Product Model
PST105-690-70T
Material Number
1SFA895009R7020
Manufacturer
ABB
Product ID
90323

Get a Free Quote

Request pricing and availability for PST105-690-70T.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
13 kg
Rated Operational Voltage
Main Circuit 400 ... 690 V AC
Rated Control Supply Voltage (Us)
100 ... 250 V AC
Rated Frequency (f)
50/60 Hz Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)
(400 V) 55 kW (500 V) 75 kW (690 V) 90 kW
Rated Operational Current - In-Line Connection (Ie)
105 A
See all specifications

Product Highlights

  1. Rated Operational Voltage: Main circuit 400 to 690 V AC at 50/60 Hz
  2. Rated Operational Current: 105 A in-line connection and 181 A inside delta connection
  3. Rated Operational Power: In-line 55 kW at 400 V, 75 kW at 500 V, and 90 kW at 690 V, inside delta 90 kW at 400 V, 110 kW at 500 V, and 160 kW at 690 V
  4. Starting Capability: 3xIe for 15 s, current limit 1.5 to 7xIe, initial voltage 30 to 70 percent, and ramp time 1 to 120 s
  5. Protection and Control: Built-in electronic overload protection with adjustable rated motor current 30 to 115 percent, service factor 115 percent, and run, bypass, fault, and overload signal relays
  6. Communication and I/O: FieldBusPlug standard, analog outputs 0 to 10 V, 0 to 20 mA, and 4 to 20 mA, and LED indications for ready to start/standby, protection, and fault
  7. Terminal and Mounting Data: Main circuit bars with 8.5 mm hole diameter and 17.5 x 5 mm width and thickness, control and supply circuit rigid conductors up to 2.5 mm², tightening torque 18 N·m main and 0.5 N·m control/supply
  8. Ambient Conditions: Operation 0 to +50 °C and storage -25 to +70 °C
PST105-690-70T

Product Information

Technical Specifications

Specifications for PST105-690-70T

ParameterValue
Product Net Width186 mm
Product Net Height390 mm
Product Net Depth / Length270 mm
Product Net Weight13 kg
Rated Operational VoltageMain Circuit 400 ... 690 V AC
Rated Control Supply Voltage (Us)100 ... 250 V AC
Rated Control Circuit Voltage (Uc)DC Operation 24 V
Rated Frequency (f)50/60 Hz Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)(400 V) 55 kW (500 V) 75 kW (690 V) 90 kW
Rated Operational Current - In-Line Connection (Ie)105 A
Rated Operational Power - Inside Delta Connectionat 400 V 90 kW at 500 V 110 kW at 690 V 160 kW
Rated Operational Current - Inside Delta Connection181 A
Service Factor Percentage115 %
Overload ProtectionBuild-in electronic overload protection
Integrated Electronic OverloadYes
Adjustable Rated Motor Current Ie30 ... 115 %
Starting Capacity at Maximum Rated Current Ie3xIe for 15s
Ramp Time0 ... 120 second [unit of time] 1 ... 120 second [unit of time]
Initial Voltage During Start30 ... 70 %
Step Down Voltage Special Ramp100 ... 30 %
Current Limit Function1.5 ... 7xIe
ParameterValue
Switch for Inside Delta ConnectionYes
Run Signal RelayYes
By-pass Signal RelayYes
Fault Signal RelayYes
Overload Signal RelayYes
Analog Outputs0…10 volts 0…20 mA 4…20 mA
Signal Indication Ready to Start/Standby ON (LED)Green
Signal Indication Protection (LED)Yellow
Signal Indication Fault (LED)Red
Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time30
CommunicationFiledBusPlug(Standard)
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars
Connecting Capacity Main CircuitHole Diameter 8.5 mm Width and Thickness 17.5x5 mm
Connecting Capacity Control CircuitRigid 1 x 2.5 mm² Rigid 2 x 1.5 mm²
Connecting Capacity Supply CircuitRigid 1 x 2.5 mm²
Tightening TorqueControl Circuit 0.5 N·m Main Circuit 18 N·m Supply Circuit 0.5 N·m
Product Main TypePST105
Ambient Air TemperatureOperation 0 ... +50 °C Storage -25 ... +70 °C
Object Classification CodeQ
ETIM 7EC000640 - Soft starter
ETIM 8EC000640 - Soft starter
ETIM 9EC000640 - Soft starter
eClassV11.0 : 27370907
Manufacturer ID1SFA895009R7020

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.