Q1Can you supply the ABB AX32-30-01-88?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AX32-30-01-88 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AX32-30-01-88
Material Number
1SBL281074R8801
Manufacturer
ABB
Product ID
74602

Get a Free Quote

Request pricing and availability for AX32-30-01-88.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.667 kg
Rated Operational Voltage
Auxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 55 A (690 V) 40 °C 55 A (690 V) 70 °C 39 A
Rated Operational Power AC-3 (Pe)
(415 V) 15 kW (440 V) 18.5 kW (500 V) 18.5 kW (690 V) 18.5 kW (380 / 400 V) 15 kW (220 / 230 / 240 V) 9 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A for 0.1 s 140 A for 1 s 100 A
See all specifications

Product Highlights

  1. Main Contacts: 3 normally open (NO) main poles with no normally closed (NC) main contacts
  2. Auxiliary Contacts: 1 built-in normally closed (NC) auxiliary contact with no normally open (NO) auxiliary contacts
  3. Rated Operational Voltage: 690 V AC for both main and auxiliary circuits
  4. Rated Frequency: 50 / 60 Hz for both main and auxiliary circuits
  5. Rated Control Circuit Voltage: 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz
  6. Rated Operational Current AC-3: 32 A at 380 / 400 V, 415 V, 440 V, and 220 / 230 / 240 V, 28 A at 500 V, and 21 A at 690 V
  7. Rated Operational Power AC-3: 15 kW at 380 / 400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220 / 230 / 240 V
  8. Rated Operational Current AC-1: 55 A at 220 / 240 V and 690 V, and 39 A at 690 V at 70 °C
  9. Conventional Free-air Thermal Current (Ith): 65 A per IEC 60947-4-1 and 16 A per IEC 60947-5-1 at 40 °C
  10. Rated Short-time Withstand Current (Icw): 600 A for 1 s, 400 A for 10 s, 225 A for 30 s, 150 A for 1 min, and 65 A for 15 min at 40 °C in free air from a cold state
  11. Maximum Breaking Capacity: 820 A at 440 V and 340 A at 690 V
  12. Maximum Electrical Switching Frequency: 1200 cycles per hour for AC-3 and AC-15, 600 cycles per hour for AC-1, and 900 cycles per hour for DC-13
  13. Maximum Mechanical Switching Frequency: 3600 cycles per hour
  14. Rated Insulation Voltage (Ui): 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C)
  15. Rated Impulse Withstand Voltage (Uimp): 6 kV for the auxiliary circuit
  16. Operate Time: NC contact closing 7 to 14 ms and NO contact opening 4 to 11 ms after coil de-energization, NC contact opening 6 to 18 ms and NO contact closing 8 to 21 ms after coil energization
  17. Degree of Protection: IP20 for main, auxiliary, and coil terminals per IEC 60529, IEC 60947-1, and EN 60529
  18. Terminal Type: Screw terminals
  19. General Use Rating UL/CSA: 50 A at 600 V AC
  20. Horsepower Rating UL/CSA: 3 hp at 120 V AC single phase, 7.5 hp at 240 V AC single phase, 10 hp at 200 to 240 V AC three phase, 25 hp at 440 to 480 V AC three phase, and 30 hp at 550 to 600 V AC three phase
  21. Tightening Torque UL/CSA: 9 in·lb for auxiliary and control circuits and 20 in·lb for the main circuit
  22. Ambient Air Temperature: -40 to 70 °C without thermal overload relay, -25 to 55 °C with thermal overload relay, and -60 to +80 °C for storage
  23. Maximum Operating Altitude: 3000 m without derating
  24. Dimensions and Weight: 54 mm width, 90 mm depth/length, 108.3 mm height, and 0.667 kg net weight
  25. Compliance: CB, CCC, and CE declarations
AX32-30-01-88

Product Information

Technical Specifications

Specifications for AX32-30-01-88

ParameterValue
Product Net Width54 mm
Product Net Depth / Length90 mm
Product Net Height108.3 mm
Product Net Weight0.667 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC1
Rated Operational VoltageAuxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 5060 Hz Main Circuit 5060 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)(220 / 240 V) 55 °C 55 A (690 V) 40 °C 55 A (690 V) 70 °C 39 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 32 A (440 V) 55 °C 32 A (500 V) 55 °C 28 A (690 V) 55 °C 21 A (380400 V) 55 °C 32 A (220230240 V) 55 °C 32 A
Rated Operational Power AC-3 (Pe)(415 V) 15 kW (440 V) 18.5 kW (500 V) 18.5 kW (690 V) 18.5 kW (380400 V) 15 kW (220230240 V) 9 kW
Rated Operational Current AC-15 (Ie)(500 V) NC 2 (500 V) 2 A (690 V) 2 A (24127 V) 6 A (220240 V) 4 A (380400 V) 3 A (400440 V) 2 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A for 0.1 s 140 A for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour (AC-15) 1200 cycles per hour (AC-3) 1200 cycles per hour (DC-13) 900 cycles per hour
ParameterValue
Rated Operational Current DC-13 (Ie)(24 V) 6 A144 W (110 V) 0.55 A60 W (125 V) 1.1 A138 W (220 V) 0.55 A121 W (250 V) 0.55 A138 W (400 V) 2.8 A134 W (500 V) 2 A144 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 230 ... 240 V 60 Hz 240 ... 260 V
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 14 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil Energization and NC Contact Opening 6 ... 18 ms Between Coil Energization and NO Contact Closing 8 ... 21 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal TypeScrew Terminals
General Use Rating UL/CSA(600 V AC) 50 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 3 hp (200 ... 208 V AC) Three Phase 10 hp (220 ... 240 V AC) Three Phase 10 hp (240 V AC) Single Phase 7.5 hp (440 ... 480 V AC) Three Phase 25 hp (550 ... 600 V AC) Three Phase 30 hp
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb Control Circuit 9 in·lb Main Circuit 20 in·lb
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C Close to Contactor without Thermal O/L Relay -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SBL281074R8801