- AX32-30-10-86
The ABB AX32-30-10-86 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, 220/230/240 V, and 28 A at 500 V, and 21 A at 690 V, all at 55 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, and 18.5 kW at 440 V, 500 V, and 690 V. Coil control voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; net weight 0.667 kg. Terminals are screw type, IP20.
- AX32-30-10-88
The ABB AX32-30-10-88 is a block-type AC contactor with three normally open main contacts and one normally open auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, and operates at 50 or 60 Hz. The rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C, and 21 A at 690 V at 55 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, and 18.5 kW at 440 V, 500 V, and 690 V. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high, with a net weight of 0.667 kg. Terminals are screw type.
- AX370-30-11-81
The ABB AX370-30-11-81 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 4.7 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 600 A at 690 V and 40 °C, 500 A at 55 °C, and 400 A at 70 °C. Rated operational current AC-3 is 370 A at 415 V and 55 °C, and 315 A at 500 V and 55 °C. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C).
- AX370-30-11-83
The ABB AX370-30-11-83 is a 3-pole AC-operated contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Its main circuit is rated 1000 V at 60 Hz, with a rated control circuit voltage of 48 V at both 50 Hz and 60 Hz. Rated operational current AC-3 is 370 A at 415 V, 440 V, and 380/400 V, all at 55 °C. Rated operational power AC-3 is 200 kW at 415 V, 440 V, and 380/400 V. Conventional free-air thermal current is 250 A per IEC 60947-4-1 for open contactors at 40 °C. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 4.7 kg.
- AX370-30-11-84
The ABB AX370-30-11-84 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 1000 V in the main circuit at 50 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V and 55 °C, with rated operational power AC-3 of 200 kW at 415 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C); rated impulse withstand voltage is 8 kV. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 4.7 kg.
- AX370-30-11-85
The ABB AX370-30-11-85 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 4.7 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 220/230/240 V, 380/400 V, 415 V, and 440 V, and 315 A at 500 V and 690 V, all at 55 °C. Rated operational power AC-3 is 200 kW at 415 V and 440 V, 250 kW at 500 V, and 315 kW at 690 V. Maximum electrical switching frequency is 300 cycles per hour.
- AX370-30-11-86
ABB AX370-30-11-86 AC contactor, manufacturer ID 1SFL607074R8611. It has 3 NO main contacts and 1 NO plus 1 NC auxiliary contact. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 250 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 220/230/240 V, 380/400 V, 415 V, and 440 V at 55 °C, and 315 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 includes 110 kW at 220/230/240 V, 200 kW at 380/400 V, 415 V, and 440 V, 250 kW at 500 V, and 315 kW at 690 V. Maximum electrical switching frequency is 300 cycles per hour. Dimensions are 140 mm wide, 180 mm deep, 225 mm high; weight 4.7 kg.
- AX370-30-11-88
The ABB AX370-30-11-88 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 4.7 kg. The main circuit is rated 1000 V at 60 Hz. Conventional free-air thermal current is 250 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 370 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, and 315 A at 500 V and 690 V, all at 55 °C. Maximum electrical switching frequency is 300 cycles per hour. Rated impulse withstand voltage is 8 kV.