- AX370-30-11-84
The ABB AX370-30-11-84 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 1000 V in the main circuit at 50 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 55 °C, with rated operational power AC-3 of 200 kW at 415 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 8 kV. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 4.7 kg.
- AX370-30-11-85
The ABB AX370-30-11-85 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 4.7 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 220/230/240 V, 380/400 V, 415 V, and 440 V, and 315 A at 500 V and 690 V, all at 55 °C. Rated operational power AC-3 is 200 kW at 415 V and 440 V, 250 kW at 500 V, and 315 kW at 690 V. Maximum electrical switching frequency is 300 cycles per hour.
- AX370-30-11-86
ABB AX370-30-11-86 AC contactor, manufacturer ID 1SFL607074R8611. It has 3 NO main contacts and 1 NO plus 1 NC auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 220/230/240 V, 380/400 V, 415 V, and 440 V at 55 °C, and 315 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 includes 110 kW at 220/230/240 V, 200 kW at 380/400 V, 415 V, and 440 V, 250 kW at 500 V, and 315 kW at 690 V. Maximum electrical switching frequency is 300 cycles per hour. Dimensions are 140 mm wide, 180 mm deep, 225 mm high; weight 4.7 kg.
- AX370-30-11-88
The ABB AX370-30-11-88 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 4.7 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, and 315 A at 500 V and 690 V, all at 55 °C. Maximum electrical switching frequency is 300 cycles per hour. Rated impulse withstand voltage is 8 kV.
- AX40-30-01-26
ABB AX40-30-01-26 is a 3-pole AC contactor with one normally closed auxiliary contact (3 NO main, 1 NC auxiliary). It measures 54 mm wide, 90 mm deep, and 108.3 mm high, weighing 0.667 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 65 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 40 A at 415 V and 380/400 V, and 18.5 kW at 415 V and 380/400 V. AC-1 rating is 60 A at 220/240 V and 55 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 Group C. Manufacturer ID: 1SBL321074R2601.
- AX40-30-01-36
The ABB AX40-30-01-36 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 54 mm wide, 90 mm deep, and 108.3 mm high, and weighs 0.667 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz, with a rated control circuit voltage of 190 V at 50 Hz and 220 V at 60 Hz. Rated operational current AC-3 is 40 A at 380/400 V and 415 V, 37 A at 440 V, 33 A at 500 V, and 25 A at 690 V, all at 55 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, and 22 kW at 440 V, 500 V, and 690 V. Terminals are screw type, IP20. Maximum operating altitude without derating is 3000 m.
- AX40-30-01-75
ABB AX40-30-01-75 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 54 mm wide, 90 mm deep, and 108.3 mm high, and weighs 0.667 kg. The main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 65 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 40 A at 380/400 V and 415 V, 37 A at 440 V, 33 A at 500 V, and 25 A at 690 V, all at 55 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Manufacturer ID: 1SBL321074R7501.
- AX40-30-01-80
The ABB AX40-30-01-80 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 40 A at 380/400 V and 415 V, 37 A at 440 V, 33 A at 500 V, and 25 A at 690 V, all at 55 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. Coil voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; weight is 0.667 kg. Terminals are screw type, IP20.