay and -25 to 55 °C with thermal overload relay, maximum operating altitude 3000 m without derating, and main circuit bar terminals
AX370-30-11-81

Product Information

Technical Specifications

Specifications for AX370-30-11-81

ParameterValue
Product Net Width140 mm
Product Net Depth / Length180 mm
Product Net Height225 mm
Product Net Weight4.7 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 600 A (690 V) 55 °C 500 A (690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 370 A (440 V) 55 °C 370 A (500 V) 55 °C 315 A (690 V) 55 °C 315 A (380400 V) 55 °C 370 A (220230240 V) 55 °C 370 A
Rated Operational Power AC-3 (Pe)(415 V) 200 kW (440 V) 200 kW (500 V) 250 kW (690 V) 315 kW (380400 V) 200 kW (220230240 V) 110 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
ParameterValue
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
Maximum Electrical Switching Frequency300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 24 V 60 Hz 24 V
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal TypeMain Circuit: Bars
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SFL607074R8111

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.