- PST250-600-70
ABB PST250-600-70 softstarter, manufacturer ID 1SFA894013R7000. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: rated operational current 250 A, rated operational power 132 kW at 400 V and 160 kW at 500 V. Inside delta connection: 430 A, 220 kW at 400 V and 295 kW at 500 V. Adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s. Ramp time 1 to 120 s, initial voltage 30 to 70 percent, step-down voltage 100 to 30 percent. Built-in electronic overload protection. Dimensions 360 x 420 x 270 mm, 23 kg.
- PST250-690-70
ABB PST250-690-70 softstarter, manufacturer ID 1SFA895013R7000, product main type PST250. Main circuit rated operational voltage is 400 to 690 V AC at 50/60 Hz. Rated operational current in in-line connection is 250 A, with rated operational power of 132 kW at 400 V, 160 kW at 500 V, and 220 kW at 690 V. Inside delta connection ratings are 430 A, with 220 kW at 400 V, 295 kW at 500 V, and 400 kW at 690 V. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a 115 percent service factor. Starting capacity is 3xIe for 15 s. Ramp time is 0 to 120 s. Dimensions are 360 mm width, 420 mm height, and 270 mm depth; net weight is 23 kg.
- PST250-690-70T
ABB PST250-690-70T softstarter, manufacturer ID 1SFA895013R7020, is a spare part in the PST250 product main type. It measures 360 mm wide, 420 mm high, and 270 mm deep, weighing 23 kg. The main circuit is rated 400 to 690 V AC at 50/60 Hz, with control supply voltage 100 to 250 V AC and control circuit voltage 24 V DC. In-line connection ratings are 250 A and 132 kW at 400 V, 160 kW at 500 V, and 220 kW at 690 V. Inside-delta ratings are 430 A and 220 kW at 400 V, 295 kW at 500 V, and 400 kW at 690 V. Built-in electronic overload protection is included, with adjustable rated motor current 30 to 115 percent and starting capacity 3xIe for 15 s.
- PST30-600-70
ABB PST30-600-70 softstarter, manufacturer ID 1SFA894002R7000, is a spare part in the PST30 product main type. The main circuit is rated 208 to 600 V AC at 50/60 Hz, with a rated control supply voltage of 100 to 250 V AC and a rated control circuit voltage of 24 V DC. In-line connection ratings are 30 A and 15 kW at 400 V, 18.5 kW at 500 V. Inside delta connection ratings are 52 A and 25 kW at 400 V, 30 kW at 500 V. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a service factor of 115 percent. Starting capacity is 3xIe for 15 s. Ramp time is 0 to 120 s. Dimensions are 160 mm wide, 260 mm high, 196 mm deep, weighing 4.8 kg.
- PST30-600-70T
ABB PST30-600-70T softstarter, manufacturer ID 1SFA894002R7020. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz. Rated operational current 30 A in-line connection, with rated operational power 15 kW at 400 V and 18.5 kW at 500 V. Inside delta connection ratings are 52 A, 25 kW at 400 V and 30 kW at 500 V. Control supply voltage 100 to 250 V AC; control circuit voltage 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70 percent, step-down voltage 100 to 30 percent. Dimensions 160 x 260 x 196 mm, 4.8 kg.
- PST30-690-70
ABB PST30-690-70 soft starter, manufacturer ID 1SFA895002R7000. Main circuit rated operational voltage 400 to 690 V AC; rated control supply voltage 100 to 250 V AC; control circuit voltage 24 V DC; rated frequency 50/60 Hz. In-line connection: rated operational current 30 A, rated operational power 15 kW at 400 V, 18.5 kW at 500 V, 25 kW at 690 V. Inside delta connection: 52 A, 25 kW at 400 V, 30 kW at 500 V, 45 kW at 690 V. Adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70 percent. Built-in electronic overload protection. Dimensions 160 x 260 x 196 mm; weight 4.8 kg.
- PST30-690-70T
ABB PST30-690-70T soft starter, manufacturer ID 1SFA895002R7020. Main circuit rated 400 to 690 V AC at 50/60 Hz; in-line rated operational current 30 A with rated operational power 15 kW at 400 V, 18.5 kW at 500 V, and 25 kW at 690 V. Inside delta connection ratings are 52 A and 25 kW at 400 V, 30 kW at 500 V, 45 kW at 690 V. Control supply voltage 100 to 250 V AC; control circuit voltage 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 0 to 120 s, current limit 1.5 to 7xIe. Screw terminals, dimensions 160 x 260 x 196 mm, 4.8 kg. Operating ambient 0 to +50 degrees C.
- PST300-600-70T
ABB PST300-600-70T softstarter, manufacturer ID 1SFA894014R7020, product main type PST300. Main circuit rated operational voltage is 208 to 600 V AC at 50/60 Hz. Rated control supply voltage is 100 to 250 V AC; rated control circuit voltage for DC operation is 24 V. In-line connection ratings are 300 A and 160 kW at 400 V, 200 kW at 500 V. Inside delta connection ratings are 515 A, 257 kW at 400 V and 355 kW at 500 V. Built-in electronic overload protection is included, with adjustable rated motor current 30 to 115 percent and service factor 115 percent. Starting capacity is 3xIe for 15 s. Ramp time is 0 to 120 s or 1 to 120 s; initial voltage during start is 30 to 70 percent. Dimensions are 360 mm width, 420 mm height, 270 mm depth; net weight 23 kg.