- PST142-690-70T
ABB PST142-690-70T softstarter, manufacturer ID 1SFA895010R7020, is a spare part in the softstarters spare parts category. Main circuit rated operational voltage is 400 to 690 V AC at 50/60 Hz. Rated control supply voltage is 100 to 250 V AC; rated control circuit voltage is 24 V DC. In-line connection ratings are 142 A and 75 kW at 400 V, 90 kW at 500 V, and 132 kW at 690 V. Inside delta connection ratings are 245 A and 132 kW at 400 V, 160 kW at 500 V, and 220 kW at 690 V. Built-in electronic overload protection is included, with adjustable rated motor current 30 to 115 percent. Dimensions are 186 mm wide, 390 mm high, and 270 mm deep; net weight is 13 kg.
- PST175-600-70
ABB PST175-600-70 soft starter, manufacturer ID 1SFA894011R7000, product main type PST175. In-line connection ratings: 175 A, 90 kW at 400 V and 110 kW at 500 V. Inside delta connection ratings: 300 A, 160 kW at 400 V and 200 kW at 500 V. Main circuit rated operational voltage 208 to 600 V AC, 50/60 Hz. Rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70 percent, current limit 1.5 to 7xIe. Dimensions 360 x 420 x 270 mm, 21.5 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529. Ambient operation 0 to +50 degrees C.
- PST175-600-70T
The ABB PST175-600-70T soft starter is a spare part for motor control. Its main circuit is rated 208 to 600 V AC at 50/60 Hz, with a rated operational current of 175 A in in-line connection and 300 A in inside-delta connection. In-line rated operational power is 90 kW at 400 V and 110 kW at 500 V; inside-delta power is 160 kW at 400 V and 200 kW at 500 V. Control supply voltage is 100 to 250 V AC, and control circuit voltage is 24 V DC. It includes built-in electronic overload protection, adjustable motor current from 30 to 115 percent, a service factor of 115 percent, and starting capacity of 3xIe for 15 s. Dimensions are 360 mm wide, 420 mm high, and 270 mm deep; net weight is 21.5 kg.
- PST175-690-70
ABB PST175-690-70 softstarter, manufacturer ID 1SFA895011R7000. Rated operational voltage main circuit 400 to 690 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: 175 A, 90 kW at 400 V, 110 kW at 500 V, 160 kW at 690 V. Inside delta connection: 300 A, 160 kW at 400 V, 200 kW at 500 V, 257 kW at 690 V. Adjustable rated motor current 30 to 115%, service factor 115%, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70%. Built-in electronic overload protection. Dimensions 360 x 420 x 270 mm, 21.5 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529. Ambient operation 0 to +50 °C.
- PST175-690-70T
ABB PST175-690-70T softstarter, manufacturer ID 1SFA895011R7020. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz. Rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: 175 A rated operational current, with rated operational power of 90 kW at 400 V, 110 kW at 500 V, and 160 kW at 690 V. Inside delta connection: 300 A, with 160 kW at 400 V, 200 kW at 500 V, and 257 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70 percent. Coated PCB assembly. Dimensions 360 x 420 x 270 mm; net weight 21.5 kg.
- PST210-600-70
ABB PST210-600-70 soft starter, manufacturer ID 1SFA894012R7000. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz. Rated operational current in-line connection 210 A; inside delta connection 360 A. Rated operational power in-line connection 110 kW at 400 V and 132 kW at 500 V; inside delta connection 184 kW at 400 V and 250 kW at 500 V. Rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent. Starting capacity 3xIe for 15 s. Ramp time 0 to 120 s. Current limit 1.5 to 7xIe. Dimensions 360 x 420 x 270 mm; net weight 21.5 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529. Ambient operating temperature 0 to +50 degrees C.
- PST210-690-70
ABB PST210-690-70 soft starter, manufacturer ID 1SFA895012R7000. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz. In-line connection: rated operational current 210 A, rated operational power 110 kW at 400 V, 132 kW at 500 V, and 184 kW at 690 V. Inside delta connection: 360 A, with 184 kW at 400 V, 250 kW at 500 V, and 315 kW at 690 V. Control supply voltage 100 to 250 V AC; control circuit voltage 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70 percent. Dimensions 360 x 420 x 270 mm; net weight 20 kg.
- PST210-690-70T
Product identification: ABB PST210-690-70T. ABB PST210 soft starter, manufacturer ID 1SFA895012R7020, for in-line or inside-delta motor starting. In-line ratings: 210 A, 110 kW at 400 V, 132 kW at 500 V, and 184 kW at 690 V. Inside-delta ratings: 360 A, 184 kW at 400 V, 250 kW at 500 V, and 315 kW at 690 V. Main circuit voltage is 400 to 690 V AC at 50/60 Hz. Control supply is 100 to 250 V AC; control circuit is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a 115 percent service factor. Starting capacity is 3xIe for 15 s. Ramp time is 1 to 120 s; initial voltage is 30 to 70 percent. Dimensions are 360 mm wide, 420 mm high, and 270 mm deep; net weight is 21.5 kg.