- AX32-30-01-85
ABB AC contactor, display model AX32-30-01-85, manufacturer ID 1SBL281074R8501. It has three main poles (3 NO, 0 NC) and one auxiliary NC contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V (55 °C), 28 A at 500 V, and 21 A at 690 V. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; net weight 0.667 kg. Screw terminals, IP20.
- AX32-30-01-86
The ABB AX32-30-01-86 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has screw terminals and measures 54 mm wide, 90 mm deep, and 108.3 mm high, weighing 0.667 kg. The rated operational voltage is 690 V for both main and auxiliary circuits, at 50 or 60 Hz. The rated control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Rated operational current AC-3 is 32 A at 415 V and 440 V, and rated operational power AC-3 is 15 kW at 415 V. Maximum operating altitude without derating is 3000 m.
- AX32-30-01-88
ABB AX32-30-01-88 AC contactor, manufacturer ID 1SBL281074R8801. Three main contacts NO, zero main contacts NC, one auxiliary contact NC. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz. Rated operational current AC-3: 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, each at 55 °C; 28 A at 500 V and 21 A at 690 V, each at 55 °C. Rated operational power AC-3: 15 kW at 380/400 V and 415 V; 18.5 kW at 440 V, 500 V, and 690 V; 9 kW at 220/230/240 V. Rated control circuit voltage: 230 to 240 V at 50 Hz, 240 to 260 V at 60 Hz. Screw terminals. Dimensions 54 mm width, 90 mm depth, 108.3 mm height; net weight 0.667 kg.
- AX32-30-10-26
The ABB AX32-30-10-26 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 54 mm wide, 90 mm deep, and 108.3 mm high, and weighs 0.667 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 65 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 32 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C).
- AX32-30-10-36
The ABB AX32-30-10-36 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, and a rated frequency of 50/60 Hz. Conventional free-air thermal current is 65 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C. Maximum mechanical switching frequency is 3600 cycles per hour. The contactor uses screw terminals, measures 54 mm wide, 90 mm deep, and 108.3 mm high, and weighs 0.667 kg.
- AX32-30-10-75
The ABB AX32-30-10-75 is an AC contactor with three main NO poles and one built-in auxiliary NO contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V and 21 A at 690 V, both at 55 °C; rated operational power AC-3 is 15 kW at 415 V and 18.5 kW at 690 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high, weighing 0.667 kg. Terminals are screw type. The coil operates at 200 V 50 Hz or 200 to 220 V 60 Hz. Maximum mechanical switching frequency is 3600 cycles per hour.
- AX32-30-10-80
The ABB AX32-30-10-80 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 54 mm wide, 90 mm deep, and 108.3 mm high, and weighs 0.667 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, and 21 A at 690 V. Rated operational power AC-3 is 15 kW at 415 V and 380/400 V, and 18.5 kW at 440 V, 500 V, and 690 V. The control circuit voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Terminals are screw type, IP20.
- AX32-30-10-81
The ABB AX32-30-10-81 is an AC contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (1 NO, 0 NC). It has a rated operational voltage of 690 V for both main and auxiliary circuits, and a rated frequency of 50/60 Hz. The rated control circuit voltage is 24 V at 50 Hz and 24 V at 60 Hz. Rated operational current AC-3 is 32 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, and 21 A at 690 V. Rated operational power AC-3 is 15 kW at 415 V and 380/400 V, and 18.5 kW at 440 V, 500 V, and 690 V. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high, with a net weight of 0.667 kg. Terminals are screw type.