- AX260-30-11-88
The ABB AX260-30-11-88 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 220/230/240 V, 380/400 V, 415 V, and 440 V at 55 °C, and 250 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 includes 132 kW at 380/400 V and 415 V, 160 kW at 440 V and 500 V, and 200 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; weight 4.7 kg.
- AX300-30-11-80
ABB AX300-30-11-80 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 220/230/240 V, 380/400 V, 415 V, and 440 V at 55 °C, and 290 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 includes 90 kW at 220/230/240 V and 160 kW at 380/400 V, 415 V, and 440 V. Maximum electrical switching frequency is 300 cycles per hour. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight 4.7 kg.
- AX300-30-11-81
ABB AX300-30-11-81 AC contactor, manufacturer ID 1SFL587074R8111. Main circuit rated 1000 V at 50 Hz, with three normally open main contacts and one NO plus one NC auxiliary contact. Rated operational current AC-3 is 305 A at 415 V, 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Rated breaking capacity AC-3 is 8 x Ie and making capacity is 10 x Ie. Conventional free-air thermal current Ith is 250 A per IEC 60947-4-1 at 40 °C. Coil voltage is 24 V at 50 Hz and 60 Hz. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight 4.7 kg.
- AX300-30-11-83
The ABB AX300-30-11-83 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 250 A at 40 °C for open contactors. AC-1 ratings at 690 V are 500 A at 40 °C, 400 A at 55 °C, and 325 A at 70 °C. AC-3 ratings at 55 °C include 305 A at 415 V and 290 A at 690 V, with rated operational power up to 250 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 4.7 kg.
- AX300-30-11-84
ABB AX300-30-11-84 AC contactor, manufacturer ID 1SFL587074R8411. Three normally open main contacts, one normally open and one normally closed auxiliary contact. Main circuit rated operational voltage 1000 V at 60 Hz. Conventional free-air thermal current per IEC 60947-4-1, open contactors at 40 °C ambient: 250 A. Rated operational current AC-3: 305 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C; 290 A at 500 V and 690 V at 55 °C. Rated operational power AC-3: 160 kW at 415 V, 440 V, and 380/400 V; 200 kW at 500 V; 250 kW at 690 V; 90 kW at 220/230/240 V. Rated insulation voltage 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage 8 kV. Maximum electrical switching frequency 300 cycles per hour. Dimensions 140 x 180 x 225 mm, 4.7 kg.
- AX300-30-11-85
The ABB AX300-30-11-85 is a 3-pole AC contactor with 3 normally open main contacts, 1 normally open auxiliary contact, and 1 normally closed auxiliary contact. It has a rated operational voltage of 1000 V for the main circuit and a rated frequency of 60 Hz. The conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V; 290 A at 55 °C for 500 V and 690 V. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V; 200 kW at 500 V; 250 kW at 690 V; and 90 kW at 220/230/240 V. Dimensions are 140 mm width, 180 mm depth, and 225 mm height, with a net weight of 4.7 kg.
- AX300-30-11-86
ABB AX300-30-11-86 AC contactor, manufacturer ID 1SFL587074R8611. Three normally open main contacts, no normally closed main contacts, plus one normally open and one normally closed auxiliary contact. Main circuit rated operational voltage 1000 V at 60 Hz. Conventional free-air thermal current per IEC 60947-4-1 for open contactors at 40 °C is 250 A. Rated operational current AC-3 is 305 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V; 290 A at 55 °C for 500 V and 690 V. Rated operational power AC-3 is 90 kW at 220/230/240 V, 160 kW at 380/400 V, 415 V, and 440 V, 200 kW at 500 V, and 250 kW at 690 V. Dimensions 140 mm wide, 180 mm deep, 225 mm high; weight 4.7 kg.
- AX300-30-11-88
The ABB AX300-30-11-88 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 60 Hz. Rated operational current AC-3 is 305 A at 415 V and 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Maximum electrical and mechanical switching frequency is 300 cycles per hour, with mechanical durability of 5 million operations. Dimensions are 140 mm width, 180 mm depth, and 225 mm height, weighing 4.7 kg. Rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz.