- AX32-30-01-80
The ABB AX32-30-01-80 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. The control circuit is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Main and auxiliary circuits are rated 690 V at 50 or 60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, and 21 A at 690 V, all at 55 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, and 18.5 kW at 440 V, 500 V, and 690 V. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; net weight is 0.667 kg. Terminals are screw type, IP20.
- AX32-30-01-81
ABB AX32-30-01-81 AC contactor, manufacturer ID 1SBL281074R8101. Three main contacts NO, zero main contacts NC, one auxiliary contact NC. Rated operational voltage 690 V for both main and auxiliary circuits, rated frequency 50/60 Hz. Coil voltage 24 V at 50 Hz and 24 V at 60 Hz. Rated operational current AC-3: 32 A at 415 V, 32 A at 440 V, 28 A at 500 V, and 21 A at 690 V, all at 55 °C. Rated operational power AC-3: 15 kW at 415 V, 18.5 kW at 440 V, 18.5 kW at 500 V, and 18.5 kW at 690 V. Dimensions 54 mm wide, 90 mm deep, 108.3 mm high; net weight 0.667 kg. Screw terminals, IP20 at main, auxiliary, and coil terminals. Maximum operating altitude 3000 m without derating.
- AX32-30-01-83
The ABB AX32-30-01-83 is an AC contactor with three normally open main contacts and one normally closed auxiliary contact. Its coil is rated 48 V at 50 Hz and 60 Hz. Rated operational voltage is 690 V for both main and auxiliary circuits, with rated frequency 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, 220/230/240 V, and 28 A at 500 V, and 21 A at 690 V, all at 55 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Dimensions are 54 mm width, 90 mm depth, and 108.3 mm height; net weight 0.667 kg. Terminals are screw type, IP20.
- AX32-30-01-84
ABB AX32-30-01-84 AC contactor, block-type, with 3 main poles (NO) and 1 built-in auxiliary contact (NC). Coil: 110 V at 50 Hz, 110 to 120 V at 60 Hz. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz. Rated operational current AC-3: 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 28 A at 500 V, 21 A at 690 V, all at 55 °C. Rated operational power AC-3: 15 kW at 380/400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, 9 kW at 220/230/240 V. Dimensions 54 x 90 x 108.3 mm; net weight 0.667 kg. Screw terminals; IP20 at main, auxiliary, and coil terminals.
- AX32-30-01-85
ABB AC contactor, display model AX32-30-01-85, manufacturer ID 1SBL281074R8501. It has three main poles (3 NO, 0 NC) and one auxiliary NC contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V (55 °C), 28 A at 500 V, and 21 A at 690 V. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Control circuit voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. Dimensions are 54 mm wide, 90 mm deep, and 108.3 mm high; net weight 0.667 kg. Screw terminals, IP20.
- AX32-30-01-86
The ABB AX32-30-01-86 is a 3-pole AC contactor with three normally open main contacts and one normally closed auxiliary contact. It has screw terminals and measures 54 mm wide, 90 mm deep, and 108.3 mm high, weighing 0.667 kg. The rated operational voltage is 690 V for both main and auxiliary circuits, at 50 or 60 Hz. The rated control circuit voltage is 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz. Rated operational current AC-3 is 32 A at 415 V and 440 V, and rated operational power AC-3 is 15 kW at 415 V. Maximum operating altitude without derating is 3000 m.
- AX32-30-01-88
ABB AX32-30-01-88 AC contactor, manufacturer ID 1SBL281074R8801. Three main contacts NO, zero main contacts NC, one auxiliary contact NC. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz. Rated operational current AC-3: 32 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, each at 55 °C; 28 A at 500 V and 21 A at 690 V, each at 55 °C. Rated operational power AC-3: 15 kW at 380/400 V and 415 V; 18.5 kW at 440 V, 500 V, and 690 V; 9 kW at 220/230/240 V. Rated control circuit voltage: 230 to 240 V at 50 Hz, 240 to 260 V at 60 Hz. Screw terminals. Dimensions 54 mm width, 90 mm depth, 108.3 mm height; net weight 0.667 kg.
- AX32-30-10-26
The ABB AX32-30-10-26 is an AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 54 mm wide, 90 mm deep, and 108.3 mm high, and weighs 0.667 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 65 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 32 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C).