- AX32-30-10-75
The ABB AX32-30-10-75 is an AC contactor with three main NO poles and one built-in auxiliary NO contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V and 21 A at 690 V, both at 55 °C; rated operational power AC-3 is 15 kW at 415 V and 18.5 kW at 690 V. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high, weighing 0.667 kg. Terminals are screw type. The coil operates at 200 V 50 Hz or 200 to 220 V 60 Hz. Maximum mechanical switching frequency is 3600 cycles per hour.
- AX32-30-10-80
The ABB AX32-30-10-80 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 54 mm wide, 90 mm deep, and 108.3 mm high, and weighs 0.667 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, and 21 A at 690 V. Rated operational power AC-3 is 15 kW at 415 V and 380/400 V, and 18.5 kW at 440 V, 500 V, and 690 V. The control circuit voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Terminals are screw type, IP20.
- AX32-30-10-81
The ABB AX32-30-10-81 is an AC contactor with three main poles (3 NO, 0 NC) and one built-in auxiliary contact (1 NO, 0 NC). It has a rated operational voltage of 690 V for both main and auxiliary circuits, and a rated frequency of 50/60 Hz. The rated control circuit voltage is 24 V at 50 Hz and 24 V at 60 Hz. Rated operational current AC-3 is 32 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, and 21 A at 690 V. Rated operational power AC-3 is 15 kW at 415 V and 380/400 V, and 18.5 kW at 440 V, 500 V, and 690 V. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high, with a net weight of 0.667 kg. Terminals are screw type.
- AX32-30-10-83
The ABB AX32-30-10-83 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50 or 60 Hz. Rated operational current AC-3 is 32 A at 415 V and 55 °C, 28 A at 500 V and 55 °C, and 21 A at 690 V and 55 °C. Rated operational power AC-3 is 15 kW at 415 V and 18.5 kW at 500 V and 690 V. The coil is rated 48 V at 50 Hz and 60 Hz. Terminals are screw type, IP20. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high, with a net weight of 0.667 kg.
- AX32-30-10-84
The ABB AX32-30-10-84 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, and 21 A at 690 V, all at 55 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, and 18.5 kW at 440 V, 500 V, and 690 V. The coil operates at 110 V 50 Hz or 110 to 120 V 60 Hz. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; net weight is 0.667 kg.
- AX32-30-10-85
ABB AX32-30-10-85 AC contactor, manufacturer ID 1SBL281074R8510. Block-type contactor with 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NO. Rated operational voltage is 690 V for both main and auxiliary circuits, with rated frequency 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, 220/230/240 V, and 28 A at 500 V, 21 A at 690 V, all at 55 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Coil voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Dimensions are 54 mm width, 90 mm depth, 108.3 mm height; net weight 0.667 kg. Screw terminals, IP20.
- AX32-30-10-86
The ABB AX32-30-10-86 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, 220/230/240 V, and 28 A at 500 V, and 21 A at 690 V, all at 55 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, and 18.5 kW at 440 V, 500 V, and 690 V. Coil control voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; net weight 0.667 kg. Terminals are screw type, IP20.
- AX32-30-10-88
The ABB AX32-30-10-88 is a block-type AC contactor with three normally open main contacts and one normally open auxiliary contact. It has a rated operational voltage of 690 V for both main and auxiliary circuits, and operates at 50 or 60 Hz. The rated control circuit voltage is 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C, and 21 A at 690 V at 55 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, and 18.5 kW at 440 V, 500 V, and 690 V. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high, with a net weight of 0.667 kg. Terminals are screw type.