- AX300-30-11-81
ABB AX300-30-11-81 AC contactor, manufacturer ID 1SFL587074R8111. Main circuit rated 1000 V at 50 Hz, with three normally open main contacts and one NO plus one NC auxiliary contact. Rated operational current AC-3 is 305 A at 415 V, 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Rated breaking capacity AC-3 is 8 x Ie and making capacity is 10 x Ie. Conventional free-air thermal current Ith is 250 A per IEC 60947-4-1 at 40 °C. Coil voltage is 24 V at 50 Hz and 60 Hz. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight 4.7 kg.
- AX300-30-11-83
The ABB AX300-30-11-83 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 1000 V at 50 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 250 A at 40 °C for open contactors. AC-1 ratings at 690 V are 500 A at 40 °C, 400 A at 55 °C, and 325 A at 70 °C. AC-3 ratings at 55 °C include 305 A at 415 V and 290 A at 690 V, with rated operational power up to 250 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 4.7 kg.
- AX300-30-11-84
ABB AX300-30-11-84 AC contactor, manufacturer ID 1SFL587074R8411. Three normally open main contacts, one normally open and one normally closed auxiliary contact. Main circuit rated operational voltage 1000 V at 60 Hz. Conventional free-air thermal current per IEC 60947-4-1, open contactors at 40 °C ambient: 250 A. Rated operational current AC-3: 305 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C; 290 A at 500 V and 690 V at 55 °C. Rated operational power AC-3: 160 kW at 415 V, 440 V, and 380/400 V; 200 kW at 500 V; 250 kW at 690 V; 90 kW at 220/230/240 V. Rated insulation voltage 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage 8 kV. Maximum electrical switching frequency 300 cycles per hour. Dimensions 140 x 180 x 225 mm, 4.7 kg.
- AX300-30-11-85
The ABB AX300-30-11-85 is a 3-pole AC contactor with 3 normally open main contacts, 1 normally open auxiliary contact, and 1 normally closed auxiliary contact. It has a rated operational voltage of 1000 V for the main circuit and a rated frequency of 60 Hz. The conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V; 290 A at 55 °C for 500 V and 690 V. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V; 200 kW at 500 V; 250 kW at 690 V; and 90 kW at 220/230/240 V. Dimensions are 140 mm width, 180 mm depth, and 225 mm height, with a net weight of 4.7 kg.
- AX300-30-11-86
ABB AX300-30-11-86 AC contactor, manufacturer ID 1SFL587074R8611. Three normally open main contacts, no normally closed main contacts, plus one normally open and one normally closed auxiliary contact. Main circuit rated operational voltage 1000 V at 60 Hz. Conventional free-air thermal current per IEC 60947-4-1 for open contactors at 40 °C is 250 A. Rated operational current AC-3 is 305 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V; 290 A at 55 °C for 500 V and 690 V. Rated operational power AC-3 is 90 kW at 220/230/240 V, 160 kW at 380/400 V, 415 V, and 440 V, 200 kW at 500 V, and 250 kW at 690 V. Dimensions 140 mm wide, 180 mm deep, 225 mm high; weight 4.7 kg.
- AX300-30-11-88
The ABB AX300-30-11-88 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 60 Hz. Rated operational current AC-3 is 305 A at 415 V and 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Maximum electrical and mechanical switching frequency is 300 cycles per hour, with mechanical durability of 5 million operations. Dimensions are 140 mm width, 180 mm depth, and 225 mm height, weighing 4.7 kg. Rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz.
- AX32-30-01-26
The ABB AX32-30-01-26 is a block-type AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 65 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 28 A at 500 V, and 21 A at 690 V, all at 55 °C. Corresponding AC-3 power ratings range from 9 kW at 220/230/240 V to 18.5 kW at 440 V, 500 V, and 690 V. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; weight is 0.667 kg.
- AX32-30-01-36
The ABB AX32-30-01-36 is a 3-pole block-type AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has screw terminals and measures 54 mm wide, 90 mm deep, and 108.3 mm high, weighing 0.667 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C; corresponding AC-3 power is 15 kW at 380/400 V and 415 V. Conventional free-air thermal current is 65 A per IEC 60947-4-1 at 40 °C. Terminal protection is IP20 per IEC 60529. Maximum operating altitude without derating is 3000 m.