- AX300-30-11-88
The ABB AX300-30-11-88 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 60 Hz. Rated operational current AC-3 is 305 A at 415 V and 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Maximum electrical and mechanical switching frequency is 300 cycles per hour, with mechanical durability of 5 million operations. Dimensions are 140 mm width, 180 mm depth, and 225 mm height, weighing 4.7 kg. Rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz.
- AX32-30-01-26
The ABB AX32-30-01-26 is a block-type AC contactor with three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 65 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 28 A at 500 V, and 21 A at 690 V, all at 55 °C. Corresponding AC-3 power ratings range from 9 kW at 220/230/240 V to 18.5 kW at 440 V, 500 V, and 690 V. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; weight is 0.667 kg.
- AX32-30-01-36
The ABB AX32-30-01-36 is a 3-pole block-type AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has screw terminals and measures 54 mm wide, 90 mm deep, and 108.3 mm high, weighing 0.667 kg. Rated operational voltage is 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C; corresponding AC-3 power is 15 kW at 380/400 V and 415 V. Conventional free-air thermal current is 65 A per IEC 60947-4-1 at 40 °C. Terminal protection is IP20 per IEC 60529. Maximum operating altitude without derating is 3000 m.
- AX32-30-01-75
The ABB AX32-30-01-75 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 54 mm wide, 90 mm deep, and 108.3 mm high, and weighs 0.667 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 65 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 32 A at 415 V and 55 °C, with rated operational power AC-3 of 15 kW at 415 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C).
- AX32-30-01-80
The ABB AX32-30-01-80 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. The control circuit is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Main and auxiliary circuits are rated 690 V at 50 or 60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, and 21 A at 690 V, all at 55 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, and 18.5 kW at 440 V, 500 V, and 690 V. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; net weight is 0.667 kg. Terminals are screw type, IP20.
- AX32-30-01-81
ABB AX32-30-01-81 AC contactor, manufacturer ID 1SBL281074R8101. Three main contacts NO, zero main contacts NC, one auxiliary contact NC. Rated operational voltage 690 V for both main and auxiliary circuits, rated frequency 50/60 Hz. Coil voltage 24 V at 50 Hz and 24 V at 60 Hz. Rated operational current AC-3: 32 A at 415 V, 32 A at 440 V, 28 A at 500 V, and 21 A at 690 V, all at 55 °C. Rated operational power AC-3: 15 kW at 415 V, 18.5 kW at 440 V, 18.5 kW at 500 V, and 18.5 kW at 690 V. Dimensions 54 mm wide, 90 mm deep, 108.3 mm high; net weight 0.667 kg. Screw terminals, IP20 at main, auxiliary, and coil terminals. Maximum operating altitude 3000 m without derating.
- AX32-30-01-83
The ABB AX32-30-01-83 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. Its coil is rated 48 V at 50 Hz and 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits, with rated frequency 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, 220/230/240 V, and 28 A at 500 V, and 21 A at 690 V, all at 55 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Dimensions are 54 mm width, 90 mm depth, and 108.3 mm height; net weight 0.667 kg. Terminals are screw type, IP20.
- AX32-30-01-84
ABB AX32-30-01-84 AC contactor, block-type, with 3 main poles (NO) and 1 built-in auxiliary contact (NC). Coil: 110 V at 50 Hz, 110 to 120 V at 60 Hz. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz. Rated operational current AC-3: 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 28 A at 500 V, 21 A at 690 V, all at 55 °C. Rated operational power AC-3: 15 kW at 380/400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, 9 kW at 220/230/240 V. Dimensions 54 x 90 x 108.3 mm; net weight 0.667 kg. Screw terminals; IP20 at main, auxiliary, and coil terminals.