- AX40-30-01-80
The ABB AX40-30-01-80 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 40 A at 380/400 V and 415 V, 37 A at 440 V, 33 A at 500 V, and 25 A at 690 V, all at 55 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. Coil voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; weight is 0.667 kg. Terminals are screw type, IP20.
- AX40-30-01-81
The ABB AX40-30-01-81 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. The control circuit is rated 24 V at 50 Hz and 60 Hz. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 40 A at 380/400 V and 415 V, 37 A at 440 V, 33 A at 500 V, and 25 A at 690 V, all at 55 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, and 22 kW at 440 V, 500 V, and 690 V. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; net weight is 0.667 kg. Terminals are screw type with IP20 protection.
- AX40-30-01-84
ABB AX40-30-01-84 AC contactor, manufacturer ID 1SBL321074R8401. Block-type contactor with 3 main poles (NO) and 1 built-in auxiliary contact (NC). Coil: 110 V at 50 Hz, 110 to 120 V at 60 Hz. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz. Rated operational current AC-3: 40 A at 380/400 V and 415 V, 37 A at 440 V, 33 A at 500 V, 25 A at 690 V, all at 55 °C. Rated operational power AC-3: 18.5 kW at 380/400 V and 415 V, 22 kW at 440 V, 500 V and 690 V. Screw terminals, IP20 at main, auxiliary and coil terminals. Dimensions 54 mm wide, 90 mm deep, 108.3 mm high; net weight 0.667 kg.
- AX40-30-01-85
The ABB AX40-30-01-85 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, and a rated frequency of 50/60 Hz. Rated operational current AC-3 is 40 A at 380/400 V and 415 V, 37 A at 440 V, 33 A at 500 V, and 25 A at 690 V, all at 55 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, and 22 kW at 440 V, 500 V, and 690 V. The control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high, with a net weight of 0.667 kg. Terminals are screw type, IP20.
- AX40-30-01-86
ABB AX40-30-01-86 AC contactor, manufacturer ID 1SBL321074R8601. Three-pole contactor with 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NC. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Rated operational current AC-3 is 40 A at 380/400 V and 415 V, 37 A at 440 V, 33 A at 500 V, and 25 A at 690 V, all at 55 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, and 22 kW at 440 V, 500 V, and 690 V. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; net weight 0.667 kg. Screw terminals, IP20.
- AX40-30-01-88
The ABB AX40-30-01-88 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 40 A at 380/400 V and 415 V, 37 A at 440 V, 33 A at 500 V, and 25 A at 690 V, all at 55 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. The control circuit is rated 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Screw terminals; dimensions 54 mm wide, 90 mm deep, 108.3 mm high; net weight 0.667 kg.
- AX40-30-10-26
The ABB AX40-30-10-26 is a block-type AC contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (1 NO, 0 NC). Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 40 A at 380/400 V and 415 V (55 °C), 37 A at 440 V, 33 A at 500 V, and 25 A at 690 V. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; net weight is 0.667 kg.
- AX40-30-10-36
ABB AX40-30-10-36 AC contactor, manufacturer ID 1SBL321074R3610. Block-type design with 3 main contacts NO and 1 auxiliary contact NO. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 40 A at 380/400 V and 415 V, 55 °C, and 25 A at 690 V, 55 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, and 22 kW at 440 V, 500 V, and 690 V. Coil control voltage is 190 V at 50 Hz and 220 V at 60 Hz. Screw terminals; dimensions 54 mm width, 90 mm depth, 108.3 mm height; net weight 0.667 kg.